2.5 CORRECTION FACTORS
Correction factor for operating pressure changes :
Inlet air pressure
psig
60
80
100
120
140
160
180
200
barg
4
5.5
7
8
10
11
12.5
14
Factor (F1)
0.79
0.91
1.00
1.07
1.13
1.18
1.23
1.27
Correction factor for ambient temperature changes:
Ambient temperature ºF
≤
80
90
100
105
110
115
120
ºC
≤
27
32
38
40
43
46
50
Factor (F2)
1.22
1.11
1.00
0.94
0.89
0.83
0.78
Correction factor for inlet air temperature changes:
Air temperature
ºF
≤
140
160
170
180
195
210
ºC
≤
60
70
76
82
90
100
Factor (F3)
1.26
1.13
1.07
1.00
0.90
0.81
Correction factor for DewPoint changes:
DewPoint
ºF
37
41
45
50
ºC
3
5
7
10
Factor (F4)
0.78
0.90
1.00
1.12
How to find the air flow capacity:
How to select a suitable dryer for a given duty:
Air flow
capacity
=
X
Factor
(F1)
Factor
(F2)
X
Factor
(F3)
X
X
Factor
(F4)
Nominal
duty
=
÷
Factor
(F1)
Factor
(F2)
÷
Factor
(F3)
÷
÷
Factor
(F4)
Design
air flow
Std. air
flow rate
Minimum
Example:
Example:
An
AHT 150
has a nominal duty of
150 scfm
(255 m
3
/h)
. What is the maximum allowable flow
through the dryer under the following operating
conditions:
−
Inlet air pressure = 120 psig (8 barg)
−
Ambient temperature = 105°F (40°C)
−
Inlet air temperature = 195°F (90°C)
−
Pressure DewPoint = 45°F (7°C)
Each item of data has a corresponding numerical
factor as follows:
The procedure here is to list the operating
conditions and then to locate the corresponding
numerical factors:
−
Design air flow = 95 scfm (161 m
3
/h)
−
Inlet air pressure = 120 psig (8 barg)
−
Ambient temperature = 105°F (40°C)
−
Inlet air temperature = 195°F (90°C)
−
Pressure DewPoint = 45°F (7°C)
In order to select the correct dryer model the
required flow rate is to be divided by the correction
factors relating to above mentioned parameters:
=
137 scfm
→
This is the maximum flow
rate that the dryer can accept under these
operating conditions.
=
104 scfm
→
Therefore the model suitable
for the conditions above is
AHT 150
(
150 scfm
or
255 m
3
/h
- nominal duty).
=
x
x
x
x
1.07
150
0.94
1.00
0.90
capacity
Air flow
=
÷
÷
÷
÷
1.07
95
0.94
1.00
0.90
flow rate
Minimum
Summary of Contents for 20-350
Page 29: ...7 1 1 AHT 20 50 AC 7 1 2 AHT 75 AC 7 1 3 AHT 100 150 AC ...
Page 30: ...7 1 4 AHT 200 250 AC 7 1 5 AHT 300 350 AC ...
Page 31: ...7 2 1 AHT 20 50 ...
Page 32: ...7 2 2 AHT 75 ...
Page 33: ...7 2 3 AHT 100 ...
Page 34: ...7 2 4 AHT 150 ...
Page 35: ...7 2 5 AHT 200 250 ...
Page 36: ...7 2 6 AHT 300 350 ...
Page 41: ...NOTE ...
Page 42: ...NOTE ...
Page 43: ...NOTE ...
Page 44: ...GRAMAGLIA GO ...