Using Smart Test and SignalWizard
6
Transmission Test Set Quick Reference Guide
63
Understanding SignalWizard Overview Window
Signal Viewer
Displays the detected signal. If a J0 trace message is detected
this is also displayed (both 16- and 64-byte message formats
are supported).
Overhead Viewer
Displays results information associated with the overhead
layer of the signal, including:
•
Synchronization status message (decoded S1 byte)
•
CV-S (RS-BIP), CV-L (MS-BIP) and REI-L (MS-REI) error
status
•
AIS-L (MS-AIS) and RDI-L (MS-RDI) alarm status
(LOS and LOF alarms are displayed on the instrument’s front
panel LEDs.)