background image

corresponding power is from 17-19W (L), 19-23W (M), 23-27W (S) to 27-30W (H). 

 

7.

 

AUTO OFF: Settings from 1- 24 hours. 0 means cancelling the settings. 3 seconds after your 

settings, the timer function will be  counted down to work by minutes and will display with 

current humidity by turns for 5 seconds if having set the humidity level.   

 

8.

 

HUMIDISTAT:  Settings  from  40  -95RH%  by  5RH%.  0  means  cancelling  the  settings.  3 

seconds after your settings, the humidistat works. It stops when the current humidity is more 

than the setting level, but the fan motor will keep working for 5 minutes. And will operate 

when the current humidity is 2RH% less than the setting level. 

 

9.

 

ANION:  When  the  machine  stands  by,  press  the  ANION  button,  it  works  whatever  it  is 

humidifying.  The  fan  motor  works  at  the  same  time.  If  it  is  not  humidifying,  when  the 

ANION is off, the fan motor stops. But if it is humidifying, when the ANION is off, the fan 

motor still works.           

 

10.

 

Protection when waterless: When the tank is out of water, the Waterless lamp is on. And the 

machine  stops.  Then  the  settings  of  TIMER  and  HUMIDISTAT  will  be  cancelled.  When 

filling the water, it should be reset for the functions. 

 

 

*Trouble Shooting Guide 

Any trouble found in normal operation, please kindly refer to the following points: 

 

Trouble   

Possible reasons   

Shooting Way 

LED display is off 

No power supply 

Connect power supply 

Not press ON   

Switch on 

LED  display  is  on,  no  mist  no 

wind 

No water in water tank 

Fill water into water tank 

Too  much  water  in  the  water 

basin 

Pull  out  some  water  from  the 

water  basin,  closed  the  cover  of 

water tank tightly. 

LED  display  is  on,  no  mist  but 

with wind 

Mist output is set on the lowest 

level 

Adjust the mist output 

LED  display  is  on,  with  water 

but shows waterless 

Floater is interrupted 

Waver the floater, keep it free   

 

 

Abnormal smell mist   

New unit 

Take out water tank, open cover, 

let  it  stays  12  hours  in  cool 

position   

Dirty water or long time staying 

water   

Cleaning water tank, fill in clear 

water 

 

 

Mist fog is too small 

Too  much  scale  in  the  water 

basin 

Clean transducer 

Water is too dirty or water kept 

too long time in the tank 

Clean  water  tank,  change  to 

fresh clear water 

Water is too cold 

Add some warm water inside 

 

Abnormal noise 

Resonant  in  water  tank  when 

water is too lower 

Fill water tank with water   

Reviews: