Aiphone IXG Series Quick Start Programming Manual Download Page 7

From the top menu, select 

Connection

 and click Association Settings

. Here, stations created in the previous 

steps will be associated to stations found on the network. Select a station from the 

Station Settings List and 

one from the Station List

 below. Clicking  

Apply 

 will assign the Station Name and IP Address to the station, 

and that station will quickly reboot.

Association Settings

Scroll down to confirm the stations were successfully associated. If the wrong station information was 

associated to a station, select that station on this list and click  

Remove Association 

. Once removed, scroll 

up and associate the station correctly. 

Typically, stations deployed 

across a managed network 

cannot be found by Support 

Tool unless the network 

is configured to allow this 

broadcast search. In this case, 

it may be easier to move the 

stations to a switch local to the 

programming PC than it would 

be to configure the network 

to allow a network-wide 

broadcast.

If a Station Search fails immediately, go to 

File 

from the top menu and select 

IXG Support Tool Settings

. Find the Select 

NIC drop-down and select the correct NIC Support Tool should use, and click  

Okay

 . Return to Association Settings to 

try again. If the Station Search continues to fail immediately, a local antivirus or firewall may be preventing this action. 
Disabling one or both of these may be a simple solution in quickly finishing the initial system configuration.

Associated Station List

Summary of Contents for IXG Series

Page 1: ...4 1 2 1 3 4 IXG SERIES IP Multi Tenant Video Intercom This is an abbreviated programming manual addressing basic program settings for an IXG System using the IXG Support Tool A complete set of instru...

Page 2: ...uire advanced network configuration or routing to function properly in this environment It is possible for Windows Defender or other firewalls and antivirus software to block the broadcast the Support...

Page 3: ...mmunicate with Inside and Outside Area units Guard and Entry Units as well as other Commercial Units The two private Door Stations will only call to stations within their Unit Commercial Unit x8 If up...

Page 4: ...Management Company Information This information is a requirement for system or account recovery when using the IXG App Click Finish to continue Getting Started All ID and Passwords should be recorded...

Page 5: ...the Units will have then click Apply Units Stations From left to right select the Building Number the Unit will belong to set the Unit Number and click the Unit Type button to select a Unit type This...

Page 6: ...top of the screen to enter an IP address range to automatically assign all stations Edit the Admin ID and Password for each station as well as optionally create an ONVIF and RTSP ID and Password for...

Page 7: ...correctly Typically stations deployed across a managed network cannot be found by Support Tool unless the network is configured to allow this broadcast search In this case it may be easier to move th...

Page 8: ...enter an ID Password and Email Address Click Create to continue Once the Upload is complete select File from the top menu and click Export System Configuration Export this system s configuration to s...

Page 9: ...QR Code is generated for each specific Residential Unit For Residential Units the app registration QR code can be sent directly to the IXG 2C7 Tenant Station in the Unit Select App Integration from th...

Page 10: ...from the top menu and click Property Manager Settings Here tenants can be moved in and out Unit and Station names can be edited Mobile Apps can be added or removed from the system and other basic sys...

Page 11: ...cess Codes to allow residents or known visitors to enter the building by entering a code at the Entrance Station Up to 9 999 codes can be created At the top of the screen use the drop down options to...

Page 12: ...an record audio and video to a local microSD card when a call is placed or once communication is established with a station Enable these functions by expanding Function Settings and clicking Recording...

Page 13: ...usted for the door stations and not the master stations Enable SIF Functionality enter 0100 for the Program Type set the IPv4 address to the IP address that will later be assigned to the IXW MA enter...

Page 14: ...ect Relay Output Starting with Relay Output 1 select Contact Change SIF Event and then specify the Station Number of the station activating the Relay Output 1 Once these values are set click Update De...

Reviews: