Agilent Technologies E1300B Installation Note Download Page 3

Certification

Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory.  Agilent Tech-
nologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Tech-
nology (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration
facilities of other International Standards Organization members.

Warranty

This Agilent Technologies product is warranted against defects in materials and workmanship for a period of one year from date of
shipment.  Duration and conditions of warranty for this product may be superseded when the product is integrated into (becomes a part
of) other Agilent products.  During the warranty period, Agilent Technologies will, at its option, either repair or replace products which
prove to be defective.

For warranty service or repair, this product must be returned to a service facility designated by Agilent Technologies.  Buyer shall pre-
pay shipping charges to Agilent and Agilent shall pay shipping charges to return the product to Buyer.  However, Buyer shall pay all
shipping charges, duties, and taxes for products returned to Agilent from another country.

Agilent warrants that its software and firmware designated by Agilent for use with a product will execute its programming instructions
when properly installed on that product.  Agilent does not warrant that the operation of the product, or software, or firmware will be un-
interrupted or error free.

Limitation Of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied prod-
ucts or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or im-
proper site preparation or maintenance.

The design and implementation of any circuit on this product is the sole responsibility of the Buyer.  Agilent does not warrant the
Buyer’s circuitry or malfunctions of Agilent products that result from the Buyer’s circuitry.  In addition, Agilent does not warrant any
damage that occurs as a result of the Buyer’s circuit or any defects that result from Buyer-supplied products.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED.  Agilent SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Exclusive Remedies

THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES.  Agilent SHALL NOT BE LIABLE
FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CON-
TRACT, TORT, OR ANY OTHER LEGAL THEORY.

Notice

The information contained in this document is subject to change without notice.  Agilent Technologies MAKES NO WARRANTY OF
ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  Agilent shall not be liable for errors contained herein or
for incidental or consequential damages in connection with the furnishing, performance or use of this material.  This document contains
proprietary information which is protected by copyright.  All rights are reserved.  No part of this document may be photocopied, repro-
duced, or translated to another language without the prior written consent of Agilent Technologies, Inc.  Agilent assumes no responsibil-
ity for the use or reliability of its software on equipment that is not furnished by Agilent.

U.S. Government Restricted Rights

The Software and Documentation have been developed entirely at private expense.  They are delivered and licensed as "commercial
computer software" as defined in DFARS 252.227- 7013 (Oct 1988), DFARS 252.211-7015 (May 1991) or DFARS 252.227-7014 (Jun
1995), as a "commercial item" as defined in FAR 2.101(a), or as "Restricted computer software" as defined in FAR 52.227-19 (Jun
1987)(or any equivalent agency regulation or contract clause), whichever is applicable.  You have only those rights provided for such
Software and Documentation by the applicable FAR or DFARS clause or the Agilent standard software agreement for the product in-
volved.

Agilent E1300B/E1301B Mainframes and E1306A Command Module

Memory Module Installation Note

Edition 2 Rev 2

Copyright © 1995-2006 Agilent Technologies, Inc. All Rights Reserved.

iii

Summary of Contents for E1300B

Page 1: ...1306A Command Module Memory Module Installation Note Copyright Agilent Technologies Inc 1995 2006 E1300 90027 E1300 90027 E0206 Manual Part Number E1300 90027 Microfiche Part Number E1300 99027 Printe...

Page 2: ......

Page 3: ...ilent products that result from the Buyer s circuitry In addition Agilent does not warrant any damage that occurs as a result of the Buyer s circuit or any defects that result from Buyer supplied prod...

Page 4: ...e equipment switched off To avoid dangerous electrical shock DO NOT perform procedures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it...

Page 5: ...stem Before you perform any procedures in this guide disconnect AC power and field wiring from the mainframe Caution Do not install or remove modules with power applied to the mainframe Doing so may d...

Page 6: ...ation Procedure Step 1 Disconnect the mainframe s power Remove with Phillips or Pozi drive Screwdriver Step 2 Remove the mainframe s side handles 1 2 Installing Memory into an Agilent E1300B E1301B Ma...

Page 7: ...Slide the top cover toward the rear lift and remove the cover Remove with T10 Torx Key Step 3 Remove the Torx screws on the rear of the mainframe Installing Memory into an Agilent E1300B E1301B Mainfr...

Page 8: ...ee Torx screws T10 Torx Screw Spacer T8 Torx Screws Multimeter Front Support Step 5 Remove the screw securing the support bracket Lift the rear of the support bracket to disconnect it from the control...

Page 9: ...Step 8 Remove the three T10 Torx screws securing the controller board Step 7 Remove the multimeter Installing Memory into an Agilent E1300B E1301B Mainframe 1 5...

Page 10: ...s the E1300 has one ribbon cable the E1301 has two cables Push the controller module forward through the front controller support to disconnect it from the J1 connector Remove the controller module 1...

Page 11: ...able 1 1 Memory Module Address Switch Settings Module s being installed Set one module s address to x signifies a Don t Care state Set the other module s address to x signifies a Don t Care state One...

Page 12: ...Step 12 Reassemble the mainframe Step 11 Install the memory module s and fasten with the Torx screws provided 1 8 Installing Memory into an Agilent E1300B E1301B Mainframe...

Page 13: ...ld wiring from the mainframe Caution Do not install or remove modules with power applied to the mainframe Doing so may damage the modules and the mainframe Caution STATIC ELECTRICITY Static electricit...

Page 14: ...If the Agilent E1306A Command Module is installed in a mainframe disconnect power to the mainframe and remove the Command Module Step 2 Remove the Command Module s shield 2 2 Installing Memory into an...

Page 15: ...address switches need to be set for the 1 MByte modules or five Most Significant Bit address switches for the 512 kByte modules Note Ignore any numbering on the switch bank Use the figure above to pro...

Page 16: ...emory module and fasten with two Torx screws Step 5 Optional Install second memory module and fasten with four Torx screws Step 5 Reassemble the Command Module 2 4 Installing Memory into an Agilent E1...