background image

AGM Global Vision

16

NOTE:

Different models of front adapters may have different designs. Refer to the 

user manual for your adapter for correct installation.

Install the Rattler TC on the lens of a day scope as follows (refer to Figure 2-7):
1. Turn the lever (A) of adapter (B) backwards to loosen the adapter clamping 

device. 

2. Slide the Rattler TC with the adapter onto the lens of the day scope (C) as far 

as it goes.

3. Affix the clip-on to the day scope by locking the lever (A) of adapter.
4. Rotate the clip-on to align its vertical position. Tighten the lock nut (D) tightly 

with the special wrench to secure the position.

5. Verify that the clip-on is firmly secured to the day scope. 

NOTE:

AGM recommends that you use an eyecup on the day scope’s eyepiece for 

maximum safety and comfort, as well as to escape detection.

2.1.16  INSTALLING THE RATTLER ON A PICATINNY/WEAVER RAIL

Use the optional quick release mount (QR mount) to install the Rattler TC on a 

Picatinny/Weaver rail. The mount can be attached to the scope with two screws 

(Figure 2-8).

FIGURE 2-7. CLIP-ON INSTALLATION

LOCK

LOCK

D

C

B

UNLOCK

ALIGN

A

FIGURE 2-8. QUICK RELEASE MOUNT INSTALLATION

Summary of Contents for RATTLER TC19-256

Page 1: ...USER MANUAL RATTLER TC19 256 THERMAL IMAGING CLIP ON...

Page 2: ...Export Administration Regulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred con...

Page 3: ...eceiver is connected Consult the dealer or an experienced radio TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules Operation is subject to the following two condi...

Page 4: ...nents 8 1 3 Optional Equipment 8 1 4 Key Features 9 2 OPERATING INSTRUCTIONS 10 2 1 Basic Operations 10 2 2 Main Function 19 2 3 Client Software Introduction 26 3 MAINTENANCE 27 3 1 Maintenance 27 3 2...

Page 5: ...ible to take full advantage of this generous eye relief With hard recoiling rifles serious injury or even death can result from eyepiece impact with the shooter during the recoil process when discharg...

Page 6: ...batteries every two to three months WARNING When carrying or transporting the device put the protective lens cap on WARNING Condensation can cause fogging of the optical surfaces Condensation occurs w...

Page 7: ...ness fog smoke dust rain snow wood camouflage etc The product is mainly applied to scenarios such as patrolling hunting etc The Rattler TC19 256 can easily be attached in front of rifle scopes with ma...

Page 8: ...y items in Figure 1 2 TABLE 1 2 STANDARD COMPONENTS ITEM DESCRIPTION QUANTITY 1 Rattler Thermal Imaging Clip On system 1 2 Objective Lens Cap 1 3 USB Cable 2 4 Lens Tissue 1 5 User Manual 1 6 Carrying...

Page 9: ...EATURES Quick conversion of daytime optics into thermal imaging scope Mounts in front of any daytime scope no re zeroing is required 12 m 35 mK NETD high sensitivity detector 256 192 thermal resolutio...

Page 10: ...r use Clean all optical surfaces with a lens tissue 2 1 2 BATTERIES INSTALLATION CAUTION Verify that the equipment is OFF before remove the batteries To install the batteries refer to Figure 2 1 1 Tur...

Page 11: ...nnecting the device to your PC or it may cause computer damage 1 Open the cable interface cover 2 Connect the device and power adapter with a Type C cable to power on the device Alternatively connect...

Page 12: ...n menu 2 1 6 POWER ON AND OFF Power On Hold the POWER button for 4 seconds to power on the device An image will appear on the display Refer to the figure below for the main view of the clip on display...

Page 13: ...dures see Part 2 2 Main Functions 2 1 9 PALETTE SETTINGS You can select different palettes to display the same scene in different effects Press button in the view mode to switch palettes TABLE 2 2 PAL...

Page 14: ...PC or it may cause computer damage 1 Before connecting the thermal clip on to a computer please make sure that the Wi Fi function of the clip on is disabled 2 Connect the thermal clip on to your PC wi...

Page 15: ...rms with heavy dynamic recoil 308 Win or stronger NOTE The Rattler TC cannot be attached to scopes that include focus rings on the housing of the objective lens NOTE The adapter must fit with the diam...

Page 16: ...A of adapter 4 Rotate the clip on to align its vertical position Tighten the lock nut D tightly with the special wrench to secure the position 5 Verify that the clip on is firmly secured to the day sc...

Page 17: ...see note below Much like when the cam E is released backward moving spring will cause the nut D to slide back into its hole NOTE The eight sided nut of the mount lever cam lock will only fit into thei...

Page 18: ...scene mode and FFC Flat Field Correction to display the best image effect For more information on operational setting procedures see Part 2 2 Main Functions 2 1 18 EYEPIECE REPLACEMENT The device can...

Page 19: ...E 2 4 MENU FUNCTION MENU ITEM SYMBOL OPTION FUNCTION BATTERY VOLTAGE 3 0 V 3 7 V Select the battery voltage NETWORK OFF Enable or disable the Wi Fi hotspot Hotspot CONTRAST 5 Levels of contrast Adjust...

Page 20: ...zero correction TIME SYNC Time Format Time Date Set the time and date OSD ON Enable or disable OSD OFF MEASURE 0 8 m 1 2 m 1 8 m 3 0 m Target Height Enter distance measurement mode HOT TRACKING OFF En...

Page 21: ...ghtness menu item and press button to adjust the brightness In White Hot mode you can select one of five levels of the brightness to adjust the image lighter or darker In Black Hot mode the brightness...

Page 22: ...to move image in vertical direction While using the Image Calibration the display shows value of axis X horizontal and Y vertical ne step of image calibration means 0 25 mil 0 86 MOA 2 49 cm at 100 m...

Page 23: ...function can correct the defective pixels on the screen which have not performed as expected Before you start switch the palette to White Hot mode 1 Hold button to show the menu 2 Select DPC menu ite...

Page 24: ...sh Finnish Hungarian Italian Polish Portuguese Romanian Slovak Spanish 3 Hold button to save settings and exit 2 2 17 TIME SYNCHRONIZATION You can display the date and time on the screen 24 hour and 1...

Page 25: ...he target 5 Align the center of bottom mark with the edge of target bottom Press The left top of the image displays the distance measurement result and the height of the target NOTE Go to distance mea...

Page 26: ...to activate the OSD menu 2 Select menu item and press button to restore all parameters to default settings 1 Run the app and connect the phone or tablet with the device 2 If the device is inactivated...

Page 27: ...D STORAGE CAUTION Thoroughly dry each item before placing them into the storage case To prepare the clip on for extended storage 1 Clean the clip on and accessories 2 Place all items into the storage...

Page 28: ...dead Replace the batteries 3 Batteries surfaces or contacts are dirty or corroded Clean the contact The Rattler TC shut off sometimes after shot 1 Wrong battery voltage The default is 3 0 V If you us...

Page 29: ...sult from the mishandling abuse misuse improper storage or improper operation of the device including use in conjunction with equipment that is electrically or mechanically incompatible with or of inf...

Page 30: ...ceipt to AGM Global Vision s service center at the address listed above All merchandise must be fully insured with the correct postage AGM Global Vision will not be responsible for improper postage or...

Page 31: ...ture Spot Tracking Yes Standby Mode Yes Built in Storage 16 GB EMMC Record Video On board video recording Capture Snapshot Yes CVBS Output Yes via USB Battery Type Two CR123A 3V Lithium or two RCR123...

Page 32: ...73 West Main Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE 6 Andrey Lyapchev Blvd Sofia P C 1756 Bulgaria Tel 35 988...