Additional Operating Information
5
Agilent 34945A Microwave Switch/Attenuator Driver Module User’s Guide
105
The schematic shown is similar to the Agilent 876x series of switches and 849x
series of step attenuators.
Figure 5-5. Dual-Coil Switch Connection Diagram (combined position indicators).
Pulsed Actuation Mode
The pulsed actuation mode is set during a bank
preset
. Pulsed mode can also
be set with the command:
ROUTe:CHANnel:DRIVe:PULSe:MODE ON
It is also set when channels are paired either through a bank
preset
or with
the command:
ROUTe:CHANnel:DRIVe:PAIRed:MODE ON
34945EXT
Y1155A
Distribution
Board
Switch
Open Collector
Output Drivers
Logic Gate
Sense
Pull Down
Resistor
Sense
Pull Down
Resistor
Logic Gate
IND 11
+VR
IND 1
+VI
DRV 1
DRV 11
Drive Port 2 –
Drive
Drive Port 1 –
Pivot
Armature
Port 1
Port C
Port 2