Air King AKLC70DRSB Operating Manual Download Page 2

INSTALLATION INSTRUCTIONS
CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.  Unpack fan from the carton and confirm that all pieces are present. In addition to the 

exhaust fan you should have:

 

 

1 - Grill with Glass Light Lens

 

 

1 - Damper Assembly (attached)

 

 

2 - #8 Screws

 

 

2 - Lockwashers

 

 

4 - Mounting Rails

 

 

1 - Instruction/Safety Sheet  

2.  Choose the location for your fan. To ensure the best air and sound performance, it 

is recommended that the length of ducting and the number of elbows be kept to a 

minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise 

and airflow restrictions. This fan will require at least 6

"

 of clearance in the ceiling or wall, 

and will mount through drywall up to 3/4

"

 thick. The fan can be mounted directly to the 

joist using the mounting tabs on the sides of the housing or between 16” on center joists 

using the 4 provided mounting rails. 

SECTION 2

New Construction

1. 

Mounting Rail Installation:

 Install the rails on the housing and position the housing next 

to the joist. Using the gauge on the fan’s housing, line up housing so that it will be flush 

with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to 

the joists and slide the housing into the final position 

(Figure 1)

.

2. 

Mounting Tab Installation: 

Using the gauge on the fan’s housing, line up housing so 

that it will be flush with the finished ceiling. Position the fan so that the tabs rest flat 

against the joist and secure with four nails or screws (not provided) to ensure proper 

installation 

(Figure 2)

.

SECTION 3

Existing Construction

1a. 

Mounting Rail Installation:

 Set housing in position between the joist and trace an outline 

onto the ceiling material 

(Figure 3).

 Set housing aside and cut opening, being careful not 

to cut or damage any electrical or other hidden utilities. Install the rails on the housing and 

position the housing in the previously cut hole so that it is flush with the finished ceiling. 

Secure the ends of the rails to the joists with nails or screws (not provided) 

(Figure 1).

www.airkinglimited.com

A210572216 Rev. A 5-14

2 of 4

1b. 

Mounting Tab Installation:

 Position housing against the joist and trace an outline of the 

housing onto the ceiling material 

(Figure 4).

 Set housing aside and cut opening, being 

careful not to cut or damage any electrical or other hidden utilities. Place housing next 
to the joist and insure that it is flush with the finished ceiling. Secure with four nails or 
screws (not provided) to ensure proper installation 

(Figure 2).

SECTION 4

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

1.  Connect the ducting to the fan’s duct collar 

(Figure 5)

. Secure in place using tape or 

screw clamp. Always duct the fan to the outside through a wall or roof cap.

NOTE:

 If damper detaches from unit, reattach by snapping the collar back onto the unit. It is 

designed to only fit one way.

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE 

WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE 
UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE 
SERVICES OF A QUALIFIED ELECTRICIAN.

NOTE:

 This unit includes a side access panel for wiring that does not require the removal of the 

fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the 
blower assembly and internal wiring compartment. Both methods are equally effective.

1a. 

External Wire Compartment:

 Remove the wire compartment cover screw and place 

cover in a secure place 

(Figure 6)

.

Housing

Joist

Mounting Rails

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

5/8"

1/2"
1/4"

3/8"

Summary of Contents for AKLC70DRSB

Page 1: ...ation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper comb...

Page 2: ...aside and cut opening being careful not to cut or damage any electrical or other hidden utilities Install the rails on the housing and position the housing in the previously cut hole so that it is flu...

Page 3: ...ite wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the red wire from the fan s light receptacle and the b...

Page 4: ...reinstalling Refer to instructions in Section 6 Completing the Installation to reinstall grill and glass light lens 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan...

Page 5: ...ot cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL W...

Page 6: ...nal Wire Cover 5S2299014 3 1 Collar Damper 5S1299111 4 1 Gasket Collar 5S2299015 5 1 Interior Wire Cover 5S2234001 6 1 Connector 5S1299008 Qty Description Replacement Part 7 1 Polarized Receptacle 5S1...

Page 7: ...es personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et...

Page 8: ...sis de c t et d couper l ouverture en prenant soin de ne pas couper ou endommager des c bles lectriques dissimul s ou autres utilit s Installer les traverses sur le ch ssis et positionner le ch ssis d...

Page 9: ...de jonction du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du r ceptacle de la lumi re et le fil blanc du r ceptacle du ventilateur d vacuation Raccorder le fil noir...

Page 10: ...r Vous r f rer la Section 6 Compl ter l installation pour r installer la grille les lentilles en verre 2 Nettoyage de l assemblage du ventilateur Nettoyer toutes les parties l aide d un chiffon sec ou...

Page 11: ...pas s appliquer La pr sente garantie vous donne des droits l gaux sp cifiques et peut tre certains autres droits qui peuvent varier selon la province La preuve d achat est exig e avant qu une r clamat...

Page 12: ...3 1 Collet clapet 5S1299111 4 1 Joint collet 5S2299015 5 1 Couvercle de c ble Interne 5S2234001 6 1 Connector 5S1299008 de pi ce Qte Description de remplacement 7 1 Polarized r ceptacle 5S1999001 8 1...