background image

27 

13.3  Index 

Accessories

 .............................. 26 

additional channels .................... 14 
AMR-Control .............................. 10 
Battery operation ....................... 12 
code switches ............................ 17 

Code switches

 ............................ 2 

Combination key ........................ 16 
Configuration.............................. 17 
Connecting the transducers ....... 14 

Connection socket DC

 .............. 2 

Data buffering ............................ 13 
Device address .......................... 17 

Device-internal channels

 ........ 14 

Device-internal  measured  value 
memory ...................................... 19 
differential channel ..................... 14 

electrically isolated

 .................. 15 

External DC voltage supply ....... 12 
file name .................................... 20 
Functions of the ALMEMO

®

 8590-9

 ..................................................... 6 

Ground socket

............................ 2 

Housing

 ..................................... 26 

Initial commissioning ................... 11 
Introduction .................................. 6 

Key

 .............................................. 2 

linearization

 .............................. 21 

Mains operation ......................... 12 
Measured data acquisition ......... 18 
Measuring inputs ................. 14, 26 

Measuring inputs

 ....................... 2 

Measuring operations .................. 8 
Memory connector ..................... 20 
Micro SD card ............................ 20 
multi-point calibration ................. 21 

networking .................................. 17 
Offline measurement .................. 18 
Online measurement with PC .... 18 
Operating controls ........................ 2 
option KL .................................... 21 

Options

 ...................................... 26 

Order no.

 ................................... 26 

Output sockets

 ........................... 2 

Potential separation ................... 15 
Power supply ........................ 12, 26 
Process control ............................ 9 

Product overview

 ..................... 26 

read out the measured data

 .... 18 

rechargeable batteries ........... 5, 12 
rechargeable battery pack............ 6 
rechargeable battery pack.......... 26 
Reinitialization ............................ 13 
Scope of delivery .......................... 5 
Sensor programming .................... 7 
Sensor supply ............................ 13 
Sleep mode ................................ 19 
socket 

DC

 ................................... 12 

Software ..................................... 10 

Special measuring ranges

....... 21 

Standard equipment

 ................ 26 

start  and  stop  a  measuring 
operation

 ................................... 18 

Status LEDs

 ................................ 2 

Suitable conditions

 .................. 26 

Switching ON / OFF ................... 13 
Technical data ............................ 26 
Transducer ................................. 14 
Trouble-shooting ........................ 22 
Warranty ....................................... 4 
WIN-Control................................ 10 

 

Summary of Contents for ALMEMO 8590-9

Page 1: ...____________________________ Operating instructions English Data acquisition modules ALMEMO 8590 9 and 8690 9A V1 6 26 01 2022 www ahlborn com...

Page 2: ...ets A1 A2 A1 USB Interface ZA1919DKU Interface optic fib ZA1909DK5 L RS 422 ZA 5099 NVL NVB Ethernet ZA 1945 DK Bluetooth ZA 1709 BTx Trigger input ZA 1000 ET EK Relay outputs ZA 1000 EGK Analog outpu...

Page 3: ...ial commissioning 11 6 Power supply 12 6 1 Mains operation 12 6 2 External DC voltage supply 12 6 3 Battery operation 8690 9A only 12 6 4 Sensor supply 13 6 5 Switching ON OFF 13 6 6 Data buffering 13...

Page 4: ...take the time to carefully read these operating instructions and the appropriate sections in the ALMEMO Manual This is absolutely necessary to avoid oper ating and measuring errors and to prevent dama...

Page 5: ...the batteries have not yet been charged First of all therefore the batteries should be charged using the mains adapter provided continue charging until the CHARGE lamp goes out Rechargeable batteries...

Page 6: ...ual Ch 6 Complete list of interface commands with all the printouts Manual Ch 7 The operating instructions you are now reading cover only those features and controls that are specific to this device M...

Page 7: ...ument and to change sensors without the need for any extra settings Function channels Maximum minimum average values and differences from certain measuring points can be programmed as function channel...

Page 8: ...e continuously scanned at a rate of 10 mops measuring operations per second If there are a lot of measuring points involved the response time can be short ened by increasing the measuring rate accordi...

Page 9: ...tely logged using the real time clock with date function or in terms of the pure measuring time For the purposes of starting stopping a measuring operation the start stop date and time of day and or t...

Page 10: ...easured values and all programming parameters can be output to any peripheral equipment RS232 RS422 USB and Ethernet in terfaces are available via the appropriate interface cables Wireless communi cat...

Page 11: ...pen file terminal log enter file name Save Start measuring operation by actuating the Start button or pressing the START STOP key see Manual 6 6 Stop measuring operation by actuating the Stop button o...

Page 12: ...ically isolated from the transducers or if a larger input voltage range 10 to 30 V is required then an electrically isolated supply cable must be used either the ZB 3090 UK or for the ALMEMO 8690 9A b...

Page 13: ...5 Switching ON OFF To switch the device ON OFF the ON OFF key 2 must be pressed To switch OFF press the ON OFF key and hold down for approx 1 second After the device is switched off the real time clo...

Page 14: ...cated However ALMEMO sensors can if required provide up to 4 channels with 9 input sockets each so that alto gether 36 channels are available The additional channels can be used in par ticular for hum...

Page 15: ...ts are electrically isolated from one another by means photo voltaic relays A new feature on this device is the additional separation of the measuring inputs from CPU and power supply Between all inpu...

Page 16: ...hold down to switch OFF again If the device is on and a cycle has been programmed the same key can be used to start and stop a measuring operation The current operating status is clearly shown by the...

Page 17: ...1 to different device numbers Example Module address 01 0 1 In network operation consecutive numbers between 01 and 99 should be used this ensures that device 00 is not addressed unnecessarily in the...

Page 18: ...Offline measurement To perform offline measuring operations i e data logging in the device itself you need either option S with a 500 KB EEPROM in the device or an external memory connector with a mic...

Page 19: ...t scan and then switches off again 7 The measuring operation can be stopped by twice pressing key 2e Func tion ON and STOP In this way any number of measuring operations can be performed in sleep mode...

Page 20: ...only the last file can be read No selective data output according to date and time or by number The memory connector with the additional memory card can be connected at socket A2 it is recognized auto...

Page 21: ...ort points can be programmed to the EEPROM in the ALMEMO connector using the AMR Control software menu Measuring points list Pro gram measuring point Measuring point multi point calibration special li...

Page 22: ...air or phantoms for thermocouples short circuit AB for PT100 sensors use 100 and check Connect the sensors again one at a time and check successively If a fault persists for any one connection then c...

Page 23: ...the computer see above Check the wiring for short circuit or crossed wires Are all network distributors supplied with power Network the devices again one at a time and check successively see above If...

Page 24: ...24 12 DECLARATION OF CONFORMITY...

Page 25: ...12 Declaration of conformity 25...

Page 26: ...50 C storage temperature 20 to 60 C Ambient relative humidity 10 to 90 rH non condensing 13 2 Product overview Order no Data acquisition module ALMEMO 8590 9 9 inputs maximum 40 channels 2 outputs ca...

Page 27: ...s 14 26 Measuring inputs 2 Measuring operations 8 Memory connector 20 Micro SD card 20 multi point calibration 21 networking 17 Offline measurement 18 Online measurement with PC 18 Operating controls...

Page 28: ...Mess und Regelungstechnik GmbH Eichenfeldstra e 1 83607 Holzkirchen Germany internet http www ahlborn com e mail amr ahlborn com Despite great care incorrect information cannot be ruled out Technical...

Reviews: