Mode No.6 Set the interval of updating the instantaneous flow rate display
If the L/min switch is pressed when Mode No. 5 is lit, the screen will switch to Mode No. 6 and display the following.
("
" shows the present setting value.)
1.
When the L/min switch is pressed for 2 seconds, the setting value will blink, showing ready for setting.
2. Each time the L/min switch is pressed, the setting value will change in turn. (Setting value is 0.5, 1.0, 2.0, 3.0, 4.0,
or 5.0 sec.)
(Default is 2.0 sec)
3. When the L/min switch is pressed for 2 seconds, the set value will be lit and setting will be completed.
Mode No.7 Set the pulse output digit
If the L/min switch is pressed when Mode No. 6 is lit, the screen will switch to Mode No. 7 and display the following.
("
" shows the present setting value.)
1.
When the L/min switch is pressed for 2 seconds, the setting value will blink, showing ready for setting.
2.
Each time the L/min switch is pressed, the setting value will change in turn. (Setting value is 0, 1, 2, 3, 4, 5, 6, 7,
or 8.)
"0" represents non-unit pulse. For setting values other than 0, each time the integrated flow rate display of the
setting value (i.e. digit) is counted upward, a pulse is outputted. (e.g., when set to 3, each time the third digit of
the integrated flow rate display is counted upward, a pulse is outputted.)
3.
When the L/min switch is pressed for 2 seconds, the set value will be lit and setting will be completed.
Note:
Set the pulse output digit greater than the most significant digit of pulse constant.
(If set to a value lower than the most significant digit of pulse constant, pulse output will be indefinite.)
When the L/min switch is pressed in this state, the screen will return to Mode No.1.
6.
Output digit selection
Mode No.6
Mode No.7
Set the equivalent value.
- Display the present set value in the light-on state.
Set the EXP value.
- Display the present set value in the light-on state.
Set the decimal point position of integrated flow rate display and the display unit.
- Display the present set value in the light-on state.
Set the decimal point position of integrated flow rate (trip) display and the display unit.
- Display the present set value in the light-on state.
Set the decimal point position of instantaneous flow rate display and the display unit.
- Display the present set value in the light-on state.
Set up the upgrade interval of the instantaneous flow rate display
- Display the present set value in the light-on state.
Set the digit of pulse output.
- Display the present set value in the light-on state.
(Blink)
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
Approx. 2 sec
(Blink)
(Blink)
(Blink)
(Blink)
(Blink)
(Blink)
1
.
1
.
2
.
3
.
4
.
5
.
6
.
2
.
3
.
4
.
5
.
6
.
7
.
7
.
7.