background image

User Manual for UBX-T

Auto Shut-Off Battery Pulse Tools

10000 SE Pine St.      Portland, Oregon 97216      Phone: 1-800-852-1368

www.aimco-global.com

Summary of Contents for UBX-T Series

Page 1: ...User Manual for UBX T Auto Shut Off Battery Pulse Tools 10000 SE Pine St Portland Oregon 97216 Phone 1 800 852 1368 www aimco global com ...

Page 2: ...ents 1 Tool Safety 3 2 General Information 8 2 1 Importance of Operating Instructions 8 2 2 Proper Intended Use 8 2 3 Guarantee and Liability 8 3 Parts Diagram 11 4 Specifications 11 5 Tool Operation 12 5 1 Starting the Tool 12 5 2 Torque Adjustment for Individual Fasteners 13 5 3 Shut Off Information LED 14 5 4 Change Reverse Lever Direction 16 5 5 Factors that Can Affect Handling Torque 17 6 Bat...

Page 3: ...s tool for other purposes for safety and product longevity reasons Keep hands clear of all rotating assemblies to avoid injury Follow all instructions to prevent fire shock and personal injury Operators should be trained using this manual and have access to it When transferring this tool to new personnel ensure that this manual remains with it Working Environment 1 Keep work place tidy and clean w...

Page 4: ...i skid shoes for outdoor operation Cover long hair with a cap or hair cover Operation and maintenance of UBX T 1 Do not overload the tool Choose the right UBX model for your work You work better and more safely in the defined output range when using the proper tool 2 Do not use power tools with defective switches It is dangerous if the switch can neither turn the tool on nor off If a switch error ...

Page 5: ...oaded it can result in unintended start up and cause an accident 2 Only charge the batteries in chargers recommended by the manufacturer Recharging batteries in an unsuitable charger can cause fire explosion and liquid leaking 3 Only use the provided battery for power tools Modified battery packs such as those made by rebuilding from disassembled parts can cause fire injury breakdown or explosion ...

Page 6: ...isk the battery can become short circuited during the processing of general household garbage leading to fire or smoke Maintenance 1 Only allow your power tool to be repaired by a qualified technician using only original spare parts available from AIMCO This ensures that the safety of your device is maintained Do not disassemble repair or modify UBX charger or battery pack Doing so can cause fire ...

Page 7: ...es or in any explosive environment Power tools can generate sparks which can ignite the dust of vapors 3 To avoid risk of fire do not do the following actions Do not charge the battery on or near paper products like cardboard cloth products or vinyl Do not cover vent hole of charger while charging battery pack Do not tuck metal products or combustible materials into vent holes Do not charge batter...

Page 8: ...table for the type of tool Any other use beyond this is not considered proper intended use AIMCO is not liable for any damages resulting from non compliance 2 3 GUARANTEE AND LIABILITY NEW TOOL AND ACCESSORY WARRANTY Any new tool or accessory branded with the AIMCO Uryu AcraDyne or Eagle Industries name and purchased from AIMCO or through one of its authorized distributors or agents is warranted t...

Page 9: ...product may be amended by AIMCO from time to time in its sole discretion The liability of AIMCO hereunder shall be limited to replacing or repair ing at its option any products which are returned freight pre paid to AIMCO and which AIMCO determines to be defective as described above or at AIMCO s option refunding the purchase price of such products AIMCO reserves the right to make periodic changes...

Page 10: ...THE POSSIBILITY OF SUCH LOSS HOWEVER CAUSED WHETHER FOR BREACH OR REPUDIATION OF CONTRACT BREACH OF WARRANTY NEGLIGENCE OR OTHERWISE THIS EXCLUSION ALSO INCLUDES ANY LIABILITY WHICH MAY ARISE OUT OF THIRD PARTY CLAIMS AGAINST BUYER THE ESSENTIAL PURPOSE OF THIS PROVISION IS TO LIMIT THE POTENTIAL LIABILITY OF AIMCO ARISING OUT OF THIS AGREEMENT AND OR SALE Note The AIMCO Warranty confers specific ...

Page 11: ...ightening Motor Voltage Approx Free Speed Nominal Bolt Capacity Approx Torque Range Approx Weight Overall Length Sq Dr Model DC V rpm mm nm kg mm mm UBX T70 14 4 4 800 M8 M12 25 55 1 86 1 63 187 193 204 9 5 With 14 4V 4 2Ah battery With 14 4V 2 0Ah battery Allen Key for Torque Adjustment Shut Off Information LED Trigger Reverse Lever Battery Pack ...

Page 12: ...er off brakes to stop UBX Do not cover exhaust hole because doing so will turn up exhaust temperature to a dangerous level Exhaust Hole Keep squeezing until automatic stop Shut Off Information LED Model Battery Pack Fastening Condition Approx Number of Fasteners that can be Fastened during a Single Charge UBX T70 EYFB42 14 4V 4 2Ah UFT 16 M12 hard joint Fastening torque 40Nm for 0 4 sec per fasten...

Page 13: ...ick it in the relief valve s hole as the below arrow is pointing Adjust relief valve as per the following torque range Anvil Liner Assembly Relief Valve Adjusting Screw Torque Ranges Model Relief Valve Position Full relaxed to left full fastened to right UBX T70 25 Nm 55 Nm Testing Conditions Torque range was obtained by fastening UFT testers with a hard joint setting Torque observed by actual fas...

Page 14: ...ture stops the tool when the motor gets too hot regardless of relief valve shut off presets Refer to the following instructions regarding heat protection Heat Protection When the tool gets hot the LED lights red and the tool stops rotation Avoid use for at least 30 minutes Once the tool has cooled to room temperature and the LED is off it is safe to restart operation Work Interval Guideline Follow...

Page 15: ...The LED lights green with 1 pulse buzzer sounding for automatic shut off Retry until automatic shut off comes if incomplete job was detected 1 Set DIP switch to OFF opening screws and removing rear cover if it is not necessary to make buzzer sound 2 The LED lights orange instead of green for OK judgment due to retrial repairing the previous NOK result with LED lighting red about 3 sec DIP Switch L...

Page 16: ... Red Battery error Fully charge a brand new battery pack before first use Ending battery charging prematurely can cause the LED to incorrectly display remaining capacity If this happens charge the battery fully a few times and the LED should display correct information R L R Right L Left R L Pull in this direction Remove roll pin Reverse lever Battery Level Indicating LED Squeeze trigger and LED w...

Page 17: ... socket UBX and fastener Ensure that fit of the tool anvil to the driving socket and the socket engagement to the fastener are tightly toleranced Poor fit of the tool anvil to the socket and or poor fit of the socket to the fastener will result in inaccurate torque delivery to the tightened joint 3 Trigger Keep trigger fully squeezed until the tool automatically shuts off Early release of the trig...

Page 18: ...rox 0 35 kg Approx 0 58 kg 6 1 INSTALLING AND REMOVING THE BATTERY PACK Installing the Battery Align barbs of tool 3 on each side to barbs on battery and push battery toward UBX until it makes a click sound Removing the Battery Hold spring loaded jaw down and slide battery forward to unload Attach pack cover to battery s terminals to protect it from dust Align mark with first rib on the battery pa...

Page 19: ...pack Depending on work conditions the battery pack will perform approximately 500 charge discharge cycles It is time to replace the battery pack with a new one when the length of charge life decreases to half despite an initial full charge Battery pack storage Store lithium ion battery packs without charge after use Remove any foreign matter from terminals Cover battery using pack cover which help...

Page 20: ...he tool design Anvil stops rotating at slow speed Motor heat protection has been activated Release trigger Fully depress trigger and tool will not start even if the anvil is fixed again Torque delivered is lower than preset torque Bit or socket has worn out Replace bit and socket with a new one Number of fasteners per full charge has decreased Battery charge low or battery is at end of lifespan Re...

Page 21: ...ool every 100 000 cycles or every 3 months whichever comes earlier 8 MAINTENANCE Danger Warning A battery pulse tool is a precision tool Disassembly assembly and adjustment require exclusive JIGS plus testers and trained tech niques Incorrect disassembly re assembly or adjustment can cause not only insufficient power but also accidents Ask for these services from an authorized service center The m...

Page 22: ...7 UBX EXPLODED VIEW ...

Page 23: ...1 41 910 475 0 Switch Assembly 1 42 910 476 0 Nylon Mesh 1 43 910 477 0 Mesh Plate 1 44 911 046 0 Battery Board Assembly 1 Index Part Description Qty 45 911 042 0 Motor Assembly T type L 35 Parts 46 47 1 46 863 890 1 Motor T type 1 47 863 891 1 Control Board with LED and Buzzer 1 48 944 203 0 Supporting Ring 3 1 x 5 x 1 1 49 944 312 0 Backup Ring P12 Bias 1 50 945 026 0 Allen Head Bolt M4 x 16 4 5...

Page 24: ...HEADQUARTERS 10000 SE Pine Street Portland Oregon 97216 Phone 503 254 6600 Toll Free 1 800 852 1368 AIMCO CORPORATION DE MEXICO SA DE CV Ave Cristobal Colon 14529 Chihuahua Chihuahua 31125 Mexico Phone 01 614 380 1010 Fax 01 614 380 1019 WWW AIMCO GLOBAL COM ...

Reviews: