Default value: 50 (50W) 
Parameter size: 2 [byte] 

 

Parameter No.17 T

he value here represents minimum change in wattage percent (in terms 

of percentage) for a meter report (watt) to be sent 

When the change value of the load power 

exceeds the setting value, smart plug will send 

meter report 

to associated device (Group Lifeline).

 

 
Possible values: 

-128 - 127 (0 - 255%) 

-128 to -1

255% to 128% 

1 to 127: 1% to 127% 
 
0 - The function is disabled. 
 
Default value: 10 (10%) 
Parameter size: 1 [byte] 

 

Parameter NO.100 Setting the parameters 101~104 to default. 
 

Possible values: 85 

Parameter size: 1 [byte] 
 
Parameter No. 101 Setting time for sending meter report (watt) 
The interval time of sending meter report (watt) to associated device (Group Lifeline). 
 

Possible values: 

5- 2678400 (5 - 2678400s) 
 
Default value: 600(10 minutes). 
Parameter size: 4 [byte] 
 
Parameter No. 102 Setting time for sending meter report (KWh) 
The interval of sending meter report (KWh) to association device (Group Lifeline). 
 

Possible values: 

5- 2678400 (5 - 2678400s) 
 
Default value: 3600(one hours). 
Parameter size: 4 [byte] 
 
Parameter No. 103 Setting time for sending meter report (voltage) 
The interval of sending meter report (voltage) to association device (Group Lifeline). 

Summary of Contents for HA-ZW-5PAB

Page 1: ...ters regardless of vendor to increase reliability of the network Smart Plug is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want yo...

Page 2: ...ht is blue when the device is turned off the light changes to red 2 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Rated load current 10A Power consumption 1 5W Power output 2300W Operational temp...

Page 3: ...frame 2 To remove the product from the Z Wave network a Insert the Smart Plug to power socket the LED will follow the status on or off of its load s power level b Set the Z Wave network main controlle...

Page 4: ...V2 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2...

Page 5: ...ommand such as short pressing 2 Sending Meter Report 3 Sending Device Reset Locally 5 2 Basic Command Basic CC maps to Switch Binary CC 5 3 Configuration Command Smart Plug offers a wide variety of ad...

Page 6: ...0 The function is disabled 1 Send Basic report 2 Send Basic report only when Load status is not changed by Z Wave Command Default value 1 Parameter size 1 byte Parameter No 04 LED Load indicator mode...

Page 7: ...the parameters 101 104 to default Possible values 85 Parameter size 1 byte Parameter No 101 Setting time for sending meter report watt The interval time of sending meter report watt to associated devi...

Page 8: ...ssible values 5 2678400 5 2678400s Default value 3600 one hours Parameter size 4 byte Parameter No 254 Enable disable the configuration command Lock unlock all configuration parameters Possible values...