background image

1b.  Internal Wire Compartment: Remove the screw holding the venturi in place. Lift the 

venturi up and at an angle to slide it out of the housing 

(Figure 7).

 Remove the wire 

compartment cover screw and place the cover in a secure place 

(Figure 8).

NOTE:

 If the fan motor plug is 

connected to the fan housing 

receptacle, unplug so the blower 

assembly can be completely removed.

2. 

Run wiring from an approved wall switch carrying the appropriate rating. One neutral 

(white), one ground (green or bare copper), and one hot (black lead connected to the switch). 

Secure the electrical wires to the housing with an approved electrical connector. Make sure 

you leave enough wiring in the box to make the connection to the fan’s receptacle.

3. 

From where you have chosen to access the fan’s junction box, connect the White wire 

from the house to the White wire from the fan’s receptacle. Connect the Black wire from 

the wall switch to the Black wire from the fan’s receptacle. Connect the ground wire 

from the house to the Green wire from the fan’s receptacle 

(Figure 9)

. Use approved 

methods for all connections.

NOTE:

 The fan’s receptacle wires might need to be pulled outside compartment for connection. 

Only pull the three loose wires outside of compartment. Additional wires will be present.

4. 

Carefully tuck wire back inside wire compartment and replace wire compartment cover 

securing with the screw that was removed earlier.

www.airkinglimited.com

A210952009 Rev. Q 4-16

3 of 8

SECTION 6

Completing the Installation

1.  Use a sealant appropriate for contact with the building materials present and for the 

temperature requirements of the installation to prevent air leakage from unconditioned 

spaces is recommended. If gaps between unit housing and ceiling are great, additional 

material (backing rod, ceiling material) may be required.

NOTE:

 This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan 

be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.

2. 

If the fan’s blower assembly was removed during the wiring process, reinstall the 

blower by reversing the directions in 

Section 5

 (Wiring), 

Step 1b.

 

3. 

Plug the fan’s quick connect motor cord into the receptacle. This cord will only fit one 

way into the receptacle 

(Figure 10).

4. 

Install the grill by squeezing the two ends of the springs together and installing them up 

into the slots on the fan’s housing. Push the grill up into position 

(Figure 11).

5. 

Restore power and test your installation.

SECTION 7

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such as dishwashing liquid, 

and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. 

Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Finishing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

CALIFORNIA RESIDENTS ONLY:

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR 

CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL 

[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE 

REPRODUCTIVE TOXICITY.

Figure 6

Screw

Wire 

Compartment 

Cover

Figure 9

Supply from 

house

Ground

White

Hot (Black)

Figure 8

Screw

Wire 

Compartment 

Cover

Plug

Figure 7

Venturi

Screw

Figure 11

Figure 10

Summary of Contents for AK50S

Page 1: ...g equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidde...

Page 2: ... airkinglimited com A210952009 Rev Q 4 16 2 of 8 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performa...

Page 3: ...n to prevent air leakage from unconditioned spaces is recommended If gaps between unit housing and ceiling are great additional material backing rod ceiling material may be required NOTE This fan is rated for direct insulation contact Type IC and it is recommended that this fan be completely covered by insulation in order to reduce heat loss or gain to unconditioned space 2 If the fan s blower ass...

Page 4: ...you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 4pm Eas...

Page 5: ...abricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de coupe ou de perçage des murs et plafonds ne pas endommager le filage électrique et autres utilités cachées ATTENTION ...

Page 6: ...E MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit et la consommation d énergie du ventilateur Utilisez la route de canalisation la plus courte et la plus droite possible pour une meilleure performance et évitez d ins...

Page 7: ...riel supplémentaire tige de support matériel de plafond peut être nécessaire REMARQUE Ce ventilateur est conçu pour le contact d isolation directe type IC Il est aussi recommandé que ce ventilateur soit complètement recouvert par l isolation afin de réduire la perte de chaleur ou de gagner de l espace inconditionné 2 Si l assemblage de la soufflante du ventilateur a été enlevé durant le processus ...

Page 8: ... CLIENTÈLE Sans frais 800 465 7300 Notre équipe de service à la clientèle est disponible pour vous aider avec des questions sur le produit les adresses des centres de service et les pièces de rechange Vous pouvez la rejoindre du lundi au vendredi de 8h 00 à 16h 00 HNE Veuillez avoir le numéro du modèle disponible ainsi que le genre et le style qui se trouvent sur l étiquette à l intérieur de votre...

Reviews: