Default value: 50 (50W)
Parameter size: 2 [byte]
Parameter No.17 T
he value here represents minimum change in wattage percent (in terms
of percentage) for a meter report (watt) to be sent
When the change value of the load power
exceeds the setting value, smart plug will send
meter report
to associated device (Group Lifeline).
Possible values:
-128 - 127 (0 - 255%)
-128 to -1
:
255% to 128%
1 to 127: 1% to 127%
0 - The function is disabled.
Default value: 10 (10%)
Parameter size: 1 [byte]
Parameter NO.100 Setting the parameters 101~104 to default.
Possible values: 85
Parameter size: 1 [byte]
Parameter No. 101 Setting time for sending meter report (watt)
The interval time of sending meter report (watt) to associated device (Group Lifeline).
Possible values:
5- 2678400 (5 - 2678400s)
Default value: 600(10 minutes).
Parameter size: 4 [byte]
Parameter No. 102 Setting time for sending meter report (KWh)
The interval of sending meter report (KWh) to association device (Group Lifeline).
Possible values:
5- 2678400 (5 - 2678400s)
Default value: 3600(one hours).
Parameter size: 4 [byte]
Parameter No. 103 Setting time for sending meter report (voltage)
The interval of sending meter report (voltage) to association device (Group Lifeline).