Notices

© Agilent Technologies, Inc. 2020

No part of this manual may be reproduced in 
any form or by any means (including elec-
tronic storage and retrieval or translation into 
a foreign language) without prior agreement 
and written consent from Agilent Technolo-
gies, Inc. as governed by United States and 
international copyright laws.

Manual Part Number

G6011-90110

Edition

Second edition, April 2020
Printed in USA
Agilent Technologies, Inc.

2850 Centerville Rd 

Wilmington, DE 19808

USA

Warranty

The material contained in this document is 
provided “as is,” and is subject to being 
changed, without notice, in future editions. 
Further, to the maximum extent permitted by 
applicable law, Agilent disclaims all warran-
ties, either express or implied, with regard to 
this manual and any information contained 
herein, including but not limited to the implied 
warranties of merchantability and fitness for 
a particular purpose. Agilent shall not be lia-
ble for errors or for incidental or consequen-
tial damages in connection with the 
furnishing, use, or performance of this docu-
ment or of any information contained herein. 
Should Agilent and the user have a separate 
written agreement with warranty terms cov-
ering the material in this document that con-
flict with these terms, the warranty terms in 
the separate agreement shall control.

Technology Licenses 

The hardware and/or software described in this 
document are furnished under a license and 
may be used or copied only in accordance with 
the terms of such license.

Restricted Rights Legend

U.S. Government Restricted Rights. Software 
and technical data rights granted to the federal 
government include only those rights custom-
arily provided to end user customers.  Agilent 
provides this customary commercial license in 
Software and technical data pursuant to FAR 
12.211 (Technical Data) and 12.212 (Computer 
Software) and, for the Department of Defense, 
DFARS 252.227-7015 (Technical Data -Com-
mercial Items) and DFARS 227.7202-3 (Rights 
in Commercial Computer Software or Com-
puter Software Documentation).

Safety Notices

CAUTION

A CAUTION notice denotes a 

hazard. It calls attention to an 
operating procedure, practice, or the 
like that, if not correctly performed 
or adhered to, could result in 
damage to the product or loss of 
important data. Do not proceed 
beyond a CAUTION notice until the 
indicated conditions are fully 
understood and met. 

WARNING

A WARNING notice denotes a 
hazard. It calls attention to an 
operating procedure, practice, or the 
like that, if not correctly performed 
or adhered to, could result in 
personal injury or death. Do not 
proceed beyond a WARNING notice 
until the indicated conditions are 
fully understood and met.

Summary of Contents for G6011B

Page 1: ...Agilent G6011B Quiet Cover MS User Manual...

Page 2: ...on flict with these terms the warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may b...

Page 3: ...reparation 11 2 Installation Installing the Oil Tray 13 Accommodating a KF40 Foreline Pump Intake Flange 14 Installing the Rough Pump Inside the Quiet Cover MS 15 Connecting the Power Supply 18 Verify...

Page 4: ...pumps Your rough pump fits in the Quiet Cover MS to significantly reduce noise while an internal fan ensures that your pump will not overheat There is an easy to use kickstand and a full size oil tra...

Page 5: ...r a quality system registered to ISO 9001 Information The Agilent Technologies Quiet Cover MS meets the following IEC classifications Category II Pollution Degree 2 Class III Quiet Cover MS has been d...

Page 6: ...violates safety standards of design and the intended use of the instrument Agilent Technologies assumes no liability for the customer s failure to comply with these requirements Table 1 lists the saf...

Page 7: ...ure to perform a two person lift may result in personal injury WARNING Never run the pump without also running Quiet Cover MS CAUTION While running Quiet Cover MS Do not block air flow to the fan Do n...

Page 8: ...evision are on separate electrical circuits Make sure that all peripheral devices are also certified Make sure that appropriate cables are used to connect the device to peripheral equipment Consult yo...

Page 9: ...21 for a view of the front panel control Table 2 G6011B Quiet Cover MS contents list Part Quantity Part number Quiet Cover MS 1 G6011B Oil tray 1 G6011 40100 Power supply 1 5188 1164 KF40 Trim ring 1...

Page 10: ...1 Parts Identification Parts Identification Quiet Cover MS User Manual 10 Figure 2 Quiet Cover MS rear view power supply not shown Kickstand Power connection Fan Intake...

Page 11: ...ion Physical dimensions Weight 11 3 kg 25 lbs Dimensions Kickstand up 68 25 44 cm 27 13 5 17 25 inches L W H Power supply AC input voltage 100 to 240 VAC 10 DC output voltage 24 V Output load max 1 25...

Page 12: ...Tray 13 Accommodating a KF40 Foreline Pump Intake Flange 14 Installing the Rough Pump Inside the Quiet Cover MS 15 Connecting the Power Supply 18 Verifying the Installation 19 This chapter describes...

Page 13: ...y You need to install it prior to using the Quiet Cover MS 1 Remove any protective film from the tray 2 Slide the tray into the bottom of the Quiet Cover MS with the deep part of the tray facing the f...

Page 14: ...ng the G6011B Quiet Cover on an MS 40 vacuum pump with a KF25 Foreline Pump intake flange skip this procedure If you are installing the G6011B Quiet Cover on an MS 40 vacuum pump with a KF40 Foreline...

Page 15: ...modate an MS 40 vacuum pump If this revision of pump is being installed no changes are required and the installer can proceed to the next procedure on page 16 If an MS 40S pump is being installed comp...

Page 16: ...6 Locking casters top access panels and main cover 2 To remove the main cover assembly a Open the front access door b Lift the main cover vertically to detach it from the guide pins WARNING A two per...

Page 17: ...able If the support feet do not align with the mounting cup and mounting tabs the rough pump orientation is incorrect Pump should be slightly touching both the motor air duct and the electrical panel...

Page 18: ...perating location unlock the locking casters carefully push the Quiet Cover MS to its operating location and lock the front locking casters WARNING Do not attempt to lift the Quiet Cover MS with the r...

Page 19: ...e Quiet Cover MS 3 Turn the Power Switch to the off position 4 Plug the G6011B Quiet Cover into an external power outlet If the instrument is receiving power the Power Switch Figure 1 should light up...

Page 20: ...Pump Oil 22 Using the Kickstand 24 To operate Quiet Cover MS you will need to Understand the controls and indicators on the front panel Know how to handle temperature alarms and signals Know how to d...

Page 21: ...atuses are normal operating modes If the air flow to the Quiet Cover MS is restricted or if the room temperature is above 35 C 95 F the red status indicator on the front panel lights and the temperatu...

Page 22: ...S 4 Unplug the power supply from the Quiet Cover MS 5 Lock the locking casters to secure the Quiet Cover MS 6 Open the front access door of the Quiet Cover MS 7 Tilt the Quiet Cover MS by using the ki...

Page 23: ...ironmental guidelines 12 Return the Quiet Cover MS to its untilted position See Using the Kickstand on page 24 13 Reinsert the oil tray 14 Remove the oil fill plug Figure 12 and refill the pump Figure...

Page 24: ...Quiet Cover MS is on a level surface 2 Lock the two locking casters located on the front of the Quiet Cover MS Figure 14 3 Release the kickstand from the retaining clip Figure 15 Figure 14 Locking cas...

Page 25: ...the floor when Quiet Cover MS is tilted To return Quiet Cover MS to the untilted position 1 Grasp the back of the Quiet Cover MS and gently push the Quiet Cover MS forward off the kickstand To avoid...

Page 26: ...ump oil does not drain completely Be sure the kickstand is down with the bar sitting flat on the floor If so refer to the rough pump documentation for more information Green LED does not light Check t...

Page 27: ...www agilent com Agilent Technologies Inc 2020 Second edition April 2020 G6011 90110 G6011 90110...