Chapter 3 Sub-System configuration Setup
J4076-01 User's Manual
48
3.6.3.4 SES Vendor specific page: Canister Number ( page code 83h)
Out / In
The length N of canister number can be 0~30 bytes. If no canister
number is entered (N=0), then canister number is restored to default:
0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 (8 spaces in ASCII).
Canister Number control format
BYTE/BIT
7
6
5
4
3
2
1
0
0~N
Canister Number
If no canister number is found, return Status = 1 (failed) only, else return
Status=0 (success) followed by canister number.
Canister Number status format
BYTE/BIT
7
6
5
4
3
2
1
0
0
Status (0: success, 1: failed)
1~N
(if success)
Canister Number