3. Electromagnetic fields (EMF) 

This Air Cleaner device meets all requirements regarding electromagnetic fields (2014/30/EU). Provided this 

device is used properly and according to the instructions in this manual, its use is safe according to current 

scientific knowledge. 

 
 

4. Before first use 

When the device is delivered, the UV-C tubes which are responsible for the disinfection of the air, are already 

inserted. You do not need to take any steps. The device is delivered ready to plug in.  

Insert the plug into a 230 Volt socket (applies in CH). You will hear the quiet sound of the air circulation fan 

inside the housing. At the inlet, as well as at the outlet you will feel a slight draft. The device is then active and 

works reliably. 

AT FIRST USE OF THE DEVICE: Until the UVC tubes are equipoised, you will smell a strange odor. This is normal 

and can take up to 5 days. 

This also applies if the UVC tubes have been exchanged. 

 
 

5. Using the device 

Air Cleaners can be used and set up flexibly and individually. Please make sure that the cable is not a tripping 

hazard and a safe stand is guaranteed. Air inlet and outlet openings should have a minimum distance of 50cm 

to the next object. 

 

The efficiency of the device depends on the position of the stand and the respective orientation. Place the Air 

Cleaner as centrally as possible. The unit sucks aerosols most effectively where they are generated. Please also 

consider the general air exchange in the room, such as ventilation systems or open doors that influence the air 

flows in the room. Consider the best operating range in a room illustrated in chapter 10. 

 

5.1 Control and monitoring light 

PLEASE NOTE: The ECO models with flow regulation have a swith-on delay of up to 15 seconds. 

This also applies if a new power level is selected. 

 

As soon as you connect the unit to the mains, the sterilization chamber and the blower switch on 

automatically. The control lamp lights up faintly in blue and after 10 to 15 seconds at the latest you will hear 

the fan slowly turning up. 

The ECO models have a knob on the bottom of the unit with a continuously variable ventilation regulation 

function. If you turn the knob all the way to the right, the fan turns to 100% power. Turning the knob to the left 

reduces the power.  

To switch off the unit, you must unplug the unit from the mains. 

 
 

6. Housing types & cleaning 

Depending on the version of the device, you have one of the following housings: painted, CDF or HPL. 

In all cases the housings can be cleaned easily considering the below points: 

 

Painted housing

: These housings can be cleaned normally with any universal cleaner. 

 

CDF Housing

: These housings can be cleane with a universal cleaer and/or with antibacterial cleaning agents. 

 

HPL Housing

: These housings can also be cleaned with chemical cleaning agents and alcohol disinfectant 

solutions. 

 

 

CAUTION 

Please make sure to disconnect the device from the power supply before starting the cleaning/disinfection 

process! 

 

 

Summary of Contents for AC-100pro

Page 1: ... AC 250pro DENTAL Instructions for Use Table of contents 1 Important information 2 Product introduction functionality 3 Electromagnetic fields EMF 4 Before first use 5 Using the device 6 Housing types cleaning 7 Maintenance 8 Troubleshooting 9 Warranty Disposal Technical changes 10 Additional information appendix ...

Page 2: ...tion from inside the device Proper use Before using the machine read these instructions for use thoroughly and completely and comply with the instructions they contain A warranty service is not applicable for damage or defects caused by non compliance with the instructions for use Keep these instructions for use close to the machine and pass them on to the nex user Keep it in a safe place for futu...

Page 3: ... with water Also do not touch the plug with wet hands Make sure that the voltage indicated on the device matches the voltage of your power outlet Do not operate the device if it has a damaged cable or plug if it does not work properly or if it has been damaged in any way The device may only be serviced by qualified service personnel Return the device to our service center for inspection repair or ...

Page 4: ...The drawn in air is led through a suction channel to the combustion chamber Inside the combustion chamber the germs are inactivated with powerful UV C light The air flows out of the combustion chamber through a shielded outlet channel and back out of the Air Cleaner in the ambient air The effectiveness of inactivation depends on the size and structure of the respective pathogen In chapter 10 you w...

Page 5: ...2 3 Cross section of AC 250 pro DENTAL devices ...

Page 6: ...they are generated Please also consider the general air exchange in the room such as ventilation systems or open doors that influence the air flows in the room Consider the best operating range in a room illustrated in chapter 10 5 1 Control and monitoring light PLEASE NOTE The ECO models with flow regulation have a swith on delay of up to 15 seconds This also applies if a new power level is selec...

Page 7: ...Unit cannot be switched on There is no air flow to be felt There is no sound to be heard Possible reasons The power cable has not been plugged into the socket properly The plug or the cable is damaged The socket used does not work You have not waited for the 15th second power on phase until the machine starts If the device still cannot be switched on please contact our service department 9 Warrant...

Page 8: ...10 Additional information appendix Germ types and their lethal dose ...

Page 9: ...ctive 2014 30 EU Electromagnetic Compatibility For detailed information on certification and directives please visit the website aircleaner ch Your opinion is important to us Please reach out with feedback or if you have any questions Air Cleaner AG Bahnstrasse 14 CH 8544 Attikon 41 52 242 77 55 info aircleaner ch ...

Page 10: ......

Reviews: