Agilent Technologies E1300B Installation Note Download Page 1

Agilent 75000 SERIES B

E1300B/E1301B Mainframe
E1306A Command Module
Memory Module

Installation Note

Copyright© Agilent Technologies, Inc., 1995, 2006

*E1300-90027*

E1300-90027

E0206

Manual Part Number: E1300-90027
Microfiche Part Number: E1300-99027

Printed: February 2006 Edition 2

Printed in U.S.A.  E0206

Summary of Contents for E1300B

Page 1: ...1306A Command Module Memory Module Installation Note Copyright Agilent Technologies Inc 1995 2006 E1300 90027 E1300 90027 E0206 Manual Part Number E1300 90027 Microfiche Part Number E1300 99027 Printe...

Page 2: ......

Page 3: ...ilent products that result from the Buyer s circuitry In addition Agilent does not warrant any damage that occurs as a result of the Buyer s circuit or any defects that result from Buyer supplied prod...

Page 4: ...e equipment switched off To avoid dangerous electrical shock DO NOT perform procedures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it...

Page 5: ...stem Before you perform any procedures in this guide disconnect AC power and field wiring from the mainframe Caution Do not install or remove modules with power applied to the mainframe Doing so may d...

Page 6: ...ation Procedure Step 1 Disconnect the mainframe s power Remove with Phillips or Pozi drive Screwdriver Step 2 Remove the mainframe s side handles 1 2 Installing Memory into an Agilent E1300B E1301B Ma...

Page 7: ...Slide the top cover toward the rear lift and remove the cover Remove with T10 Torx Key Step 3 Remove the Torx screws on the rear of the mainframe Installing Memory into an Agilent E1300B E1301B Mainfr...

Page 8: ...ee Torx screws T10 Torx Screw Spacer T8 Torx Screws Multimeter Front Support Step 5 Remove the screw securing the support bracket Lift the rear of the support bracket to disconnect it from the control...

Page 9: ...Step 8 Remove the three T10 Torx screws securing the controller board Step 7 Remove the multimeter Installing Memory into an Agilent E1300B E1301B Mainframe 1 5...

Page 10: ...s the E1300 has one ribbon cable the E1301 has two cables Push the controller module forward through the front controller support to disconnect it from the J1 connector Remove the controller module 1...

Page 11: ...able 1 1 Memory Module Address Switch Settings Module s being installed Set one module s address to x signifies a Don t Care state Set the other module s address to x signifies a Don t Care state One...

Page 12: ...Step 12 Reassemble the mainframe Step 11 Install the memory module s and fasten with the Torx screws provided 1 8 Installing Memory into an Agilent E1300B E1301B Mainframe...

Page 13: ...ld wiring from the mainframe Caution Do not install or remove modules with power applied to the mainframe Doing so may damage the modules and the mainframe Caution STATIC ELECTRICITY Static electricit...

Page 14: ...If the Agilent E1306A Command Module is installed in a mainframe disconnect power to the mainframe and remove the Command Module Step 2 Remove the Command Module s shield 2 2 Installing Memory into an...

Page 15: ...address switches need to be set for the 1 MByte modules or five Most Significant Bit address switches for the 512 kByte modules Note Ignore any numbering on the switch bank Use the figure above to pro...

Page 16: ...emory module and fasten with two Torx screws Step 5 Optional Install second memory module and fasten with four Torx screws Step 5 Reassemble the Command Module 2 4 Installing Memory into an Agilent E1...