AGRETO PFM II
© AGRETO electronics GmbH
page:7
6
Installation
6.1
Positioning of the sensor in round balers
Select to install the sensor a vacancy in the lower third in a side wall of the
compression chamber or the tailgate (left or right), which is accessible for
installation even from the outside.
6.2
Positioning of the sensor in square balers
Select to install the sensor a vacancy at half height and 0.5 m before the end of
the bale chamber in a sidewall of the bale chamber, which is accessible for
installation even from the outside. If the pressed material is cut on one side,
mount the sensor on the other side, where the material to be pressed is not cut.
6.3
Installation of the sensor plate and the sensor cable
Hold the sensor plate to the desired location
Use the sensor plate as a template, mark the 4
holes with a pen.
Drill the 4 holes using a drill in a first step with
about 4 to 6 mm in diameter.
Drill the holes in a second step using a drill with
12 mm diameter.
Deburr the 4 holes inside and outside with a
Countersink or other suitable tool.
Insert the four screws through the holes of the
sensor plate and slide the 4 small insulating
plastic over the screws.