LOWER CONTROL PANEL
1.
HOUR METER -
Activated when the engine is started, measures engine run time.
2.
REMOTE CONTROL SOCKET FOR TRAVEL FROM BASE (OPTION) -
This option is used to move the
work platform from the ground position.
3.
BASE/PLATFORM CONTROL SELECTOR SWITCH -
This switch is used to switch power from the base
control to platform controls. When this switch is placed in the "on position",
it
shuts off platform controls and
activates the base control panel.
4. BOOM
ELEVATION SWITCH -
This switch controls the up down movement of the boom section. When this
switch is placed in the "boom up position" the boom raises. When this switch is placed in the "boom down
position" the boom lowers.
5.
EMERGENCY PUMP SW ITCH - This switch operates the emergency pump motor assembly. ln the event of
a pump or engine failure this control is used to bring the boom down. The emergency pump runs only when
the switch is held in the "on" position. Select the desired function, and place the "emergency pump switch" in
the "on" position. Hold the switch on for thirty seconds, then off for thirty seconds until the work platform is
fully lowered.
DANGER
CONTINUOUS OPERATION OF THE EMERGENCY PUMP UNIT COULD CAUSE DAMAGE TO THE D.C.
MOTOR.
6.
BOOM EXTENSION
SWITCH - This switch
is used to "extend" and "retract" the boom. To extend the boom,
select and hold the boom "extend" switch in the "extend" position until the desired position is reached.
Release the switch to stop. To retract the boom select and hold the boom "retract" switch in the "retract"
position until the desired position is reached. Release the switch to stop.
HIGH THROTTLE SWITCH -Use the accelerator switch to increase engine R.P.M. by selecting "high". Select
"low" to decrease engine R.P.M.
BOOM ROTATION SWITCH - This switch is used to rotate the boom clockwise or counter clockwise. To
"rotate" the boom select "left" or "right" with the "boom rotate switch" hold until the desired position is reached.
TO stop release switch.
9 . EMERGENCY STOP BUTTON SWITCH - This switch disconnects power when pushed. When pressed this
push button switch disconnects power to the upper and lower controls and stops the engine. To restore
power pull the "emergency stop button" out, step on the "foot switch, and the "power lamp" will glow.
10.. CHARGE INDICATOR LAMP - This lamp will
shut
off when the engine is running. If this lamp
is
glowing
when the engine is running, shut the engine down and check for the problem.
11. WATER TEMPERATURE LAMP - This lamp will shut off when the engine is running. If this lamp is glowing
when the engine is running, shut the engine down and check for the problem.
12,
ENGINE OIL PRESSURE LAMP - This lamp will shut off when the engine is running. If this lamp is glowing
when the engine is running, shut the engine down and check for the problem.