Page 2: ... Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electrical shock PERSONAL SAFETY Stay alert observe the task at hand and use common sense when using product Do not use when tired or under the influence of drugs alcohol or medication A moment of inattention can cause personal injury Use safety equipment Always wear eye protection Safety equip...

Page 3: ...s to securely mount your Auditor Torque Cube to the workstation prior to use The Auditor Torque Cube is setup with thru holes for 3 8 9 mm x 4 100 mm fastening bolts or screws During operational use the AuditorTorque Cube is subjected to rotational forces that require 2 points of attachment to the work station to secure against Dowel pins of at least 2 50 mm may also be used at the work station wh...

Page 4: ...or use with a serial printer or Windows PC device Dimensions 3 125 79 375 mm Wide 3 75 95 25 mm High 3 23 82 55 mm Deep 2 5 lb 1 13 kg Power Requirements 9 26V DC 150 mA min Supplied by 100 220VAC Input Transformer Battery Internal non field serviceable NiMh pack 32 F 0 C to 122 F 50 C Data Communications RS 232 Accuracy 1 of Indicated Reading within top 90 of Full Scale Range 10 to 100 of Full Sca...

Page 5: ...the same direction a simulated hard joint is achieved Fig B Alignment of the concave shapes in an opposing manner a simulated soft joint is achieved Fig C Differing combinations allow for simulated medium joints to be achieved Fig D Fig A Fig B Fig C Fig D Prior to use remove the Joint Simulator from its bag Loosen the Hex Screw and stack the Bellville Washers according to your joint condition nee...

Page 6: ...gh the available units Kgf M Kgf Cm gf Cm Ncm Nm FT LB IN LB IN OZ Pressing any other key will return to SAMPLE mode ENT Pressing ENT will send the current reading to the serial port and clears the screen MDE ENG Pressing MDE ENG buttons simultaneously displays the Program Menu See Program Menu section for details ACTIVE DISPLAY Active Display Mode is the normal operating mode used by the Auditor ...

Page 7: ...st shown setting will be held PPER PEAK BLANKING Minimum peak as a percentage of full scale Readings below the SET value will not be displayed Settings in the range of 2 50 are available Pressing ENT will sequentially increase the by one with each press At 50 the unit will scroll back to 2 with the next press of ENT After 5 seconds of no changes the unit will revert to Active Display Mode and the ...

Page 8: ...ers 1 20 Pressing ENT at the number 20 scrolls the menu selection back to OFF After 5 seconds of no changes the unit will revert to Active Display Mode and the last shown setting will be held The internal battery pack contained in the Auditor Torque Cube is non user serviceable When treated properly the battery pack should provide approximately 12 hours of continuous use from a full charge The bat...

Page 9: ... RS232 cable enabling connection to a seRial printer data collector computer or other RS 232 enabled device Values are sent via RS 232 each time the unit Auto Clears AC or the ENT or CLR buttons are pressed RS 232 Transfer Protocol Protocol Value Cable P N RS232C Mini Plug Auditor CUBE Dsub 9 Pin Baud Rate 9600 Parity None Bits 8 Stop Bit 1 Flow None RS 232 Data Stream Format Mmmbsdddddbuuuuucl wh...

Page 10: ...set level HIGH LIMIT Use the High Limit setting as a means of visually alerting the operator when a reading is above a desired maximum value The RED LED will illuminate to let the operator know that the achieved reading was above the preset level CAL For factory authorized service center use only NEW TOOL AND ACCESSORY WARRANTY Any new tool or accessory branded withtheAIMCO Uryu AcraDyne or Eagle ...

Page 11: ...es the right to make these changes without incurring any obligation or incorporating such changes or updates in tools or parts previously distributed THE AIMCO WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND AIMCO EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS WARRANTY SETS FORTH THE SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT STRIC...