AIC J2024-01 User Manual Download Page 1

D/N:MAN-00304-C

P/N: H882JKC000-00010-?

J2024-01

SAS/SATA JBOD SERIES
User's Manual

Summary of Contents for J2024-01

Page 1: ...D N MAN 00304 C P N H882JKC000 00010 J2024 01 SAS SATA JBOD SERIES User s Manual...

Page 2: ...r Module 12 2 6 Removing and Installing the HDD backplane Module 13 2 7 Installing Slide Rail Adjuster Plate 14 Chapter 3 Sub System Configuration Setup 17 3 1 Supported Configuration On Host 17 3 2 U...

Page 3: ...Copyright 2015 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Page 4: ...eption It is essential that only the supplied power cord be used 2 Use only shielded cables to connect I O devices to this equipment 3 You are cautioned that changes or modifications not expressly app...

Page 5: ...unit chassis for a few seconds This will help to discharge any static electricity on your body Place this equipment on a stable surface when install A drop or fall could cause injury Please keep this...

Page 6: ...ipment 3 The equipment has been exposed to moisture 4 The equipment does not work well or will not work according to its user manual 5 The equipment has been dropped and or damaged 6 The equipment has...

Page 7: ...remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify that the contents of the shipping carton are...

Page 8: ...A C Input 100 240V AC full range Temperature 0 C to 35 C Relative humidity 20 to 80 Temperature 20 C to 60 C Relative humidity 10 to 90 Dimensions W x D x H mm 483 x 511 x 88 inches 19 x 20 x 3 5 Gros...

Page 9: ...ckmount chassis with 24 x 2 5 HDD hot swap bay and dual expand module JBOD which is a high performance high density scalable storage product The J2024 01 JBOD supports T10 zoning function and can be s...

Page 10: ...l Chapter 1 Product Introduction Rear Expender Panel 2 Dual Expander Primary Secondary BMC console port BMC LAN port option SFF 8644 wide port BMC LAN port option SFF 8644 wide port Console port Debug...

Page 11: ...5 J2024 01 User s Manual Chapter 1 Product Introduction Rear Panel...

Page 12: ...to know how your enclosure works For detailed information please visit http www t10 org If you are a member of the T10 working group the Standard which controlled by T10 technical committee could be f...

Page 13: ...er s Manual 7 2 1 Removing and Installing Top Cover Loosen 5 screws on top cover Take it out of the enclosure Chapter 2 Hardware Installation This chapter provides detailed instructions on hardware in...

Page 14: ...inching the lock lever slightly and pulling out the drive tray 2 2 Removing Installing a Drive Tray Hard Drive Drive Slot Map 2 2 2 Installing a Disk Drive Adjust and place the 2 5 HDD on the HDD tray...

Page 15: ...ng a Hard Disk Drive Tray Insert the drive carrier into its bay Push the tray lever until it clicks Make sure the drive tray is correctly secured in place when its front edge aligns with the bay edge...

Page 16: ...dule Remove power cables connected to the PSU module Allow a minute for fan to spin down Pushing the latch then hold the tray handle tab Then pull the PSU module gently until it slides out of the JBOD...

Page 17: ...oving a Fan module Loosen the thumb screws on each sides in front of fan module Hold the fan module from both sides Pull the fan module gently and firmly until it clears the enclosure chassis 2 4 2Ins...

Page 18: ...moving an expander module Loosen the thumb screw to release expander tray lever Hold the lever to pull the expander out of JBOD 2 5 2 Installing an expander module Align the expander module with the o...

Page 19: ...e module Unscrew 8pcs screws in the middle side of JBOD to release the HDD backplane module 2 top side 2 bottom side 2 both side Hold the backplane module to pull the backplane module out of JBOD 2 6...

Page 20: ...7 Installing Slide Rail Adjuster Plate 7 Slide Rail Installation User s Manual Screws kit The direction of pull the slide rail out 1 2 3 4 7 4 0 1 0 0 55 5 6 2 7 1 Installing slide rail To install the...

Page 21: ...Installing the rear of JBOD onto the Rack Secure the adjuster plate on the rack using the screws Insert the slide rail into the adjuster plate and make sure the slide rail is fully hooked into the adj...

Page 22: ...Chapter 2 Hardware Installation J2024 01 User s Manual 16 2 7 3 Installing the front of JBOD onto the rack Secure the JBOD on the rack using the screws Complete installing JBOD...

Page 23: ...roller Other Expander 1 Each AIC Expander Controller Host Other Expander 2 Each AIC 12G Expander Controller 3 Host 1 Host n note To have multiple host access support the host number can be up to the n...

Page 24: ...3 2 Utility Set up on Host Step 1 Set up host RS232 connection Set up RS232 connection application into your host as shown in the example process below For example OS Microsoft Windows Server 2008 RS2...

Page 25: ...3 Sub System configuration Setup Step 3 Enter a new name for the icon in the field below and click OK Step 4 Connect by using selecting an option in the drop down menu circled in red below we selected...

Page 26: ...he diagram below depicts what screen should displayed Step 5 For Bits per second select 38400 For Flow control select None Click OK when you have finished your selections Properties Port Setting Bits...

Page 27: ...21 Chapter 3 Sub System configuration Setup 3 3 Connect Host to JBOD via RS232 Use a RS 232 DB9 cable connect the console port of JBOD with host s PC COM port see figures below for DB9 RS 232 cable an...

Page 28: ...A Check the current zoning state cmd phyzone state Zoning is OFF B Enable zoning cmd phyzone on C Disable zoning cmd phyzone off cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd phyzone state Zoning is...

Page 29: ...first port and another drive accessed only by the second port The configuration for the example is A PHY0 PHY3 for the first wide port B PHY4 PHY7 for the second wide port C PHY12 PHY35 for drive Ste...

Page 30: ...eeded to set zone group for the phy cmd phyzone 6 9 Succeeded to set zone group for the phy cmd phyzone 7 9 Succeeded to set zone group for the phy cmd cmd cmd cmd cmd _ cmd phyzone 12 8 Succeeded to...

Page 31: ...d showmfg Manufacturing Image Version Information Mfg Revision 1 1 0 4 Product Name SAS3_HOTSWAP Platform Name AIC 12G cmd _ cmd sensor ENCLOSURE STATUS Total fan number 2 System Fan 0 speed 10888 RPM...

Page 32: ...reshold 54 C The new setting will take effect after reset cmd temperature 18 52 48 54 cmd reset C We also take expander temperature into consideration and the temperature parameters for expander are f...

Page 33: ...x500605B0000272BF B Set the enclosure address with 0x500605B0000272BF The new setting will take effect after reset cmd enclosure_addr 500605B0000272BF cmd reset cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd...

Page 34: ...er Standby Timer 0 minutes cmd _ 3 4 6 How to configure standby timer for all disk drives This feature is applicable for SAS SATA drives Standby timer is in units of minutes Setting standby timer with...

Page 35: ...attached SAS drives to save power consumption of SAS drives Otherwise AIC Expander Controller starts all attached SAS drives to provide drive access service to any active SAS initiator A Get the curre...

Page 36: ...md cmd cmd cmd check_wide_port on Succeeded to configure checking wide port cmd reset_ cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd cmd check_wide_port Checking wide port is OFF cmd _ cmd cmd cmd cmd cmd c...

Page 37: ...421 12021704510010 Enclosure number 526 12071100500088 B Only set Expander serial number with 421 12021704510010 cmd serial_number 421 12021704510010 C Set both of Expander serial number 421 12021704...

Page 38: ...a cable to connect your host with the expander We use Linux for example A Show the device for AIC Expander Controller canister sg_map i dev sg2 AIC 12G 2U24SAS3swap 0c01 B Get the current state of a...

Page 39: ...J2024 01 User s Manual 33 Chapter 3 Sub System configuration Setup...

Page 40: ...Chapter 3 Sub System configuration Setup J2024 01 User s Manual 34...

Page 41: ...J2024 01 User s Manual 35 Chapter 3 Sub System configuration Setup...

Page 42: ...Chapter 3 Sub System configuration Setup J2024 01 User s Manual 36...

Page 43: ...J2024 01 User s Manual 37 Chapter 3 Sub System configuration Setup...

Page 44: ...isk drives Set the bit to power on all disk drives Please install the software package sg3_utils on your host computer and have a SAS HBA and a cable to connect your host with the expander We use Linu...

Page 45: ...J2024 01 User s Manual 39 Chapter 3 Sub System configuration Setup...

Page 46: ...Chapter 3 Sub System configuration Setup J2024 01 User s Manual 40...

Page 47: ...J2024 01 User s Manual 41 Chapter 3 Sub System configuration Setup...

Page 48: ...fan function again Please disable the smart fan function before changing PWM or fan speed Only Cooling element 0 supports this feature We use the software package sg3_utils on Linux for example and ha...

Page 49: ...J2024 01 User s Manual 43 Chapter 3 Sub System configuration Setup root localhost sg_map i dev sg2 AIC 12G 2U24SAS3swap 0c01...

Page 50: ...Chapter 3 Sub System configuration Setup J2024 01 User s Manual 44 sg_ses descriptor SystemCooingElement01 set 1 7 1 dev sg2...

Page 51: ...J2024 01 User s Manual 45 Chapter 3 Sub System configuration Setup sg_ses descriptor SystemCooingElement01 set 3 2 3 7 dev sg2...

Page 52: ...rs off all attached SAS SATA drives to save power consumption Otherwise AIC Expander Controller powers on all attached SAS SATA drives to provide drive access service to any active SAS initiator A App...

Page 53: ...ring on AC power loss Three supported options are keep off keep on and keep last state The default setting is keep off A Get the current power setting cmd power_setting Power setting keep off B Set ke...

Page 54: ...d cmd edfb EDFB is OFF cmd edfb on Succeeded to set EDFB cmd _ cmd cmd cmd cmd edfb EDFB is OFF cmd edfb on Succeeded to set EDFB cmd edfb off EDFB is OFF cmd _ 3 4 14 How to enable the EDFB function...

Page 55: ...e command was sent to the enclosure that means the enclosure accepts the command sent by the host The reference script below runs on Linux bin bash PORT dev ttyS0 BAUDRATE 9600 NOFLOW ixon ixoff crtsc...

Page 56: ...Chapter 3 Sub System configuration Setup J2024 01 User s Manual 50 stop echo RemoteStop echo e n PORT echo e RemoteStop n PORT echo e RemoteStop n PORT...

Page 57: ...J2024 01 User s Manual 51 Chapter 4 BMC Configuration and Setting 4 1 Sensor s location for Fan Temperature Chapter 4 BMC Configuration and Settings Fan1 FRONT Fan0 T0...

Page 58: ...2024 01 User s Manual 52 4 2 Utility setup on Host Please refer to Section 3 2 4 3 Connect Host to BMC by RS232 1 Type the it will show the IPMI serial interface Type command for login the interface s...

Page 59: ...HCP 30 00 02 01 04 00 00 Get LAN IP 30 00 02 01 03 00 00 Get submask 30 00 02 01 06 00 00 Get gateway 30 00 02 01 0C 00 00 Get LAN static IP DHCP 01 is static IP 02 is DHCP The red box is hexadecimal...

Page 60: ...P 30 00 01 01 04 01 02 Set LAN IP 30 00 01 01 03 C0 A8 00 0A Set submask 30 00 01 01 06 FF FF FF 00 Set gateway 30 00 01 01 0C C0 A8 00 01 The Green returns text that in red box is completion code 00...

Page 61: ...J2024 01 User s Manual 55 Chapter 4 BMC Configuration and Setting 4 Login the web page Open a browser type the IP in the address bar Type the default account and password Account admin Password admin...

Page 62: ...to reload the console preview Sensor Monitoring It lists all available sensors on the device with information such as status name reading and status icon as well as a link to that sensor s page There...

Page 63: ...ng Chassis information fields Area Format Version Chassis Type Chassis Part Number Chassis Serial Number Chassis Extra Board Information It displays the following Board information fields Area Format...

Page 64: ...s page displays all the HDD power on off status using the Power On and Power Off button to control HDD status ACTIONS Power On Select a HDD to turn it power on Power off Select a HDD to turn it power...

Page 65: ...al representation of all associated events Double click on a record to toggle ON OFF the live widget for that particular sensor You can filter the list to view particular sensors only using the drop d...

Page 66: ...n the device BMC Timezone Check this option to display the event log entries logged with the BMC Timezone value Client Timezone Check this option to display the event log entries logged with the Clien...

Page 67: ...the device Register BMC Choose the BMC s network port to register with the DNS settings Check the option Register BMC to register with the DNS settings Choose the option Direct Dynamic DNS to register...

Page 68: ...server DNS Server 1 2 3 Specify the DNS Domain Name System server address to be configured for the BMC An IPv4 Address is made of 4 numbers separated by dots as in xxx xxx xxx xxx Each number ranges...

Page 69: ...only IPv4 Configuration It lists the IPv4 configuration settings Obtain an IP address automatically Enable Use DHCP to dynamically configure the IPv4 address using Dynamic Host Configuration Protocol...

Page 70: ...iguration Protocol DHCP IPv6 Address Specify a static IPv6 address to be configured for the selected interface Subnet Prefix length Specify the subnet prefix length for the IPv6 settings Value ranges...

