The condition for moving from one jitter amplitude step to the next can
be set to
•
numbers of received bits and errors
•
a confidence level
Additionally, a relax time can be specified.
Number of Received Bits or Errors
When numbers of received bits or errors are enabled, the measurement
proceeds with the next frequency as soon as one of the two numbers is
reached.
But we are often dealing with very small tolerable bit error ratios, 10
–
12
and below. Measuring such a bit error ratio precisely (and just for one
single point) takes time. Therefore, the measurement provides the
option to set a confidence level.
Confidence Level
The Jitter Tolerance Compliance measurement offers the option to set
a level of confidence. This approach is based on statistics.
Statistics tell us, for example, that if we receive 3 × 10
12
bits without any
error, the probability that the BER is below 10
–12
is higher than 95 %. If
an error occurred, more bits must be compared to achieve the same
confidence level. For details see
“Explanation of the Fast Total Jitter
The measurement proceeds with the next frequency and jitter
amplitude as soon as the desired level of confidence is reached. Setting
a confidence level ensures that neither too few nor too many bits are
captured.
Relax Time
Before the measurement proceeds to the next frequency bin, a
measurement settling or relax time can be applied.
This allows the DUT to recover in case it has lost synchronization due
to an excessive high bit error rate. The next BER measurement starts
after this time has elapsed.
Jitter Tolerance Tests
7
Agilent J-BERT N4903 High-Performance Serial BERT
355
Summary of Contents for J-BERT N4903
Page 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Page 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Page 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Page 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Page 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Page 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Page 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...