MENU ITEM

SYMBOL

OPTION

FUNCTION

FFC

Auto / 

Manual /

External

Select the Flat Field 

Correction (FFC) mode.

CVBS

OFF

Turn on and off the CVBS 

Output function to view the 

video on CVBS monitor.

ON

DPC

---

Correct dead pixel manually.

BURN 

PREVENTION

ON

Turn on and off the Burn 

Prevention function.

OFF

VERSION

---

View the firmware version 

number and serial number.

RESTORE

---

Restore the device to 

defaults.

AUTO POWER 

OFF

OFF/30 min/ 

45 min

Set the automatic shutdown 

time.

LANGUAGE

17 Languages Select the language of 

interface.

TRAJECTORY

5 Profiles

One shot zero correction.

TIME SYNC.

Time Format / 

Time / Date

Set the time and date.

OSD

ON

Enable or disable OSD.

OFF

MEASURE

 

0.8 m/1.2 m/ 

1.8 m/3.0 m 

Target Height

Enter distance measurement 

mode. 

HOT TRACKING

OFF

Enable/disable hot spot mark 

(marking the spot of highest 

temperature).

ON

2.2.2  BATTERY TYPE

You can change the battery type according to your need. Select the correct 

battery voltage in the device menu.
1. Hold   button in the view mode to show the menu.
2. Select 

 Battery Voltage menu item, and press   button to switch the 

battery voltage. 

Summary of Contents for RATTLER TS19-256

Page 1: ...USER MANUAL RATTLER TS19 256 RATTLER TS25 256 THERMAL IMAGING RIFLESCOPE ...

Page 2: ...gulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export control laws In particular AGM Global Vision products may not be exported re exported or transferred to prohibited countries individuals organizations or entities including but not limited to those individ...

Page 3: ...o an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may ca...

Page 4: ...iption 7 1 2 Key Features 8 2 OPERATING INSTRUCTIONS 9 2 1 Basic Operations 9 2 2 Main Function 15 2 3 Client Software Introduction 22 3 MAINTENANCE 24 3 1 Maintenance 24 3 2 Troubleshooting 25 4 WARRANTY INFORMATION 26 4 1 Warranty Information and Registration 26 5 SPECIFICATIONS 28 5 1 Specifications 28 ...

Page 5: ...ible to take full advantage of this generous eye relief With hard recoiling rifles serious injury or even death can result from eyepiece impact with the shooter during the recoil process when discharging the firearm Be certain that your installation provides sufficient eye relief for the recoil generated by your rifle before shooting the firearm NOTE Give special attention to this warning when sho...

Page 6: ...batteries every two to three months WARNING When carrying or transporting the device put the protective lens cap on WARNING Condensation can cause fogging of the optical surfaces Condensation occurs when the temperature or humidity changes as follows When moving the device from cold to warm place or vice versa In places with high humidity When equalizing the temperature of the device with the envi...

Page 7: ...s clear image under harsh environment conditions like darkness fog smoke dust rain snow wood camouflage etc The device is used as a thermal rifle scope or handheld monocular The scope is mainly applied to scenarios such as patrolling and hunting etc TABLE 1 1 MAIN PARTS ITEM DESCRIPTION ITEM DESCRIPTION 1 Objective Lens 8 Battery Compartment 2 Objective Lens Сover 9 Eyecup 3 Objective Focus Ring 1...

Page 8: ...tal zoom Lightweight and compact design Easy to operate control panel Automatic or manual silent calibration Video recording and snapshot Built in EMMC memory 16 GB Various reticle types and colors Stadiametric rangefinder Adjustable color palettes Wi Fi data transmission Standby mode Waterproof shockproof Powered by two standard CR123A or RCR123A rechargeable batteries Up to 4 5 hours continuous ...

Page 9: ...d ready for use Clean all optical surfaces with a lens tissue 2 1 2 BATTERIES INSTALLATION CAUTION Verify that the equipment is OFF before remove the batteries To install the batteries refer to Figure 2 1 1 Turn the battery cover knob A counter clockwise and then open the battery cover B 2 Install two CR123A or RCR123A batteries C into the battery compartment Align the polarity symbols on the batt...

Page 10: ...necting the device to your PC or it may cause computer damage 1 Open the cable interface cover 2 Connect the device and power adapter with a Type C cable to power on the device Alternatively connect the device and PC to copy delete files 2 1 5 CONTROL BUTTONS The Rattler controls are shown in Figure 2 2 and are defined in Table 2 2 Each button is responsible for some functions selected by short pr...

Page 11: ...cle 2 1 6 POWER ON AND OFF Power On Hold the POWER button for 4 seconds to power on the device An image will appear on the display Refer to the figure below for the main view of the riflescope display Power Off When the device is turned on hold button for 4 seconds to power off the device In the Auto Power Off menu you can set the time for the automatic shutdown of the device as required OFF 30 mi...

Page 12: ...the temperature is the lighter the color is BLACK HOT The hot part is black colored in view The higher the temperature is the darker the color is FUSION The hot part is white colored From high temperature to low temperature the image is colored in from white yellow red pink to purple RED HOT The hot part is red colored in view The higher the temperature is the redder the color is 2 1 10 DIGITAL ZO...

Page 13: ...ries from the battery compartment before connecting the device to your PC or it may cause computer damage 1 Before connecting the thermal riflescope to a computer please make sure that the Wi Fi function of the riflescope is disabled 2 Connect the thermal riflescope to your PC with USB cable and open the detected disk 3 The directory is named by the current date Enter DCIM Date to view the videos ...

Page 14: ... device is firmly holding the Rattler If necessary adjust the clamping device s lever cam lock as detailed in part 2 1 17 Clamping Device Adjustment 2 1 17 CLAMPING DEVICE ADJUSTMENT To adjust the mount s clamping device do the following 1 Remove the Rattler from the weapon 2 With the clamping device unlocked as shown in Figure 2 5 push the cam E towards the arrow which will cause the nut D to sli...

Page 15: ...YMBOL OPTION FUNCTION BATTERY VOLTAGE 3 0 V 3 7 V Select the battery voltage NETWORK OFF Enable or disable the Wi Fi hotspot Hotspot CONTRAST 5 Levels of contrast Adjust the image contrast BRIGHTNESS 5 Levels of brightness Adjust the image brightness SCENE MODE Recognition Switch between the Recognition mode and Jungle mode Jungle PIP UP Left Center UP Right Off Enable or disable the PIP function ...

Page 16: ...t the automatic shutdown time LANGUAGE 17 Languages Select the language of interface TRAJECTORY 5 Profiles One shot zero correction TIME SYNC Time Format Time Date Set the time and date OSD ON Enable or disable OSD OFF MEASURE 0 8 m 1 2 m 1 8 m 3 0 m Target Height Enter distance measurement mode HOT TRACKING OFF Enable disable hot spot mark marking the spot of highest temperature ON 2 2 2 BATTERY ...

Page 17: ... item and press button to adjust the image contrast You can select one of five levels of the contrast 2 2 5 BRIGHTNESS ADJUSTMENT 1 Hold button to show the menu 2 Select Brightness menu item and press button to adjust the brightness In White Hot mode you can select one of five levels of the brightness to adjust the image lighter or darker In Black Hot mode the brightness of the image turns in the ...

Page 18: ...r 4 seconds to display or hide the reticle 1 Hold button to show the menu 2 Select Reticle menu item A reticle shows in the center of the view 3 Press or buttons to select one of 5 reticle type Then press button to confirm NOTE The scale intervals of the Reticle 4 changes synchronously under the current digital zoom The value of one scale interval of the Reticle 4 is 6 75 MOA You can boresight the...

Page 19: ...display 1 Hold button to show the menu 2 Select FFC menu item and press button to switch the FFC mode Auto The riflescope performs FFC automatically when switching on or rebooting the camera Manual Press button in live view to correct the non uniformity of display External Cover the lens cap then press button in live view to correct the non uniformity of display 3 Hold button to confirm the settin...

Page 20: ...button to show the menu 2 Select Burn Prevention menu item and press button to turn on or turn off the Burn Prevention function 3 Hold button to exit 2 2 14 VIEW DEVICE INFORMATION 1 Hold button to show the menu of device 2 Select Version menu item and press button You can view the device information such as firmware version and serial number 2 2 15 RESTORE DEVICE You can reset the settings of dev...

Page 21: ...then press or buttons to adjust the distance between the target and the device 2 Press button to save the distance settings 4 Set the crosshair position of trajectory correction 1 Aim the big crosshair at the target 2 Shot and mark the actual drop point of the bullet 3 Press and buttons to move the small cursor to the position of the actual drop point You can view the coordinate of the cursor in t...

Page 22: ... hand and the position steady Otherwise the accuracy may be affected 1 Hold button to show the menu 2 Select menu item and press button to enter the Distance Measurement mode 3 Press button to go to the target setting interface 1 Press or to select the target from Wolf 0 8 m Bear 3 0 m Deer 1 2 m and Custom 1 8 m Each target preset can be modified from 0 1 to 9 9 m 2 Set the target and press butto...

Page 23: ...OTE The device password is set by user at first activation If the password was lost or forgotten it can be reset To make a reset provide the following action 1 When the riflescope is turned on hold button to activate the OSD menu 2 Select menu item and press button to restore all parameters to default settings 1 Run the app and connect the phone or tablet with the device 2 If the device is inactiv...

Page 24: ...E CAUTION Thoroughly dry each item before placing them into the storage case To prepare the riflescope for extended storage 1 Clean the riflescope and accessories 2 Place all items into the storage case 3 1 3 UPGRADE DEVICE WARNING Please remove the batteries from the battery compartment before connecting the device to your PC or it may cause computer damage If you removed the batteries please mak...

Page 25: ... Batteries are dead Replace the batteries 3 Batteries surfaces or contacts are dirty or corroded Clean the contact The scope shut off sometimes after shot 1 Wrong battery voltage The default is 3 0 V If you use 3 7V battery switch it in the menu 2 Improper dimension of the battery Check if there is the rubber ring attached on the battery compartment 3 Low battery level Check the remaining capacity...

Page 26: ... from the mishandling abuse misuse improper storage or improper operation of the device including use in conjunction with equipment that is electrically or mechanically incompatible with or of inferior quality to the product as well as failure to maintain the environmental conditions specified by the manufacturer This warranty is extended only to the original purchaser Any breach of this warranty ...

Page 27: ...ur sales receipt to AGM Global Vision s service center at the address listed above All merchandise must be fully insured with the correct postage AGM Global Vision will not be responsible for improper postage or merchandise that becomes lost or damaged during shipment When sending product back please clearly write the RMA on the outside of the shipping box Please include a letter that indicates yo...

Page 28: ... 950 m 1 250 m Eye Relief 45 mm 45 mm Monitor 1024 768 0 39 inch OLED 1024 768 0 39 inch OLED FFC Flat Field Correction Auto Manual External Correction Auto Manual External Correction Palettes Black Hot White Hot Red Hot Fusion Black Hot White Hot Red Hot Fusion Highest Temperature Spot Tracking Yes Yes Scene Mode Jungle Recognition Jungle Recognition Reticle 5 types 4 colors on off 5 types 4 colo...

Page 29: ...two RCR123 up to 4 2V rechargeable batteries Battery Operating Time Up to 4 5 hours continuous running 25 C WiFi off Up to 4 5 hours continuous running 25 C WiFi off Battery Capacity Display Yes Yes Power 5 VDC 2 A USB Type C interface 5 VDC 2 A USB Type C interface Working Temperature 20 C to 55 C 4 F to 131 F 20 C to 55 C 4 F to 131 F Protection Level IP67 IP67 Drop Test Height 1 5 m 4 9 feet 1 ...

Page 30: ...AGM Global Vision 30 NOTES ...

Page 31: ......

Page 32: ...E 173 West Main Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 35 988 412 5573 info agmglobalvision eu www agmglobalvision eu ...