background image

 
  

 

 

8

 

                                                                                                                                        

  

 

 

X

Y

Starting up the instrument 

 
Place the instrument on a tripod in a horizontal position. Turn the 
laser on with the Power Button button..  
 
 
In the display a flashing level bubble is shown as long as the 
laser is self levelling. When this is finished the symbol turns off. 
The actual rotation speed and the battery condition are shown 
in the display. 
 
 
 
 
 
In this mode without an entered grade, the MRS/Windy function can 
be activated. This decreases the sensitivity against vibrations i.e. by 
wind.

 

 

 

  

 

Entering a grade

 

 

To enter a grade press the X/Y button 
The instrument switches to the grade mode and the last used values 
are shown in the display. 

When the work has to be done with these values, just wait until the 
instrument has self levelled.  
To change the grade values press again the X/Y button. The x% is 
flashing and the grade can be changed with the arrow keys 
between –10% and +10%. To set the grade fast to zero; press 
both arrow keys simultaneously.   
Now the grade can be entered in the Y direction. Pressing 
the X/Y button again enters this value and the instrument 
starts to self level. When the grade is reached the rotation 
of the heads starts. 
In the grade mode it is not possible to activate the 
MRS/Windy mode.  
 

Summary of Contents for GradoPlane 15

Page 1: ...GradoPlane 15 Operator s Manual Operation Instructions Mode d emploi Istruzioni per l uso...

Page 2: ...ument 8 Entering a grade 8 Tilt Function 9 Rotation speed 9 Mask mode 9 Scan Mode 9 Manual Mode 10 Operation with the remote control 10 Change of batteries of the remote control 10 Special functios 11...

Page 3: ...k with machine control units with rotation speed of 600 and 800 RPM The GradoPlane 15 instrument is waterproof and can be used outside in the elements An optional radio remote control is offered that...

Page 4: ...tention Do not disassemble the instrument Inappropriate repairs can cause hazardous laser radiation Only AGL certified service centers are entitled to repair these products In the case of inappropriat...

Page 5: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV te...

Page 6: ...hown while the charging procedure is active If the charging is finished the battery shows three full blocks The instrument has a charge controller inside so not to overcharge if the unit is not monito...

Page 7: ...against vibrations in the Display MRS motion resistant system is shown Enters a grade in X and Y direction X Y button press once for X direction press again for entering the Y value Indications in the...

Page 8: ...ade To enter a grade press the X Y button The instrument switches to the grade mode and the last used values are shown in the display When the work has to be done with these values just wait until the...

Page 9: ...the rotation button The laser spot then can be moved with the arrow keys Mask mode In the mask mode the laser beam can be switched off in different sections This function is used to avoid interferenc...

Page 10: ...opped in grade mode Tilt control the X Y and rotation button can be pressed simultaneously for 2 seconds to confirm and restart the laser If a V and three bars are shown there is no communication with...

Page 11: ...Programm Version z B b 0709 12 1 3 Display Serial Number Press button for next step in the menu Rotation speed Max RPM Display 600 or 800 With Arrow keys choose max RPM 600 or 800 Button to store and...

Page 12: ...rial number Display e g 135350 4 x Software Version Display e g 600527 5 x Com channel Display CH 1 17 With Arrow keys choose 0 to 17 FB2 default setting channel 1 Button to store and change to next m...

Page 13: ...d Safety information Proper use The instrument is for aligning in the desired direction and the grade The instrument is used with a rechargeable NiMH battery The control of the instrument can be done...

Page 14: ...14 Positions of laser warning labels JCS1 JCS2...

Page 15: ...rking temperature 14 F 122 F 10 C 50 C Rotations speed 0 600 800 RPM Battery NiMH battery 12V DC current with optional cable Working hours 20 h Charging time maximum 5 hours Protection class IP67 wate...

Page 16: ...pment The user is responsible for the regular checking of the instrument by the manufacturer or one of its authorized service center A calibration interval of one year is recommended The manufacturer...

Reviews: