 U1701A Quick Start Guide

The Agilent U1701A is safety-certified in compliance with the
following safety and EMC requirements:

IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition)

CISPR 11:2003+A1:2004

IEC 61000-4-2:1995+A1:1998 +A2:2000 

IEC 61000-4-3:2006

IEC 61000-4-4:2004

IEC 61000-4-5:2005

IEC 61000-4-6:2003+A1:2004+A2:2006 

IEC 61000-4-11:2004

Canada: ICES-001:2004

Australia/New Zealand: AS/NZS CISPR11:2004

Safety Notices

C A U T I O N

CAUTION

 notice denotes a hazard. It calls attention to an

operating procedure, practice, or the like that, if not correctly
performed or adhered to, could result in damage to the prod-
uct or loss of important data. Do not proceed beyond a 

CAU-

TION

 notice until the indicated conditions are fully

understood and met.

WA R N I N G

WARNING notice denotes a hazard. It calls attention to an
operating procedure, practice, or the like that, if not cor-
rectly performed or adhered to, could result in personal
injury or death. Do not proceed beyond a WARNING notice
until the indicated conditions are fully understood and met.

Safety Symbols

Direct current

Alternating current

Three-phase alternating current

Both direct and alternating current

Earth (ground) terminal

Equipotentiality

Caution, hot surface

Off (supply)

On (supply)

Protective conductor terminal

Caution, risk of electric shock

Out position of a bi-stable control

In position of a bi-stable control

Frame or chassis terminal

Equipment protected throughout by 
double insulation or reinforced 
insulation

Caution, risk of danger (refer to this 
manual for specific Warning or Caution 
information

Safety Information

Summary of Contents for U1701A

Page 1: ...Agilent Technologies Agilent U1701A Dual Display Handheld Capacitance Meter Quick Start Guide...

Page 2: ...he indicated conditions are fully understood and met WARNING WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not cor rectly performed or adher...

Page 3: ...pacitance of more than 1000 F first discharge the capacitor then select a suitable range to measure it This will shorten the measuring time to achieve an accurate value Degradation of some product spe...

Page 4: ...out of HI limit 13 Audible alert for tolerance and compare mode 5 Auto power off indicator 14 Unit for tolerance display 6 Tolerance mode to set 1 5 10 and 20 for sorting capacitance 15 Unit for Beepe...

Page 5: ...ARD Guard terminal 4 Compare mode 5 TOL Tolerance mode 6 REL Relative mode 7 HOLD SAVE Data hold To store the setting value into the memory 8 RANGE AUTO Manual range Auto range 9 HI LO High Low limits...

Page 6: ...n respectively to indicate which value is being displayed Press momentarily To exit the recording mode Press for more than 1 s To enable relative function Relative function shows the difference betwee...

Page 7: ...ditions After setting the recording mode After setting the compare mode Display showing either OL or below 10 counts Press momentarily To exit tolerance mode Press and hold for more than 1 s To enable...

Page 8: ...t The following buttons will be used for this setting mode a To select which digit to be adjusted b To increase or decrease the current digit s value c To select High or Low limit to be set d To store...

Page 9: ...ocedures are followed 1 Press Left or Right to select the menu item to be set 2 Press Up or Down to change the parameter 3 Press to select the digit to be adjusted the selected digit will flash 4 Pres...

Page 10: ...7 bits Stop bit is always 1 bit Echo oFF Echo on or oFF Prnt oFF Print on or oFF beep 4800 Driving frequency 4800 2400 1200 600 Hz oFF To disable beep LbUt oFF Lock buttons oFF Enable keypad on Disab...

Page 11: ...Battery type Alkaline ANSI NEDA 1604A IEC 6LR61 Power consumption 5 6 mA Battery operation Battery life 80 hours without backlight based on new alkaline Operating temperature 0 C to 50 C Storage tempe...

Page 12: ...t Range Resolution Accuracy The accuracy is specified to measure film capacitor or better and use relative mode to zero residual first Measuring rate as full scale approx 1000 0 pF 0 1 pF 1 10 5 times...

Page 13: ...U1701A Quick Start Guide 12...

Page 14: ...fax 800 829 4433 Canada tel 877 894 4414 fax 800 746 4866 China tel 800 810 0189 fax 800 820 2816 Europe tel 31 20 547 2111 Japan tel 0120 421 345 Korea tel 080 769 0800 fax 080 769 0900 Latin America...

Reviews: