AIC SILOX S Installation And Maintenance Manual Download Page 2

2

I10_092-01 • SILOX S_EN

The quality of our products is essential to us, 

and we aim therefore at improving them contin-

ually. To this end, we reserve the right to change 

the technical characteristics and features of our 

products without prior notice. Please check for 

the latest revision of the manual on our website 

(www.myaic.eu).
The manufacturer shall not be held liable for any 

malfunction of the product resulting from:

 

î

The failure to comply with the safety and 

installation instructions provided herein,

 

î

The failure to comply with the safety and 

operation instructions and recommenda-

tions provided herein,

 

î

The failure to have the appliance main-

tained regularly,

 

î

A modification of the appliance that is not 

approved by the manufacturer,

 

î

The use the product for any other purpose 

than its intended use,

 

î

The use of components and accessories 

that are not approved by the manufacturer.

 

Installer’s Responsibility

The installer is responsible for the correct instal-

lation and commissioning of the appliance ac-

cording to:

 

î

The instructions and recommendations 

provided herein,

 

î

The applicable regulations and standards.

The installer shall provide the end-user with:

 

î

Any relevant explanation about the operation 

of the appliance and the hydraulic system as 

well as the safety devices that are provided,

 

î

Any instruction regarding periodic checks 

to be performed and possible anomaly to 

be reported,

 

î

All the documentation delivered with the 

appliance and installed accessories.

The installer shall also inform the end-user of the 

necessity to have the appliance checked and 

maintained regularly by a qualified professional.

End-user’s Responsibility

To ensure the best performances and safety of 

the appliance, the end-user shall:

 

î

Make sure that the appliance is installed, and 

commissioned by a qualified professional,

 

î

Make sure that the appliance is checked 

and  maintained  regularly  by  a  qualified 

professional,

 

î

Comply with all the instructions and recom-

mendations provided in the appliance docu-

mentation,

 

î

Make sure to receive from the installer all 

the necessary explanations related to the 

operation of the appliance and the safety 

devices,

 

î

Make sure to receive from the installer all the 

appliance and accessories documentation,

 

î

Keep all the appliance documentation in a 

safe place for future use.

The end-user shall use the product for its intend-

ed use.

 

î

Should the installer or the end user not comply with the instructions and require-

ments stated in this manual, the warranty will be void. 

 

î

For more information on the warranty terms and conditions, please connect to 

our website: www.myaic.eu.

i

Summary of Contents for SILOX S

Page 1: ...h e a t i n g s y s t e m s EN installation and maintenance manual FOR THE INSTALLER AND THE USER 90 130 190 260 400 600 1000 L DOMESTIC HOT WATER STAINLESS STEEL TANKS I10_092 01 SILOX S SILOX S...

Page 2: ...operation of the appliance and the hydraulic system as well as the safety devices that are provided Any instruction regarding periodic checks to be performed and possible anomaly to be reported All t...

Page 3: ...ts 11 Recommendations for the Quality of Water Primary circuit 12 Hydraulic Connections 13 Commissioning 14 Filling the Tank 14 Starting Up 14 Maintenance 15 Safety Instructions and Recommendations 15...

Page 4: ...r injuries or death Indicates an important instruction which if not followed could re sult in a hazardous situation that could cause damage to equip ment and or injuries Indicates an essential instruc...

Page 5: ...or written consent of the manufacturer If components need to be replaced only genuine factory parts or compo nents approved by the manufacturer must be used When working on the appliance and the syste...

Page 6: ...and hole 2 Thermal insulation 3 Drywell for temperature sensor 4 DHW inner storage tank in stainless steel 5 Steel primary outer tank 6 Primary connection return 7 Base cover 8 Inspection hole 9 Dip t...

Page 7: ...170 182 182 182 192 336 D 575 980 777 1027 1512 1493 1926 Connections in SX90S SX130S SX190S SX260S SX400S SX600S SX1000S Cold water inlet M G 3 4 G 3 4 G 3 4 G 3 4 G 1 G 1 G 11 4 DHW outlet M G 3 4 G...

Page 8: ...pty weight Kg 35 51 64 78 106 151 239 Standing heat loss W 45 50 58 63 99 103 113 Energy efficiency class B B B B C C C Hydraulic Performance SX90S SX130S SX190S SX260S SX400S SX600S SX1000S Peak Flow...

Page 9: ...and temperatures of the primary circuit for DHW production from 10 C to 45 C Performance and pressure losses 86 Pressure losses between input and output connections of the primary circuit for differen...

Page 10: ...the electrical circuit isolate the electri cal supply of the appliance through the external power cutting device fuse circuit breaker etc All connections must be carried out in accordance with curren...

Page 11: ...appli ance power and the system size and the increase in temperature and pressure Using antifreeze in the primary circuit will reduce the heating performance The higher the concentration of antifreeze...

Page 12: ...eds to be refilled frequently check for leaks in the primary circuit Inhibitors may be used according to stand ard EN 14868 An air separator on the appliance supply circuit combined with a dirt separa...

Page 13: ...f tap DHW Outlet Isolating valve Cold water inlet Thermostatic mixing valve Pressure reducing valve Motorised spring return valve or manual valve From distribution network Make sure that your hydrauli...

Page 14: ...d 1 5 bar Follow on Task s Check that there are no leaks Start the boiler as required Refer to the Start up procedure opposite Always fill and pressurise the inner tank DHW before filling the outer pr...

Page 15: ...ne factory parts or parts approved by the manu facturer Replace any gaskets or seals present on the removed components before reinstallation unless otherwise speci ed in the procedures Operate manuall...

Page 16: ...is sound Gradually introduce the descaling agent until the correct amount is added for the volume of water Run the pump and monitor the pH value the pro cess is complete when the pH stabilises at less...

Page 17: ...an be extremely hot Use extreme care when draining a hot appliance Draining procedure Always drain depressurize the outer tank before draining the inner tank to prevent any deformation of the inner ta...

Page 18: ...refer to the heat generator manual The isolating valves of the primary circuit are closed 2 Open the isolating valves to allow prima ry water to fill the outer tank Make sure that the DHW in ner tank...

Page 19: ...uct Fiche AIC SILOX S Referring to Commission Delegated Regulation No 812 2013 Model Energy efficiency class Standing loss Volume SX90S B 45 W 80 l SX130S B 50 W 122 l SX190S B 58 W 187 l SX260S B 63...

Page 20: ...AIC Europe B V Graafschap Hornelaan 163A NL 6001 AC Weert The Netherlands www myaic eu...