Page 71: ...e are to be configured Auto Negotiation This option is enabled to allow the device to perform automatic configuration to achieve the best possible mode of operation speed and duplex over a link Link S...

Page 72: ...he device Date Specify the current Date for the device Time Specify the current Time for the device NTP Server Specify the NTP Server for the device Check the Automatically synchronize option to confi...

Page 73: ...e used to display the exact local time Check this option to automatically synchronize Date and Time with the NTP Server Refresh Click Refresh to reload the current date time settings Save Click Save t...

Page 74: ...lter configurations Alert Policy Click the Alert policy tab to show configured Alert policies and available slots You can modify or add new alert policy entries here A maximum of 60 slots are availabl...

Page 75: ...double click on a free slot Modify Select a configured slot and click Modify to modify that entry Alternatively double click on the configured slot Delete Select the desired configured slot to be del...

Page 76: ...Machine Name is a string of maximum 15 alpha numeric characters Space special characters are not allowed Primary SMTP Server It lists the Primary SMTP Server configuration SMTP Support Check this opt...

Page 77: ...least 4 characters long Space is not allowed Secondary SMTP Server It lists the Secondary SMTP Server configuration It is an optional field If the Primary SMTP server is not working then it tries the...

Page 78: ...modified as a security measure To view the page you must have Operator privileges To modify or add a user You must have Administrator privileges Add User Select a free slot and click Add User to add a...

Page 79: ...s Reset Expander Select this option to reboot the expander without powering off warm boot Power Off Storage Select this option to immediately power off the storage Power On Storage Select this option...

Page 80: ...L Launch the Java SOL you must have Administrator privileges Volatile Bit Rate Please set 38 4K Non Volatile Bit Rate Please set 38 4K This function can connect to expander command line mode note A co...

Page 81: ...7 0 or later version Linux Redhat 6 4 4 5 2 Web update 1 Check the BMC IP is valid 2 Open a browser type in the BMC IP it will show the BMC web UI type the default account or have administrator privi...

Page 82: ...Chapter 4 BMC Configuration and Setting J2024 01 User s Manual 76 3 This is login main page 4 Click the Firmware Update it will pop a drop down menu click the Firmware Update...

Page 83: ...guration and Setting 5 This page will show the update warning if you really want to update BMC firmware click the Enter Update Mode button 6 Wait few minutes it will pop a window click the Select file...

Page 84: ...n and Setting J2024 01 User s Manual 78 7 Wait a minutes it will pop a window for check update section just check the Check this option to do all full firmware flash option 8 Click OK the firmware wil...

Page 85: ...and Setting 9 In the update processes it will take 3 5 minutes 10 When show the Device has been reset window it means firmware update successful wait 90 seconds for BMC restarted Caution Please do not...

Page 86: ...uration and Setting J2024 01 User s Manual 80 4 6 Expander firmware update 1 Click the Firmware Update it will pop a drop down menu click the Expand Update 2 Chose the expander firmware file then clic...

Page 87: ...J2024 01 User s Manual 81 Chapter 4 BMC Configuration and Setting 3 Click the Proceed button 4 Updating...

Page 88: ...MC Configuration and Setting J2024 01 User s Manual 82 5 Update finished and successful 6 If update processes not success please check the expander firmware is current version or the system is already...

Page 89: ...safety mode If you update process fail or primary firmware suffers some error it will boot in safety mode 1 If you saw the sensor name status LED and ID LED are abnormal the LEDs are cross blinking it...

Page 90: ...Chapter 4 BMC Configuration and Setting J2024 01 User s Manual 84...

Page 91: ...J2024 01 User s Manual 85 Chapter 4 BMC Configuration and Setting 2 Please clear browser cookies and re start browser BMC web UI will refresh web page object...

Page 92: ...Chapter 4 BMC Configuration and Setting J2024 01 User s Manual 86 3 Click the BMC Reset button into the reset page 4 Select the BMC reset and Click the Perform Action button...

Page 93: ...troduction 5 The page will show Requesting status because reset BMC this web page will be invalid wait 90 seconds and clear browser cookies re login web UI again 6 If still see the safety mode page pl...

Page 94: ...tw CHINA Tel 86 21 54961421 86 21 54961422 Fax Extension 608 Email Technical Support support aicipc com AMERICA West coast Tel 1 909 895 8989 Fax 1 909 895 8999 Email sales aicipc com AMERICA East coa...

Reviews: