26
AGM Global Vision
3.2 MAINTENANCE
3.2.1 GENERAL
The Victrix operator maintenance consists of operational tests, inspections for unit serviceability,
cleaning and mounting procedures, corrective actions (troubleshooting and replacement
of a limited number of parts). Maintenance instructions covered elsewhere in this manual
(troubleshooting, etc.) are not repeated in this section.
CAUTION:
The Victrix is a precision electro-optical instrument and must be handled carefully at all times to
prevent damage.
CAUTION:
DO NOT dismantle the equipment.
3.2.2 CLEANING PROCEDURES
Clean the Victrix and optional items as follows:
1. Gently brush off any dirt from the equipment using only a clean, soft cloth.
2. Moisten the cloth with fresh water and gently wipe the external surfaces (except for optical
surfaces).
3. Dry any wet surfaces (except for optical surfaces) with another clean, dry soft cloth.
4. Using a lens brush, carefully remove all loose dirt from optical surfaces (objective lens and
output lens).
5. Slightly dampen a cotton swab with alcohol and gently wipe optical surface. Clean the optical
surface using circular movements, starting from the center and moving out towards the edge.
Do not touch the lens holder. Change the cotton swab after each circular stroke. Repeat until the
optical surface is clean.
6. Clean the battery contact surfaces and contact springs with a pencil eraser and/or alcohol and
cotton swabs.
CAUTION:
Thoroughly dry all items before placing them into the storage/carrying case.