Safety instructions 

4. SAFETY INSTRUCTIONS

DANGER

Danger to life and limb, risk of damage to equipment 
Before starting to operate the device, please read the in-
structions carefully. 
Please ensure that you comply with all general safety advi-

ce   and   the   special   safety   instructions   included   in   other
chapters.

Such risks may occur in the following circumstances:

Failure   to   heed   the   operating   instructions   and   all   the

safety notes these contain 

Any form of unauthorized tampering or alteration inside

the device 

Use   of   the   device   in   environments   or   conditions   for

which it is not suited 

Use of the device with an unsuitable power supply and /

or in conjunction with unsuitable peripheral equipment 

Use of the device  for any purpose other than that for

which it is intended 

Damage caused by electrostatic discharge or lightning.

DANGER

Risk of fatal injury through exposure to dangerously high

voltage

Such risks may occur in the following circumstances:

Use of the device with an unsuitable power supply and /
or in conjunction with unsuitable peripheral equipment 

Damage caused by electrostatic discharge or lightning 

Do  not  run  sensor  lines  in  the  vicinity  of  high-voltage

power cables. 

Before you touch any sensor lines, ensure that all static

electricity has been discharged.

DANGER

Warning - explosive atmospheres or substances

In the vicinity of various fuels or chemicals there is a risk of ex-
plosion. 

Do not use the device in the vicinity of blasting work or filling

stations.

 ALMEMO

®

 809

7  

Summary of Contents for ALMEMO 809

Page 1: ...____________________________ Operating instructions Measured data acquisition module ALMEMO 809 V1 2 10 11 15 www ahlborn com...

Page 2: ...easuring sockets M0 to M8 M0 M8 for V5 V6 D6 D7 sensors M0 1 M8 9 max 81 channels 5 Output sockets A1 A2 A1 USB interface ZA1919 DKU RS232 optic fiber ZA1909 DK5 DKL RS 422 ZA 5099 NVL NVB Ethernet ZA...

Page 3: ...a buffering 17 8 CONNECTING SENSORS TRANSDUCERS 17 8 1 Standard sensors V5 V6 17 8 2 D6 sensors 18 8 3 D7 sensors 18 8 4 Measuring inputs additional channels 19 8 5 Potential separation 19 9 OPERATION...

Page 4: ...2 Table of Contents 14 ANNEX 29 14 1 Technical data 29 14 2 Index 30 14 3 Your contact partner 32 4 ALMEMO 809...

Page 5: ...ry device before leaving our factory undergoes numerous quali ty tests We provide a guarantee lasting two years from delivery date that your device will function trouble free Before returning your dev...

Page 6: ...such item as unsor ted domestic waste is strictly forbidden Please dispose of all packaging materials in accordance with the applicable national waste management regulations Please dispose of cardboa...

Page 7: ...conjunction with unsuitable peripheral equipment Use of the device for any purpose other than that for which it is intended Damage caused by electrostatic discharge or lightning DANGER Risk of fatal...

Page 8: ...n the connector itself repeated programming is thus no longer necessary Any sensor or output module can be connected to any ALMEMO measuring instru ment all in the same way However the new generation...

Page 9: ...outs Manual Chapter 7 he operating instructions you are now reading cover only those features and controls that are specific to this device Many sections refer to more detailed descriptions in the Man...

Page 10: ...connect an increasing ran ge of sensors to the ALMEMO V7 measuring instrument and to change sensors without needing to reset Function channels Maximum minimum average and differential values of certai...

Page 11: ...valuate double sensors individually scaled sensors and sen sors with function channels All activated V6 measuring channels are conti nuously scanned at a rate of 10 MOPS measuring operations per secon...

Page 12: ...vidually per scan cycle this can be adjusted to suit the fastest acting sensors slower acting ones being omitted until new updated values appear A measuring operation can be started and stopped by mea...

Page 13: ...ternal memory connector available as an accessory files can be read out very quickly via any standard card reader Numbering of measuring operations By entering a number single scans or entire series o...

Page 14: ...alue memo ry Using the integrated terminal measuring operations can also be performed online The WINDOWS software package WinControl is provided for measu red value acquisition from networked devices...

Page 15: ...log and then enter file name Save Start measuring operation by actuating the Start button or pressing the START STOP key see Man 6 6 Stop measuring operation by actuating the Stop button or pressing t...

Page 16: ...steht bei Netzbetrieb eine F hlerversorgungsspannung von 12V 400mA zur Verf gung selbstheilende Sicherung 500 mA Andere Spannungen 12V 15V 24V oder Referenzen f r Potentiometer und Dehnungsmessstreife...

Page 17: ...mechanical coding system ensures that sensors and output modules can only be connected to the correct sockets All ALMEMO plugs incorporate two snap lock levers these snap into position as soon as the...

Page 18: ...nd for analog sensors but offer substantially enhanced properties The conversion rate can be set from 1 milli second up to several minutes with a resolution up to 8 digits The number of channels has t...

Page 19: ...must therefore either be insulated e g by air spacing or lie at the same potential and any unequal potentials that do exist must be electrically isolated The nine analog inputs on this device are elec...

Page 20: ...ore be used with a small adapter cable ZA D700 GT this provides electrical isolation for the pow er supply and data lines Such problems do not affect sensors without a con ductive connection Non insul...

Page 21: ...easured values are transmitted to the PC per scan cycle REC is lit continuously Data is being saved to device memory per cycle This also lights up during output from memory REC flashes Data is being s...

Page 22: ...el and in full allows a much higher but also variable measuring speed With D7 sensors the individual scan time minimum 1 ms can be changed to a freely selectable longer preferred scan time The process...

Page 23: ...be performed on the selected measuring channel only Most D7 sensors provide this function for up to four primary chan nels This can be set similarly via the afore mentioned sensor menu see D7 sensor...

Page 24: ...hing the LEDs see 9 2 To read out the measured data select ALMEMO Control menu item De vices Measured value memory see Man 6 9 3 Here you can transfer to a file on the PC either the complete memory or...

Page 25: ...the system used for the memory card These files can be indivi dually selected and output The ring memory mode remains an available alter native see Man 6 10 13 2 However if the ring memory mode has b...

Page 26: ...changed since the last measuring operation a new file will be created and if no new file name has been programmed the index in the file name extension will automatically be in cremented by 1 e g ALME...

Page 27: ...in certain circumstances not behave quite as expected The cause of such unexpected behavior is not usually a device defect often the cause is incorrect operation by the user an invalid setting or unsu...

Page 28: ...LF is returned as echo If transmission is still not possible unplug the networked devices Check all devices individually on the data cable to the computer see above Check the wiring for short circuit...

Page 29: ...90 channels two outputs cascadable interface one key real time clock housed in an 8 DU case 8 MB flash memory mains unit 12 V 1 A MA 809 Options KL Linearization multi point calibration OA 809 KL R M...

Page 30: ...omagnetic compatibility 13 28 External DC voltage supply 7 2 16 file name 10 2 3 26 Functions of the ALMEMO 809 5 1 9 Ground socket 1 2 Housing 14 1 29 Introduction 5 8 Key 1 2 Linearization 11 26 Mai...

Page 31: ...sor programming 5 1 1 10 Sensor supply 7 3 16 Sleep mode 10 2 1 24 smoothing 9 4 23 socket DC 7 1 16 Software 5 1 3 14 Special measured quantities 11 26 Standard delivery 3 2 6 Standard equipment 14 1...

Page 32: ...14 Annex 14 3 Your contact partner Ahlborn Mess und Regelungstechnik GmbH Eichenfeldstra e 1 3 D 83607 Holzkirchen GERMANY Internet http www ahlborn com e mail amr ahlborn com 32 ALMEMO 809...

Reviews: