START AND OPERATION (continuO)
12, RIGHT TURN (Forward stopped) - With the "right" lever in the stop position, push the -left" lever forward.
13. LEFT TURN (Spin stopped) - Pull the "left" lever to reverse and push the "right" lever forward.
14. RIGHT TURN (Spin stopped) - Pull the "right" lever to reverse and push the ''left" lever forward.
15. BOOM ELEVATION/LOWERING CONTROL LEVER - To raise the boom push the "Elevation Control Lever"
to the "up" position. When the desired height is reached return the lever to the stop position.
To lower the boom pull the "Elevation Control Lever" to the "down" position. When the desired position is
reached return the lever to the stop position.
16. BOOM ROTATION
CONTROL LEVER -
To rotate the boom select "right" or "left.' direction. Return the lever
to stop when the desired position is reached.
L\
DANGER
Before rotating the boom check for people and obstructions in the work area.
17. BOOM EXTENSION/RETRACTION LEVER - To extend the boom, move the lever to "out" position until the
desired position is reached. Return the lever to the stop position.
To retract the boom move the lever to the "in" position until the desired position is reached. Return the lever
to the stop position.
18 PLATFORM ROTATION - To rotate the platform select "left" or "right" with the rotation lever and hold until the
desired position is reached. Return the lever to stop position.
1_\. DANGER
When
driving in forward or reverse always place the platform in the forward direction as designated by
the direction arrow on the base of the work platform.
19. EMERGENCY STOP - When pressed, this push-button switch disconnects power to the upper and lower
controls and stops the engine. To restore power pull the emergency stop button out, so it is in the operating
mode.
20. EMERGENCY PUMP OPERATION - ln the event of a main pump or engine failure this control is used to
bring the boom down. The emergency pump runs only when the switch is held in the "on" position. Select
the desired function and place the Emergency Pump Swich" in the on position. Hold the switch on for thirty
(30) seconds, then off for thirty (30) seconds until the work platform is fully lowered.
▪
DANGER
Continuous operation of the "Emergency Pump Unit" could cause damage to the D.C. motor.
21. HORN ALARM OPTION - Press Horn Button to sound horn.
Always turn off light after use.
. L
CAUTION
Sound horn before operation to warn personnel in the work area.
22.
WORK LIGHT OPERATION -
Moving this switch to the "on" postion turnS on the work light.
1 9