5.

6.

2). Battery operating time

     Battery operating time depends on battery capacity and current, and the calculation 

formula of operating time is: battery capacity divided by current, that is, battery capacity 

divided  by  the  value  of  the  load  power  divided  by  battery  voltage  times  110%.  For 

example,  battery  specification  is  12V,  2000Ah,  load  power  is  1000W,  so  the  total 

discharge time is 2000Ah÷ (1000÷12×110%) ≈21.8 hours.

Notice:

 The result of the formula above is on the basis of discharging rate of 20 hours of 

the  battery,  that  is,  the  result  is  from  the  discharging  current  of  2000Ah  battery  not  to 

exceed 100A. When the charging current exceeds this value, the discharging period will 

be  reduced.  And  the  capacity  of  the  battery  may  also  influence  the  result.  See  the 

specification of the battery manufacturer for more detailed information.

6. Connection

1) Grounding

   The power inverter has a terminal on the rear panel marked " Grounding "or "    ". This is 

used  to  connect  the  chassis  of  the  power  inverter  to  ground.  The  ground  terminal  has 

already  been  connected  to  the  ground  wire  of  the  AC  output  receptacle  through  the 

inverter.

  The ground terminal must be connected to the ground wire, which will vary depending on 

where  the  power  inverter  is  installed.  In  a  vehicle,  connect  the  ground  terminal  to  the 

chassis  of  the  vehicle.  In  a  boat,  connect  it  to  the  boat's  grounding  system.  In  a  fixed 

location, connect the ground terminal to earth.

Warnings:

2

●  Make  sure  to  tighten  all  connections. The  ground  wire  must  be  14AWG  (2.08  mm )  or 

even larger.

●  Do  not  operate  the  power  inverter  without  connecting  to  ground.  Electric  shock  may 

result.

2) Connect to the lead acid battery or other type within dc input range

(1)  Please  check  all  the  safety  precautions  before  connecting,  and  then  check  whether 

the  battery  voltage  is  in  accordance  with  the  input  voltage  of  the  inverter.  Battery  and 

inverter voltages must match.

(2)  The  connecting  wire  must  bear  enough  current.  These  inverters  require  1  AWT 

2

(53.5mm ) or larger wire for its battery connections.

Notice:

(1)  In  practice,  thicker  wire  can  be  replaced  by  two  thin  parallel  wires  if  the  total  cross-

sectional area of the wire meets the requirements. This may however cause an increase 

in RF.

(2) In high current, the input DC wire may produce a voltage drop, therefore, the operating 

voltage should be subject to the value on the terminals. If the voltage drop is too large, you 

can increase the cross-sectional area or reduce the length of the lead. 

(3) Connect cathode wire of the battery to the cathode terminal (black) on the rear panel of 

the inverter and then connect the anode wire of the battery to the anode terminal (red) on 

the inverter, and tighten them.

Warnings:

(1)  Please  wear  eye  protection  and  work  clothes  when  working  around  the  battery  to 

protect your eyes and skin from acid and corrosive objects. 

(2) In case acid makes contact with your skin, clean it  using soap and water as soon as 

possible. If the acid splashes into your eyes accidentally, rinse with cold water and go 

to a hospital.

(3) Do not put any combustible materials in the location of installation for it will result in a 

fire hazard.

(4) Keep good ventilation. The battery may produce a little flammable gas when used, so 

keep away from the inverter and it is better to install them in a different space.

(5)  Tighten  all  DC  connections,  or  it  will  result  in  over-  reduction  of  the  voltage  or  over-

temperature of the inverter.

(6)  Reverse  connection  of  the  polarities  or  short  circuit  will  burn  the  fuse  or  result  in 

permanent damage of the internal elements of the inverter.

(7) Remove all rings and jewelry when working around your inverter.

(8) Although there is over-voltage protection, it may also cause damage to the inverter if 

the input voltage is too high.

7. Usage

. How to use the inverter

1) Check the output voltage and capacity of the battery to make sure it is in accord with the 

requirements of the product.

2) Connect the battery and the DC cable of the inverter to ensure that the polarities are not 

connected reversely and are tight.

3)  Power  on  inverter:  Press  the  power  switch  of  inverter  or  remote  for  over  0.5s  and 

release. If the indicator light on the inverter or on the remote control box is on, it means 

that the inverter started to work normally. This method can avoid turning on the unit by 

mistake due to accidental touch.

4)  Before  plugging  anything  into  your  inverter,  make  sure  the  appliance  you’re  trying  to 

power  is  shut  OFF,  then  plug  it  into  the AC  outlet  of  your  inverter  and  power  on  your 

appliance.

5) Once finished using the inverter, turn off your electrical appliance and the inverter. Also, 

if  you  do  not  plan  to  use  the  inverter  for  a  long  period  of  time,  disconnect  it  from  your 

battery bank.

Summary of Contents for PE200012230S

Page 1: ...WARNING Please read this manual in its entirety before using or connecting this inverter It includes important instructions and safety tips Model number PE200012230S ...

Page 2: ...of advanced micro processor 2 Cooling fan with intelligent temperature control 3 USB power supply SPECIFICATION EN Model Power supply Voltage Output voltage Output frequency Output wave form Continuous power output Peak power output Under voltage safeguard Over voltage safeguard USB outlet Fuse Operating temperature Dimension LxWxH Weight Cooling fan Remote PE200012230S 12VDC 230Vac 50Hz Pure sine...

Page 3: ...e product with four screws 3 Mounting the remote control box Optional equipment 1 3 16 5 2 16 1 2 16 5 1 16 1 the remote is designed to be mounted on a dash or other surface where a hole should be cut so that it sits flush This is not a requirement however just a recommendation 2 The remote cable should be plugged into inverter and the remote before mounted Note Optional remote is not needed for i...

Page 4: ...y produce a voltage drop therefore the operating voltage should be subject to the value on the terminals If the voltage drop is too large you can increase the cross sectional area or reduce the length of the lead 3 Connect cathode wire of the battery to the cathode terminal black on the rear panel of the inverter and then connect the anode wire of the battery to the anode terminal red on the inver...

Page 5: ...s inside the inverter do not work until the case temperature rises up to about 104 F or 40 C 7 Switch off inverter or remote to turn off At that time the indicator lights for both inverter and remote are off The inverter does not consume current from the battery when it is switched off How to use USB power supply This model supplies a USB output and provides stable voltage at 5V DC maximum current...

Page 6: ...irst then open the inverter Use the internal soft start circuit of the inverter to buffer the start 11 Troubleshooting tips AIMS Power Warranty Instructions This product is designed using the most modern digital technology and under very strict quality control and testing guide lines If however you feel this product is not performing as it should please contact us techsupport aimscorp net or 001 7...

Reviews: