13
Checking the calibration
The laser instrument should be checked, like all measure instruments, before use.
The inspection can be carried out most easily by doing a reverse measurement.
Therefore do the following steps:
Set up the instrument onto a stable fixing.
Turn the laser on and let it level.
Mount the receiver in a fixed distance, i.e. at 100’ (30 m), and move it onto the
laser plane (display middle).
Now turn the instrument around each 90° and let the instrument level.
Measure in each case the difference to the first height.
If the deviation is smaller than ±1/16” (± 2mm), the instrument is within the
specification.
In case of larger deviations the instrument has to be calibrated.