Air Force Pro™ Linear Air Pump 

Oil-Less Compressor 

Operation & Maintenance Manual 

IMPORTANT

:   

PLEASE READ THIS MANUAL COMPLETELY.   

SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE 

PROXIMITY TO THE AIR PUMP. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 

 

 

Thank you for purchasing Air Force Pro™ Linear Air Pumps. 

  It is manufactured to the highest standards using quality 

materials. Please follow all recommended maintenance, 

operational and safety instructions and you will receive   

years of trouble free service. 

Air Force Pro™ Linear Air Pump 

Oil-Less Compressor 

Operation & Maintenance Manual 

IMPORTANT

:   

PLEASE READ THIS MANUAL COMPLETELY.   

SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE 

PROXIMITY TO THE AIR PUMP. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 

 

 

Thank you for purchasing Air Force Pro™ Linear Air Pumps. 

  It is manufactured to the highest standards using quality 

materials. Please follow all recommended maintenance, 

operational and safety instructions and you will receive   

years of trouble free service. 

LINEAR AIR PUMP 

Oil-Less Compressor

Operation 

&

 Maintenance Manual

1

Summary of Contents for 15

Page 1: ...sor Operation Maintenance Manual IMPORTANT PLEASE READ THIS MANUAL COMPLETELY SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE PROXIMITY TO THE AIR PUMP Thank you for purchasing Air Force Pro Linear Air Pumps It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble ...

Page 2: ...hen retrieve it If the pump s electrical components get wet unplug the pump immediately 2 Carefully examine the air pump after installation It should NOT be plugged in if there is water present on any of the pumps parts 3 DO NOT operate if the cord or plug is damaged 4 DO NOT operate if the pump is malfunctioning dropped or damaged in any way 5 To prevent the plug or electrical outlet from getting...

Page 3: ... have sufficient room to allow for heat dissipation 5 Failure to observe cautions will cause the pump to automatically switch off until cool 6 Always unplug pump prior to servicing Grasp plug to remove cord from outlet DO NOT remove by pulling on power cord 7 DO NOT use the air pump for other than its intended use The use of attachments not recommended or not sold by Sunlight Supply Inc may cause ...

Page 4: ...electric shock Failure to follow these instructions can result in death fire or electrical shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman when the ground...

Page 5: ...ury or other serious injury It is your responsibility to operate this product at recommended duty pressure and ambient room temperature 2 For a permanently connected product This product must be connected to a grounded metallic permanent wiring system or an equipment grounding terminal or lead on the product Power Supply must conform to all required safety codes and be installed by a qualified ele...

Page 6: ...low these instructions can result in burns eye injury or other serious injury It is your responsibility to l Regularly inspect and make necessary repairs to product in order to maintain proper operation l Make sure that pressure is released from product before starting maintenance l NEVER add oil to this oil less compressor Check intake filter after first 500 hours of operation Clean filter and de...

Page 7: ... diaphragm off its place E Replace a new one by mounting the rubber studs into their position F Press the rim of the diaphragm into the ring G Secure the magnet with a new u nut and screw and put the diaphragm housing back with the four screws on Replacement part Information Model Diaphragm Service kit Air Force Pro 15 Part No 746500 Part No 746530 Figure 1 Figure 2 IMPORTANT To open upper enclosu...

Page 8: ...ROMAGNET 2 3 CHECK VALVE 4 4 WIRE STOPPER 1 5 U SHAPED COIL FRAME 1 6 VIBRATION CONTROL RUBBER 4 7 ACTIVATING ARM 1 8 DIAPHRAGM 2 9 DIAPHRAGM FRAME 2 10 U NUT 2 11 DIAPHRAGM HOUSING 2 12 L TUBE 2 13 STEEL PLATE 1 14 GASKET 1 15 LOWER HOUSING 1 16 RUBBER FEET 4 17 POWER CORD 1 Product View and Parts List 8 ...

Page 9: ...ct to change without notice Performance Allowance 5 Dimensions mm Performance Curves DB15 0 5 10 15 20 25 30 35 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746500 110 120 60 0 43 20 26 dBA 20 80 10 o C 2 54 kg 40 Product Specifications 9 ...

Page 10: ...re 3 C Remove the u nut in the center of diaphragm D Take the diaphragm off its place E Replace a new one by mounting the rubber studs into their position F Press the rim of the diaphragm into the ring G Secure the magnet with a new u nut and screw and put the diaphragm housing back with the four screws on Replacement part information Model Type Diaphragm service kit Air filter service kit Air For...

Page 11: ...CTROMAGNET 2 8 WIRE STOPPER 1 9 U SHAPED COIL FRAME 1 10 VIBRATION CONTROL RUBBER 4 11 ACTIVATING ARM 1 12 DIAPHRAGM 2 13 DIAPHRAGM FRAME 2 14 U NUT 2 15 CHECK VALVE 4 16 L TUBE 2 17 DIAPHRAGM HOUSING 2 18 CHAMBER SEAL ROUND 2 19 CHAMBER SEAL OVAL 2 20 SIDE COVER STEEL 2 21 CORD PROTECTOR 1 22 STEEL PLATE 1 23 GASKET 1 24 LOWER HOUSING 1 25 RUBBER FEET 4 26 POWER CORD 1 Product View and Parts List...

Page 12: ...ject to change without notice Allowance 5 Dimensions mm Part No Voltage VAC Frequency HZ AMP A WATT W 746505 110 120 60 1 1 45 Performance Curves DBM40 0 10 20 30 40 50 60 70 80 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz 46 dBA 20 80 20 o C 6 09 kg 40 40 40 Product Specifications 12 ...

Page 13: ...ubject to change without notice Allowance 5 Dimensions mm Performance Curves DBM60 0 20 40 60 80 100 120 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746510 110 120 60 1 7 63 47 dBA 20 80 10 o C 6 99 kg 40 60 60 Product Specifications 13 ...

Page 14: ...to change without notice Allowance 5 Dimensions mm Performance Curves DBM80 0 20 40 60 80 100 120 140 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 5 0 55 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746515 110 120 60 1 9 84 51 dBA 20 80 10 o C 7 05 kg 40 80 80 Product Specifications 14 ...

Page 15: ...LITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While we attempt to assure that the products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product review the pr...

Page 16: ...Exclusively distributed by ...

Reviews: