49
Stingray Login via BMC SOL Function
Top Slot
Bottom Slot
NOTE
You also can use SSH to access Stingray.
3. Configure Stingray for testing
Execute the command below to setup the JBOF.
cd /usr/share/spdk/scripts
./spdk-target-setup.sh
After the configuration, the JBOF setup is complete and ready to be linked to the
host server.
4. Host Server Setup
Step 1
OS base on CentOS 7.6 kernel 4.16.11
Download Broadcom 100G LAN adapter driver from the Broadcom website.
https://docs.broadcom.com/docs/NXE_Linux_Driver_installer_214.0.150.0
rmmod bnxt_en
rmmod bnxt_re
modprobe rdma_ucm
modprobe nvme_rdma
Extract LAN adapter driver.
cd /bnxt_1.9.2-214.0.150.0\bnxt_1.9.2-214.0.150.0\Linux\KMP-L2-RoCE\KMP\
Novell\sle11sp4
Extract broadcom-bnxt_en-1.9.2.214.0.150.0-100R.6.1.src.rpm
cd /bnxt_en-1.9.2-214.0.150.0
rmmod bnxt_en
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol deactivate
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin raw 0x36 0x54 0x0
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol set non-volatile-bit-rate 115.2
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol set volatile-bit-rate 115.2
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol info
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol activate
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol deactivate
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin raw 0x36 0x54 0x1
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol set non-volatile-bit-rate 115.2
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol set volatile-bit-rate 115.2
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol info
ipmitool -I lanplus -H 192.168.11.11 -U admin -P admin sol activate