Introduction
The N2792A 200 MHz and N2793A 800 MHz differential probes provide the
superior high- speed differential signal probing required by today’s
high- speed power measurements, automotive bus measurements, and
high- speed digital system designs. The N2792A and N2793A probes offer a
10:1 attenuation ratio, allowing them to be used for a broad range of
applications. These differential probes have an input resistance of 1 M
W
(N2792A) and 200 k
W
(N2793A) and both feature low input capacitance to
minimize circuit loading (7 pF for N2792A and 2 pF for N2793A). The
N2792A and N2793A probes are compatible with any oscilloscope equipped
with 50
W
BNC inputs. They can be powered by any USB port on your
oscilloscope or computer, or by an internal battery (one 9V battery
included with each probe).
Figure 1
Probes (Accessories Not Shown)
Oscilloscope Compatibility
To be compatible with the N2792A and N2793A probes, the oscilloscope
must have a 50
Ω
input and be ground referenced.