20
Screen 17: Adjust Average Sample Fastening Time
Max. 9.99 seconds.
Press
to increase; Press
to decrease.
Press
to confirm and switch to the next
screen.
Step 15:
Screen (18) shows the accumulative number of incomplete
fastening tasks passed when there is defective set.
Screen 18: Number of Incomplete Fastening Tasks
Max. 60,000 sets
Press
to confirm and switch to the next
screen.
Step 16:
Screen (19) lets you save the values of the current Memo Set.
Screen 19: Save Set Values
Press
to save; Press
to cancel and
return to screen (6)
Step 17:
If you want to set the next item, press
on screen (6) to select
the item and repeat steps 7
–16.
Step 18:
Once you are finished, press
to return to screen (1). Press
to see count work screen (2).
Step 19:
Using WORK I/P function:
19-1: Connect to the production line
You can monitor your production line by connecting B5 & B6 of the JP-B
socket to the external controller. Once B5 & B6 are connected to the
workstation, the positioning sensor signal will be transported to the AM
Controller, and it will become a monitor. The alarm will sound if you pass
the incomplete fastened unit (the torque value, the fastening time, and
numbers of screws must reach the preset values). If the unit itself is
defective, you can pass it and press
to silence the alarm and return
Summary of Contents for AM-45