![AIC J4076-01 User Manual Download Page 53](http://html1.mh-extra.com/html/aic/j4076-01/j4076-01_user-manual_2870764053.webp)
Chapter 3 Sub-System configuration Setup
J4076-01 User's Manual
46
3.6.3 Implementation on SES Pages
3.6.3.1 SES String In Page
Get PMBUS information with String In Page.
String In Format
Byte 0
I2C congestion status (0: no congestion, 1: congestion or
failure)
Byte 1~2 PSU Module1 STATUS_WORD
Byte 3~4 PSU Module2 STATUS_WORD
Byte 5~14 Reserved (0xFF)
3.6.3.2 SES Threshold Out / In
It includes only Temperature Sensor and Voltage Sensor elements.
Threshold control element format
BYTE/BIT
7
6
5
4
3
2
1
0
0
REQUESTED HIGH CRITICAL THRESHOLD
1
REQUESTED HIGH WARNING THRESHOLD
2
REQUESTED LOW WARNING THRESHOLD
3
REQUESTED LOW CRITICAL THRESHOLD
Threshold control element format
BYTE/BIT
7
6
5
4
3
2
1
0
0
HIGH CRITICAL THRESHOLD
1
HIGH WARNING THRESHOLD
2
LOW WARNING THRESHOLD
3
LOW CRITICAL THRESHOLD