1.4.2. Scan options 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
Menu: Tool -> Scan options: 
 
Scan speed 

 (Default is 3 scans/sec). 

● 

Set scan speed, range from 30 scans/sec to 3 scans/sec. 

 
Scan delay time 

 (default is 3 sec standard delay). 

● 

Set scan delay after success read, set range from 0 to 3 times of standard delay. 

 

 

1.4.3 Cam Options 

 

The scanner comes preconfigured for optimal reading. If you find it difficult to read your tubes, you can try to change 
the parameters in the software 

ampcam.exe.

 The different brightness and contrast to better read your tubes 2D 

codes 

 

 

Summary of Contents for QC-15S-Z

Page 1: ...www agilebio com www storage accessories com AgileBio SARL Tel 33 0 1 75 43 06 61 email sales agilebio com 1 User s Quick Guide Single Tube Flat Scanner 2D ref QC 15S Z...

Page 2: ...email sales agilebio com 2 Sommaire Use Description 3 1 1 Installation 3 1 1 2 Driver installation 3 1 2 Install iALinkAp and Activte it 4 1 3 Run a program automatically when Windows starts 6 1 4 Se...

Page 3: ...Download the software on http storage accessories com 1 1 2 Driver installation Insert barcode reader USB interface Open the folder drivers and double click on DRV_UVC_20100202_WHQL If you have windo...

Page 4: ...stall iALinkAp and Activte it Launch iALinkDM icon2 this window will open Click on the button Yes Restart iALinkDM icon2 this windows will open Click on the button OK Insert the USB dongle into the co...

Page 5: ...ilebio com 5 N B Always Start iALinkDM icon2 in Administrator Mode on Windows Vista 7 8 Right click on the program shortcut that you want and select Properties Select Compatibility tab and under Privi...

Page 6: ...em to which you want to create a shortcut Right click the item and then click Create Shortcut The new shortcut appears in the same location as the original item Drag the shortcut into the Startup fold...

Page 7: ...data as WM_COPYDATA to the receive window reference to the Appsample in the sample Receive terminal Send data to current active window set current active window as data receive terminal default Send d...

Page 8: ...m 30 scans sec to 3 scans sec Scan delay time default is 3 sec standard delay Set scan delay after success read set range from 0 to 3 times of standard delay 1 4 3 Cam Options The scanner comes precon...

Reviews: