Mounting

Front Case

Single-gang box

83.5mm,

3-5/16"

Screw (2) 

Wall

Lift and pull off

Chassis

Loosen

Push either side

Operation

Plate

83.5mm,

(3-5/16")

Single-gang box

LE-D Unit

Connector

2-gang box

Stainless

Cover

Screw (2)

Screw (2)

Main Unit

83.5mm,

(3-5/16")

For surface wall cable run, pass through 
opening on top or bottom of back case. 

LEM-1DL

LE-D

LE-DA

Back wiring

LE subs

Wiring

+

1

E

EL
EL

R

for AC or DC power supply 

for calling & communication
for communication (common)
for door release & its power supply
Normally open dry contact closure

+


1

E

EL, EL

}

AC Transformer

PT-1210N

NP

NP

NP

PT-1210N

LE-DA

DOOR RELEASE

EL-12S

(AC 12V, 125mA)

LEM-1DL

1

E

1

E

+

EL

EL

AC Transformer

PT-1210N

NP

NP

PT-1210N

LE-DA

DOOR RELEASE

(Max. AC 30V, 1A

Max. DC 30V, 1A)

LEM-1DL

1

E

1

E

+

EL

EL

Use a suitable power source

locally available.

When EL-12S door release is used;

When door release of OTHER manufacturer is used;   

The actual terminal locations are

different from the ones shown in

the diagram below.

NP: Non-polarized 

Run separately each cable to 

Door station and Door Release. 

Summary of Contents for LEM-1DL

Page 1: ...s plugged in It can cause electrical shock or damage to the unit 4 Do not install the unit in any of the following locations Fire electric shock or unit trouble could result Places under direct sunlight or near heating equipment boiler that varies in temperature Places subject to dust oil chemicals hydrogen sulfide hot spring Places subject to moisture and humidity extremes such as bathrooms cellar...

Page 2: ... INSTALLATION OPERATION MANUAL 1 call master with DOOR RELEASE button Master station Sub station Door release EL 12S AC 12V 125mA Power supply PT 1210N AC transformer North America only Or use an equivalent AC transformer AC 12V 10VA PS 1225UL PS 1225S PS 1225 PS 1215DIN LE D Surface mount door station LE DA Flush mount door station LE A 1 call sub station TALK OFF VOL VOICE TALK VOL VOICE LEM 1DL...

Page 3: ...alling communication for communication common for door release its power supply Normally open dry contact closure 1 E EL EL AC Transformer PT 1210N NP NP NP PT 1210N LE DA DOOR RELEASE EL 12S AC 12V 125mA LEM 1DL 1 E 1 E EL EL AC Transformer PT 1210N NP NP PT 1210N LE DA DOOR RELEASE Max AC 30V 1A Max DC 30V 1A LEM 1DL 1 E 1 E EL EL Use a suitable power source locally available When EL 12S door re...

Page 4: ...Aiphone will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses that may result AIPHONE CO LTD NAGOYA JAPAN Issue Date Apr 2016 83597 D P0416 AZ The object area of is the EU 5 Operations 1 Push call but...

Reviews: