54
33 o x
x
★
The failure for
temperature
sensor of
indoor room
a.
The indoor room temperature
sensor loose;
b.
The indoor room temperature
sensor is failure;
c.
The indoor control board is
failure.
34 o x
★
x
The failure for
temperature
sensor of
indoor coil
temperature
a.
The indoor coil temperature
sensor loose;
b.
The indoor coil temperature
sensor is failure;
c.
The indoor control board is
failure.
36
★
★
Communication
failure between
the indoor unit
and outdoor
unit
a.
the communication cable
connect loose;
b.
the communication cable is
failure;
c.
the connection between the
filter board and the outdoor
control board is incorrect or
loose;
d.
the connection between the
filter board and the terminal is
incorrect or loose;
e.
the indoor control board is
failure;
f.
the PFC board is failure;
g.
the power board is failure;
h.
the outdoor control board is
failure.
38 o
★
★
★
Indoor
EEPROM
failure
a.
The EEPROM chip loose;
b.
The indoor control board is
failure
39 o x
★
★
Indoor fan
motor run
abnormally
a.
There are something block
the indoor fan motor;
b.
The fan motor cord connect
loose;
c.
The fan motor is failure;
d.
The indoor control board is
failure
41
★
★
o
★
The failure for
Indoor
grounding
protective
The indoor control board is
failure
2.2 LED display
Error
code
Sleep Timer Running Remark
:★
Light
Flash x OFF
1 2 3
Content Remark
The root cause is may be one of
the following
Summary of Contents for ABXCI4H4S0
Page 15: ...15 Outdoor 1854707...
Page 20: ...20 L1 04...
Page 21: ...21 Function Instruction 1 Major general technical parameters...
Page 63: ...63 3 4...
Page 64: ...64 5...
Page 65: ...65...
Page 66: ...66 DC fan motor test point...
Page 68: ...68 6 test point Check the screw of IPM fastening...
Page 70: ...70 test point The resistance of the compressor U W V W 7 SI and N test point...