Aiphone JF-2SD Installation & Operation Manual Download Page 2

- 2 -

English

F

rançais

Neder

lands

PRECAUTIONS

PACKAGE CONTENTS

1

INSTALLATION

2

WARNING

(Negligence could result in death or serious injury.)

1. High voltage is present internally. Do not open the case. Electric shock could result.
2. Do not dismantle or alter the unit. Fire or electric shock could result.
3. Do not connect any non-specified power source to the +, - terminals, and do not 

install two power supplies in parallel to a single input. Fire or damage to the unit 
could result.

4. Keep the unit away from water or any other liquid. Fire or electric shock could result.
5. Do not put any metal or flammable material into the unit through the openings. Fire 

or electric shock could result.

6. Do not use power supply with a voltage other than specified. Fire or electric shock 

could result.

7. Do not connect any terminal on the unit to AC power lines. Fire or electric shock 

could result.

CAUTION

(Negligence could result in injury to people or damage to property.)

1. Do not install or make any wire terminations while power supply is plugged in. It 

can cause electrical shock or damage to the unit.

2. Before turning on power, make sure wires are not crossed or shorted. If not, fire or 

electric shock could result.

3. When mounting the unit on wall, install the unit in a convenient location, but not 

where it could be jarred or bumped. Injury could result.

4. For power supply, use Aiphone power supply model specified with system. If non-

specified product is used, fire or malfunction could result.

5. Do not install the unit in any of the following locations. Fire, electric shock, or unit 

trouble could result.

Places under direct sunlight, or near heating equipment that varies in temperature.

Places subject to dust, oil, chemicals, etc.

Places subject to moisture and humidity extremes, such as bathroom, cellar, 
greenhouse, etc.

Places where the temperature is quite low, such as inside a refrigerated area or in 
front of air-conditioner.

Places subject to steam or smoke (near heating or cooking surfaces).

Where noise generating devices such as dimmer switches or inverter electrical 
appliances are close by.

6. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could 

result.

GENERAL PRECAUTIONS

1. Keep the unit more than 1 m away from radio or TV set.
2. This unit is for indoor use only. Do not use outdoors.
3. In areas where broadcasting station antennas are close by, the intercom system may 

be affected by radio frequency interference.

4. Keep the intercom wires more than 30 cm (12") away from AC 100~240 V lines. 

Noise and malfunction could result.

5. The unit is for wall-mount use only. For desktop applications, use desk stand.
6. When wall-mounted, the unit may become dusty. Clean with a soft cloth.
7. The unit case may become a warm with use, but this is not a unit malfunction.
8. If a cellular phone is used close by, the unit may malfunction.
9. Talk within 50 cm (20") or less from the unit. If you stand too far away, it may be 

difficult for the other person to hear the communication.

10. If there are loud noises around the unit (such as music playing or children crying), 

the sound may break up and be difficult to hear.

11. During communication, if you speak before the other person has finished talking, 

your voice may not be heard. Communication will proceed smoothly if you wait 
until the other person has finished before speaking.

12. Due to the environmental sound around the unit, it may hinder smooth 

communication, but this is not a malfunction.

JF-2SD

Mounting screws x 2

Wood mounting screws x 2

Installation & Operation manual

Mounting locations

2-1

The JF-2SD has switches on the right side. 
Allow at least 5 cm (2") of open space on the right side of the JF-2SD to enable the switches to be operated.

General Prohibitions

Prohibition on Subjecting the Unit to Water

Prohibition to Dismantle the Unit

General Precautions

+ 5 cm

(2")

JF-2SD

JF-2SD  06.8.23  1:22 PM  ページ2

Summary of Contents for JF-2SD

Page 1: ...STALLATION OPERATION MANUAL MANUEL D INSTALLATION ET D UTILISATION INSTALLATIE EN BEDIENINGSHANDLEIDING SUB STATION WITHOUT MONITOR POSTE SECONDAIRE SANS MONITEUR AUDIO BIJPOST JF 2SD JF 2SD 830075 07...

Page 2: ...he temperature is quite low such as inside a refrigerated area or in front of air conditioner Places subject to steam or smoke near heating or cooking surfaces Where noise generating devices such as d...

Page 3: ...Wall mounting bracket Wood mounting screws x 2 Mounting to 1 gang box Mounting screws x 2 Wall mounting bracket 1 gang box 1 Press the RELEASE button in order to unlock or securely insert the wires 2...

Page 4: ...the monitor station on again Terminal setting 2nd unit Setting changes are only required when a 3rd unit is connected Put the switch in the ON position and terminate the furthest sub station If the te...

Page 5: ...once again and after the beep communication ends Press TALK button momentarily and after the beep communicate hands free Transmit LED red lights when you talk and goes off as you listen to caller or h...

Page 6: ...of the master monitor station JF 2MED The factory setting is 30 seconds TECHNICAL PRECAUTIONS 7 SPECIFICATIONS 8 Operating temperature 0 C to 40 C 32 F to 104 F Cleaning Clean the units with a soft c...

Page 7: ...mis un degr d humidit lev salle de bains cave serre etc Endroits o la temp rature est tr s basse par exemple dans une zone r frig r e ou en face d un appareil de climatisation Endroits expos s la vape...

Page 8: ...ol en PE poly thyl ne C ble 2 3 MONTAGE 3 C blage saillant Support mural Vis de montage bois x 2 Montage sur une bo te simple Vis de montage x 2 Support mural Bo te simple 1 Appuyez sur le bouton de d...

Page 9: ...qu une 3 me unit est branch e Placez le commutateur sur la position ON sur le poste secondaire le plus loign Si le param tre de la borne est incorrect le moniteur couleur mains libres et le poste seco...

Page 10: ...ermine apr s le bip Appuyez bri vement sur le bouton parole TALK et communiquez en mains libres apr s le bip La LED rouge s allume quand vous parlez et s teint quand vous coutez votre correspondant ou...

Page 11: ...Le son de notification ne s arr te que le temps d fini par les param tres d entr e du capteur externe du moniteur ma tre JF 2MED Le r glage par d faut est 30 secondes PRECAUTIONS TECHNIQUES 7 SPECIFIC...

Page 12: ...enz Op plaatsen waar de temperatuur erg laag is zoals in een koelruimte of voor de airconditioning Op plaatsen die blootstaan aan stoom of rook nabij verwarmingstoestellen of kookfornuizen Wanneer to...

Page 13: ...de massieve geleiders worden aanbevolen Kabel 2 3 MONTAGE 3 Bekabeling bovenop de muur Muurmontagesteun Houtmontageschroeven x 2 Montage met muur aansluitdoos Montageschroeven x 2 Muurmontagesteun Muu...

Page 14: ...alleen nodig als een volgend toestel wordt aangesloten Zet de schakelaar in de stand ON en sluit de lijn op de laatste bijpost af Als de schakelaarinstelling verkeerd is laten de monitorpost en de bij...

Page 15: ...ek knop TALK Na de pieptoon wordt de communicatie be indigd Druk kortstondig op de spreek knop TALK en spreek handenvrij na de pieptoon De zend led rood is aan terwijl u spreekt en gaat uit als u naar...

Page 16: ...d is in de ingangsinstellingen van de externe sensor van de monitor hoofdpost JF 2MED De fabrieksinstelling is 30 seconden TECHNISCHE VOORZORGSMAATREGELEN 7 TECHNISCHE GEGEVENS 8 Bedrijfstemperatuur 0...