Page 10 of 26
(Vers.12.17.2018)
S
-
100 Refractory Walled Air Curtain Burner with HATZ 3H50TIC Diesel Engine
OPERATING MANUAL
HOW TO SET UP THE MACHINE
SHUT
-
DOWN
1.
Press Throttle DOWN BUTTON (lower 2nd
from right). From
Operating High
first wait for
speed to level off at
Operating Low.
2. From
Operating Low
press Throttle DOWN
BUTTON and wait for speed to level off at
1700 RPM (
Cool Down
).
3. Press Throttle DOWN BUTTON again and
wait for speed to level off at 900 RPM (
Idle
).
4. Manual PTO: Disengage it now.
Automatic PTO, go to Step 4.
5. Turn key to OFF (O) position.
Clutch Handle
Fuel Tank
-
Open Side Door
(Layout May Vary)
WARNING:
Your HATZ Diesel Engine is an
EPA Tier 4 FINAL certified com-
puter controlled engine.
Do not attempt to re
-
program the
ECM by pressing buttons at ran-
dom on the control panel. Contact
Air Burners Customer Support De-
partment for help, if any errors
have occurred.
Call 772
-
220
-
7303
The engine does not require DEF.
Engine Compartment & Controls
(Layout May Vary)
RUNNING
Engine RPM
’
s (air
-
fan speed) is pre-
programmed and fixed at positions
Idle,
Cool Down, Operating Low and Oper-
ating High
.