P U S H B U T T O N S A N D D I S P L A Y
1 5
Some display messages are presented in the following tables:
Table 1. Display messages
Message
E700 ID
EDIS ID
Meaning
UNIT ID
0.0.0
Unit ID
SER No
C.1.0
Serial number
C DATE
0.9.2
Current date
C CLO
0.9.1
Current time
CONF ID
0.2.0
Configuration ID
P DATE
C.2.1
Configuration date
IN STAT
C.51
Input status
OUT STA
C.52
Output status
RE STAT
C.59
Register status
ABC TARIFF
C.53 TARIFF
Tariff register menu
ABC LP
C.54 LP
Load profile menu
ABC BP
C.55 Bp
Billing Period counter menu
ABC U-I-P
C.56 U-I-P
Instantaneous values menu
ABC OTHER
C.57 OTHER
Miscellaneous menu
ERR 001
F.1
Error register 1: application
ERR 002
F.2
Error register 2: core
ERR 003
F.3
Error register 3: alarms
---END ---END END
tag
Table 2. Display messages - instantaneous values
Instantaneous values
Message Meaning
E700 ID
EDIS ID
A1
21.24
Active power L1
A2
41.24
Active power L2
A3
61.24
Active power L3
A
1.24
Active power sum
R1
23.24
Reactive power L1
R2
43.24
Reactive power L2
R3
63.24
Reactive power L3
R
3.24
Reactive power sum
S1
29.24
Apparent power L1
S2
49.24
Apparent power L2
S3
69.24
Apparent power L3
S
9.24
Apparent power sum
U1
32.24
Line voltage L1
U2
52.24
Line voltage L2
U3
72.24
Line voltage L3
I1
31.24
Line current L1
I2
51.24
Line current L2
I3
71.24
Line current L3
PF1
33.24
Power factor L1
PF2
53.24
Power factor L2
PF3
73.24
Power factor L3
©
Enermet Oy
E700
Manual for Installation and Use v. 6.31
ACTIVE INFORMATION MANAGEMENT