![Agilent Technologies 9499225 User Manual Download Page 92](http://html1.mh-extra.com/html/agilent-technologies/9499225/9499225_user-manual_2868747092.webp)
Technical Information
RS 232/RS 485 Communication Description
5
MS40+ Single Stage Rotary Vane Pumps User Manual / 87-901-008-01 (
H.00
)
92/104
WIN
TYPE
R/W
DESCRIPTION
206
N
R
ERROR CODE: 128: Rotor blocked; 64: shortcircuit; 32: Undervoltage/Overvoltage;
16: Motor overtemp; 8: Verify line; 4: Controller overtemp; 2: Bus Undervoltage;
1: overcurrent
207
N
R
OUTPUT FREQUENCY [rpm]
216
N
R
CONTROLLER TEMPERATURE [°C]
222
N
R
POWER SUPPLY TEMPERATURE [°C]
225
N
R
OIL LEVEL (0=level ok; Bit 0: underlevel; Bit 1: maintenance)
233
N
R
ROTATIONAL FREQUENCY [rpm]
300
N
R
CYCLE TIME [min]
301
N
R
CYCLE NUMBER
302
N
R
PUMP LIFE [h]
305
N
R
TIME WITH OIL UNDER LEVEL [min]
306
N
R
TIME WITH DIRTY FILTER [min]
307
N
R
TIME CONTROLLER STAND BY
319
A
R
CONTROLLER MODEL NUMBER
320
A
R
PUMP MODEL NUMBER
321
A
R
PUMP SPECIAL MODEL NUMBER
322
A
R
PUMP SERIAL NUMBER
323
A
R
CONTROLLER SERIAL NUMBER
358
N
R
MAINTENACE TIMER [hours]
362
N
R
LAST HOUR TEMPERATURE AVERAGE [°C]
364
N
R
LAST HOUR AVERAGE POWER [W]
365
N
R
LAST HOUR AVERAGE FREQUENCY [Hz]
382
N
R
LAST HOUR AVERAGE TEMPERATURE (°C)
384
N
R
AVERAGE TEMPERATURE DURING PUMP LIFE (°C)
406
A
R
PROGRAM LISTING CODE & REVISION
407
A
R
PARAMETER LISTING CODE & REVISION
503
N
RW
RS485 SERIAL ADDRESS SETTING [0-31]
504
L
RW
SERIAL TYPE SELECT (0=RS232; 1=RS485)