System Components

Names & Features

FEATURES:

* Convenient door entry control system with DOOR RELEASE button

* AC transformer (PT-1210N) supplies power for both communication and door strike 

* Desk-top or wall-mountable master

 Call tone adjustment

   3-position volume switch, located under Operation Plate. 
  Adjusts call tone volume (Low - Medium - High).

 Package contents

• LEM-1DL
• Packet of screws
•  INSTALLATION & 

   OPERATION MANUAL

1-call master with 

DOOR RELEASE 

button

Master station

Sub station

Door release 

EL-12S

AC 12V, 125mA

Power supply

PT-1210N

AC transformer

(North America only)

Or use an equivalent 

AC transformer 

AC 12V, 10VA.

PS-1225UL

PS-1225S

PS-1225

PS-1215DIN

LE-D
Surface mount 

door station

LE-DA

  

Flush mount 

door station

LE-A
1-call sub 

station

TALK

OFF

VOL.

VOICE

TALK

VOL.

VOICE

LEM-1DL

TALK button

Operation Plate

Speaker / Microphone

OFF button

(standby)

Voice Volume Control

Door Release (      ) button

High

Low

CALL

CALL 

3-pos. 
call tone vol. switch
(under Operation Plate)

LEM-1DL

Summary of Contents for LEM-1DL

Page 1: ...s plugged in It can cause electrical shock or damage to the unit 4 Do not install the unit in any of the following locations Fire electric shock or unit trouble could result Places under direct sunlight or near heating equipment boiler that varies in temperature Places subject to dust oil chemicals hydrogen sulfide hot spring Places subject to moisture and humidity extremes such as bathrooms cellar...

Page 2: ... INSTALLATION OPERATION MANUAL 1 call master with DOOR RELEASE button Master station Sub station Door release EL 12S AC 12V 125mA Power supply PT 1210N AC transformer North America only Or use an equivalent AC transformer AC 12V 10VA PS 1225UL PS 1225S PS 1225 PS 1215DIN LE D Surface mount door station LE DA Flush mount door station LE A 1 call sub station TALK OFF VOL VOICE TALK VOL VOICE LEM 1DL...

Page 3: ...alling communication for communication common for door release its power supply Normally open dry contact closure 1 E EL EL AC Transformer PT 1210N NP NP NP PT 1210N LE DA DOOR RELEASE EL 12S AC 12V 125mA LEM 1DL 1 E 1 E EL EL AC Transformer PT 1210N NP NP PT 1210N LE DA DOOR RELEASE Max AC 30V 1A Max DC 30V 1A LEM 1DL 1 E 1 E EL EL Use a suitable power source locally available When EL 12S door re...

Page 4: ...Aiphone will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses that may result AIPHONE CO LTD NAGOYA JAPAN Issue Date Apr 2016 83597 D P0416 AZ The object area of is the EU 5 Operations 1 Push call but...

Reviews: