3.1.8.3  Network Emulation Coupling 

Network Emulation Coupling

 is a special option for the  ANET1553.  

The  AIM  design  includes  on-board  Bus  Network  circuitry  that  is  software  selectable.  
This  allows  the  user  to  connect  directly  to  a  single  terminal  device  without  the  need  for 
any  bus  coupling.    The  Network  Coupling  mode,  selected  by  the  user  via  software 
controls,  provides  a  terminated  MILbus  network  simulation  on  the  ANET1553  to  allow  a 
direct connection  between  the  ANET1553 and the  external  terminal. 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

3.1.8.4  Isolated Coupling 

In

  Isolated  Coupling

  mode  the  ANET1553  MIL-STD-153  frontend  is  physically 

suspended  from the  ANET1553  TWINAX  frontend  connectors  via relais. 
 
 

 

ANET1553 

(with  on board 

Bus Network) 

RemoteTerminal 

(Transformer 

Coupled) 

  A            B 

Figure 3-21  Network Emulation Coupling

 

Summary of Contents for ANET1553-1

Page 1: ...ANET1553 Single Dual Stream MIL STD 1553 Ethernet Interface AIM GmbH Sasbacher Str 2 79111 Freiburg Germany Tel 49 761 45229 0 Fax 49 761 45229 33 sales aim online com www aim online com April 2014 V...

Page 2: ......

Page 3: ...i ANET1553 Users Manual for Single Dual Stream MIL STD 1553 Ethernet Interface V01 03 Rev C April 2014 AIM No 60 11E2x 86 V01 03 C...

Page 4: ...PA 19053 267 982 2600 877 520 1553 salesusa aim online com AIM UK Cressex Business Park Lincoln Rd High Wycombe Bucks HP12 3RB England 44 1494 44 68 44 salesuk aim online com Notice The information th...

Page 5: ...2013 F Scherer Getting Started Section added V01 01 Rev A 21 05 2013 F Scherer Complete revised V01 02 Rev A 07 06 2013 F Scherer Some extensions V01 03 Rev A 04 04 2014 M Melcher Added Wireless Devi...

Page 6: ...Tool 13 3 1 4 Configuring the ANET1553 14 3 1 4 1 Setting the IP Address and Board Alias Name 15 3 1 4 2 Configuring Wireless Network Interfaces 15 3 1 4 3 Configure System Services 19 3 1 4 4 Config...

Page 7: ...der Decoder 35 4 7 2 Time Tag Methods 36 4 8 Powering the ANET1553 36 5 Compiling and running a Sample Project 37 6 Single or Simulator Only Functions 41 6 1 Simulator Only Versions 41 6 2 Single Func...

Page 8: ...Configuration Tool Update finished 22 Figure 3 12 ANET Web Configuration Tool Update Log File 22 Figure 3 13 Emergency Boot Button 23 Figure 3 14 Connect to ANET1553 with PBA pro 24 Figure 3 15 Conne...

Page 9: ...ndalone module connected with an Ethernet link to a host computer An external power supply wall adapter is used to power the ANET module Different coupling modes such as Transformer Coupling Network E...

Page 10: ...the documents referenced and the contents of this document the contents of this document shall have precedence 1 2 1 Industry Documents 1 MIL STD 1553B Department of Defense Interface Standard for Dig...

Page 11: ...twork Detection Tool These files are automatically copied to the system e g HOST PC by installing the BSP software package The software is available on DVD from AIM or via a download from AIM Online i...

Page 12: ...he BSP installation will result in the creation of the following Program Folder icons which can be found by going to Start All Programs AIM GmbH ANET1553 BSP Vxxxx The BSP installation will also resul...

Page 13: ...e g the AIM Network Detection Tool API Application Programming Interface DLL Files and Libraries required to develop an application for Windows systems Board Update A compressed on board software fir...

Page 14: ...onnectors Front panel Up to four TWINAX connectors at the front side providing the MIL STD 1553 channels Back panel Auxiliary 15 pin High Density DSUB connector for the Trigger IN OUT signals IRIG IN...

Page 15: ...ectors For connecting to the external MILBus up to four TWINAX connectors respectively two TWINAX connectors for a single channel ANET1553 1 Module are provided at the front panel The figure at the ri...

Page 16: ...2 IRIG Out 7 Discrete I O 2 12 Discrete I O 5 3 Trigger OUT CH1 8 Trigger OUT CH2 13 Discrete I O 6 4 Trigger IN CH1 9 Trigger IN CH2 14 Discrete I O 7 5 GND 10 Discrete I O 3 15 Discrete I O 8 Table...

Page 17: ...F Normal operation 1 LED RED illuminated Illuminated during power on cycle 2 LED BLUE fast pulsing Fast pulsing blue during ASP LINUX boot up 3 LED BLUE slow pulsing Slow pulsing blue when the on boar...

Page 18: ...ower down the ANET1553 press the button again If the button is pressed for approximately 3sec a power down is forced without shutdown cycle of the OS This is not recommended and should only be done in...

Page 19: ...twisted pair cable with RJ45 plugs can be used The DHCP server will automatically assign an IP Address for each ANET1553 in a network 3 1 2 2 The Network doesn t provide a DHCP sever Either the ANET1...

Page 20: ...onf charter in order to find any ANET1553 modules in your network The AIM Network Detection Tool makes use of Apple Bonjour a freeware Zeroconf implementation How to install and use Apple Bonjour and...

Page 21: ...Software DVD to start the AIM Network Detection Tool After some seconds it will show all ANET1553 modules visible in your network A double click on any ANET1553 module in the list will open the defau...

Page 22: ...ddress bar to connect to and to configure the ANET1553 First of all you have to enter a user name and password on the login screen the default login is User Name user Password aim After a successful l...

Page 23: ...network From the time when the Wi Fi USB device is attached to the USB port of the ANET1553 the Network Settings tab will show an additional section that allows configuring the Wi Fi device See figure...

Page 24: ...unauthorized access Use Unsecure if the network you want to join does not use any security mechanism Choose WEP if the wireless network is protected with Wired Equivalent Privacy WEP Last supported se...

Page 25: ...t The ANET1553 device can join this network So it is possible to control the ANET1553 device with the Windows based host device over the wireless connection The setup of the wireless access point need...

Page 26: ...d NETWORK_NAME key YOUR_PASSW The hosted network will use WPA2 encryption per default See the displayed settings after the call of a show hostednetwork command see below at para 6 5 start the hosted n...

Page 27: ...able to connect to the ANET1553 Figure 3 7 ANET Web Configuration Tool Services 3 1 4 4 Configure the password and set the System Log File formats Click on the Maintenance tab in the navigation bar s...

Page 28: ...intenance Tab to press the OK button on Reset all settings now After resetting the settings the password will be set to the factory default aim the Network Settings will be set to DHCP mode and the se...

Page 29: ...update is running Figure 3 10 ANET Web Configuration Tool Update is running If the update has been finished successfully the status should look like shown below Press Finish Update button to finish t...

Page 30: ...22 ANET1553 Users Manual Figure 3 11 ANET Web Configuration Tool Update finished Figure 3 12 ANET Web Configuration Tool Update Log File...

Page 31: ...ode boot is indicated by a red blinking LED When booting into the emergency mode the device will start up with its default factory settings e g user name password and IP address You are able to connec...

Page 32: ...ANET1553 with PBA pro After a re start PBA pro should show the available ANET1553 MIL Resources The figure below shows how it looks like for an ANET1553 2 For an ANET1553 1 only the MIL Resource is sh...

Page 33: ...lling operating system routines to open the AIM board and initialize a shared memory area for host to target communication For further informations see the AIM Software Reference Manual 3 1 8 Connecti...

Page 34: ...ot in length Since a Direct Coupled stub provides only limited isolation in the event of a device subsystem or terminal short Transformer Coupling is normally the recommended method of connecting to t...

Page 35: ...Coupling The electrical isolation prevents a terminal fault or stub impedance mismatch from affecting bus performance Figure 3 18 Stub Coupler Connecting to the bus using Transformer Coupling require...

Page 36: ...bus coupling The Network Coupling mode selected by the user via software controls provides a terminated MILbus network simulation on the ANET1553 to allow a direct connection between the ANET1553 and...

Page 37: ...one MIL STD 1553 channel The ANET1553 comprises the following main sections System FPGA Global RAM BIU Section Physical I O Interface with up to two Dual redundant MIL STD 1553B channels with programm...

Page 38: ...the MIL STD 1553 Encoder Decoder logic to handle up to two MIL STD 1553 channels the Trigger Logic to handle the Trigger I O signals in BC RT and BM operating modes and a SPI Flash for BIU Processor B...

Page 39: ...d RT FPGA internal trigger logic simultaneously and is caught by the operating mode BC RT BM where the trigger mode is activated The external Trigger IN pulse length must be at least 75 nanoseconds 4...

Page 40: ...uilt in USB interface has been made available to the user for mounting external mass data storage devices or e g a WLAN stick for wireless 4 6 Discrete I Os The ANET1553 module provides eight user pro...

Page 41: ...efore connecting an external voltage otherwise the output driver transistor can be damaged caused by a high short circuit current to GND Figure 4 4 Discrete I O circuitry Ground Discrete I O Pin conne...

Page 42: ...34 ANET1553 Users Manual Figure 4 5 Discrete I O Pin off board user series resistor Discrete I O Pin ANET1553 User external user voltage FPGA Output Pin Customized Discrete Output Rserial...

Page 43: ...ion On the ANET1553 a freewheeling IRIG function is implemented If no external IRIG signal is detected the Time Code Processor TCP switches automatically to the freewheeling operation mode If an exter...

Page 44: ...IG B source Connect external IRIG B source to IRIG IN and GND of all modules d Multiple AIM Modules with no external IRIG B source internally synchronized Connect the IRIG OUT signal and the GND of th...

Page 45: ...sample directory Start All Programs AIM GmbH PCI 1553 Windows BSP Vxxxx 1553_sample_project The 1553_sample_project program opens a board and provides a selection of sample functions to execute For fu...

Page 46: ...xxx Sample and open the solution 1553_sample_project sln Figure 5 1 File Structure Sample project To add the proper search paths for the include files 1 Right click the project and select Properties 2...

Page 47: ...n select OK Figure 5 3 Sample project preprocessor definitions To add the proper library 1 Right click the project and select Properties 2 Select the Linker Input 3 Under Additional dependencies if no...

Page 48: ...mple project library path To Build and Execute a Sample Program 1 Build Rebuild Solution 2 The executable will be stored in the Debug or Release subdirectory 3 Copy the api_mil dll into the Release an...

Page 49: ...T Simulator with Mailbox Monitor functionality but doesn t include the Chronological Monitor function 6 2 Single Function Version The Single Function functionality is intended for applications where a...

Page 50: ...42 ANET1553 Users Manual THIS PAGE INTENTIONALLY LEFT BLANK...

Page 51: ...he emergency system accepts the default user user and password aim Go to the Maintenance tab and press the Reset To Factory Defaults button This will reset the user name and password of the device The...

Page 52: ...44 ANET1553 Users Manual THIS PAGE INTENTIONALLY LEFT BLANK...

Page 53: ...bus switching logic not redundant Response time support via eight bit timer with 250ns resolution Error Injection Parity error on selected word SYNC pattern definable on half bit basis on selectable w...

Page 54: ...ccuracy after 10 Minutes 1ppm assuming input signal accuracy better than 50ppm Encoder Format IRIG B 122 Absolute Accuracy 25ppm standard Oscillator Signal Waveform Amplitude modulated sine wave Outpu...

Page 55: ...th 500ns IRIG IN AC coupled input resistor 10K with EMC protection 0 5 to 5 0 Vpp input voltage IRIG OUT AC coupled output resistor 51 with EMC protection 4 9VPP output voltage Discrete IO User defina...

Page 56: ...tional 1 channel 100 Bus Load PIN 4 5W Operational 2 channels 100 Bus Load PIN 6 1W Note All measurements are done with a VIN 12V Temperature Standard Temperature Range 0 C 50 C Extended Temperature R...

Page 57: ...code Format Type B I O Input Output IP Internet Protocol JTAG Joint Test Action Group IEEE 1149 1 Boundary Scan LCA Logic Cell Array XILINX Programmable Gate Array LED Light emitting Diode LVTTL Low...

Reviews: