COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
5. NOTE FOR SPECIAL COMMANDS
5.1 Association Command
The Smart Plug supports only one association group.
Grouping
Identifier
Max Nodes
Send Commands
Group 1
0x05
1. When the state of Smart Plug (turn on or off the load) is changed:
1. Set Configuration parameter 24 to 0: Reserved
2. Set Configuration parameter 24 to 1: Send Basic Report
3. Set Configuration parameter 24 to 2: Send Basic Report
only
when Load condition is changed not by Z-Wave Command,
such as short pressing.
2. Sending Meter Report.
3. Sending Device Reset Locally.
5.2 Basic Command
Basic CC maps to Switch Binary CC
5.3 Configuration Command
Smart Plug offers a wide variety of advanced configuration settings. Below parameters can be
accessed from main controller’s configuration interface.
NOTE: ALL NUMBERS BELOW ARE DECIMAL.
Parameter No. 01 Overcurrent protection
Smart Plug keep detecting the load power, once the AC current exceeds 11 A for more than 4
seconds, smart plug's relay will turn off.
Possible values:
0 - The function is disabled
1 - The function is enabled.
Default value: 1
Parameter size: 1 [byte]
Parameter No.
02 Setting device status after power failure
Define how Smart Plug reacts after the power supply is back on.