background image

Introduction

Safety Information

Thank you for your purchase of an AcraDyne® HT Series Pneumatic Nutrunner  These Nutrunners offer a reliable and 
dependable solution for the installation and removal of heavy-duty fasteners in a variety of industries that require high torque 
capability, accuracy, power and safety 

1)  WORK AREA

a   Keep work area clean and well lit  Cluttered and dark 

areas invite accidents 

b   Do not operate power tools in explosive atmospheres, 

such as the presence of flammable liquids, gases or 

dust  Power tools create sparks which may ignite  
the dust or fumes  Ensure there are no cables or gas 
pipes that may cause a hazard if damaged by the tool 

c   Keep children and bystanders away while operating a 

power tool  Distractions can cause you to lose control 

d   Be aware of trip hazards such as air lines and 

electrical cords in the work area 

3)  PERSONAL SAFETY

a  

Only qualified and trained operators should install and 

adjust tool 

b   Stay alert, watch what you are doing and use common 

sense when operating a power tool  Do not use a 

power tool while you are tired or under the influence 

of drugs, alcohol or medication  A moment of 
inattention while operating power tools may result in 
serious personal injury 

c   Use safety equipment  Always wear eye protection  

Safety equipment such as dust mask, non-skid 
safety shoes, hard hat, or hearing protection used for 
appropriate conditions will reduce personal injuries   
If the maximum duty cycle of the attached tool is 
exceeded or the tool temperature exceeds 50° C , 
then the operator should wear protective hand wear 
(gloves) 

d   Avoid accidental starting  Ensure the switch is in the 

off-position before plugging in  Carrying power tools 

with your finger on the switch or plugging in power 

tools that have the switch on invites accidents 

e   Remove any adjusting key or wrench before turning 

the power tool on  A wrench or a key left attached to a 
rotating part of the power tool may result in personal 
injury 

f   Do not overreach  Keep proper footing and balance 

at all times  This enables better control of the power 
tool in unexpected situations  

g   Dress properly  Do not wear loose clothing or jewelry  

Keep your hair, clothing and gloves away from moving 
parts  Loose clothes, jewelry or long hair can be 
caught in moving parts 

h   If devices are provided for the connection of dust 

extraction and collection facilities, ensure these are 
connected and properly used  Use of these devices 
can reduce dust-related hazards 

i  

Ensure hose and fittings are securely fastened to 

prevent injury from disconnected whipping hose  
Whenever universal twist coupllings are used, lock 
pins should be installed and whip check safety cable 
shall be used 

j   Always shut-off air supply, drain air hose pressure 

and disconnect tool from air supply when not in use, 
before making changes to accessories or when in 
repair  Air under pressure can cause severe injury 

k  

Do not modify tool. Any modification of tool could 

result in personal injury 

l   Failure of the workpiece, tool or accessories can 

generate high velocity projectiles 

4)  POWER TOOL USE AND CARE

a   Do not force the power tool  Use the correct power 

tool for your application  The correct power tool will 
do the job better and safer at the rate for which it was 
designed  Hold tool with a light, safe grip 

b   Do not use the power tool if the switch does not turn 

it on and off  Any power tool that cannot be controlled 
with the switch is dangerous and must be repaired 

c   Tool is intended for the use on threaded fasteners with 

impact grade sockets  All sockets and extensions should 
be secured with pins and o-ring to the tool  Any other 
use of this tool is strictly forbidden 

d   Inspect tool to ensure all markings are visible and legible 
e   Operator and maintenance personnel should physically 

be able to handle the bulk, weight, and power of the tool  
If not, the use of a balancer is recommended 

f    Should the operator experience discomfort or pain in 

the hands, arm or shoulders, do not ignore it and seek 

the advice of a qualified medical professional.

CAUTION – Do not use the Acradyne® HT nutrunning system without fully reading this manual and having a complete 

understanding of the correct usage of a high torque-delivering tool and any associated reaction bars/accessories.

SAVE THESE INSTRUCTIONS

Summary of Contents for AAP1B66400A

Page 1: ...10000 SE Pine St Portland OR 97216 800 852 1368 Fax 800 582 9015 www aimco global com High Torque Pneumatic Nutrunners Operation Manual ...

Page 2: ...nvironmental 4 Air Supply 4 Physical 4 Sound and Vibration Emissions 4 Lubrication 4 Operation 5 Torque Adjustment 5 Installing Reaction Bar 6 Reaction Bar Safety 7 Reaction Bar Guidelines 7 Sockets 7 Pinch Point 7 HT Pneumatic Tool Accessories 8 AIMCO Warranty 10 ...

Page 3: ...better control of the power tool in unexpected situations g Dress properly Do not wear loose clothing or jewelry Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts h If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used Use of these devices can redu...

Page 4: ... 5 A 8 9 AR 9 7 A 13 3 AR 15 8 A 338 AR 400 1 5 R Reversible AAP1B66600A AAP1B772000A AAP1B772950A AAP1B885100A AAP2B771400A AAP2B772000A AAP2B773000AR Physical Sound and Vibration Emissions Sound Pressure Level 82 dB A Sound Pressure Level 93 dB A Sound Level uncertainty 3 dB A Vibration Value 2 5m s2 Vibration Level Uncertainty 0 7 m s2 Sound and vibration emissions for the AAP1B Series tested p...

Page 5: ...peed Pneumatic Series Square Drive Reverse Lever Trigger Button Air Inlet Directional Exhaust Square Drive Reverse Lever Trigger Button Air Inlet Exhaust Operation Torque Adjustment Each AcraDyne HT Air tool is delivered with a Pressure versus Torque Output Calibration Graph See example Calibration Graph See example Using a reliable regulator with gauge in the air supply line adjust the supply air...

Page 6: ... AN OBJECT OR RESTRICTION DURING OPERATION OF THE TOOL TO AVOID CREATION OF A PINCH POINT AN OEM SOURCED OR APPROVED REACTION BAR OR PROPER REACTION ABSORPTION DEVICE MUST BE IN USE AND IN GOOD CONDITION ANY TIME THE TOOL IS OPERATED PROPER TORQUE REACTION MANAGEMENT PRACTICES MUST BE OBSERVED AT ALL TIMES FAILURE TO UNDERSTAND AND EMPLOY SAFE OPERATING TECHNIQUES CAN RESULT IN TOOL DAMAGE APPLICA...

Page 7: ...S PERSONAL INJURY LOSS OF LIMB OR DEATH The guidelines offered below are only guidelines Should there be any doubt as to the integrity of a proposed reaction strategy it is strongly advised to consult with an AcraDyne authorized representative prior to executing strategy Reaction force is equal to the point being applied The magnitude of the reaction force is dependent upon the perpendicular dista...

Page 8: ...HT Pneumatic Tool Accessories ...

Page 9: ...HT Pneumatic Tool Accessories ...

Page 10: ...ability of AIMCO hereunder shall be limited to replacing or repairing at its option any products which are returned freight prepaid to AIMCO and which AIMCO determines to be defective as described above or at AIMCO s option refunding the pur chase price of such products AIMCO reserves the right to make periodic changes in construction or tool design at any time AIMCO specifically reserves the righ...

Page 11: ...Notes ...

Page 12: ...E MEXICO SA DE CV 10000 SE PINE STREET AVE CRISTOBAL COLON 14529 PORTLAND OREGON 97216 CHIHUAHUA CHIHUAHUA 31125 PHONE 503 254 6600 MEXICO TOLL FREE 1 800 852 1368 PHONE 01 614 380 1010 FAX 01 614 380 1019 LIT MAN168 REV 01 24 22 PRINTED IN USA 2022 ...

Reviews: