MAINTENANCE
Some basic maintenance as described in
this chapter can be done by the operator.
For other maintenance jobs or defects the
Agfa authorized repair service dept.
should be called.
Being constructed of the best materials the
processor requires very little maintenance.
However, chemicals, water and film cause
deposits and, therefore, cleaning is the most
essential part of a good maintenance pro-
gramme.
NOTE: To avoid water outlet owing to
leakage of the hose connection,
turn off the water when the processor
is not in use
You should follow these cleaning instructions
in order to obtain optimum processing results
and to keep the processor in good working
order.
In order to avoid algae growth on the rollers
in the wash rack, the wash rack should be
taken out every evening and remounted the
following morning. Furthermore, the wash
tank should be drained every evening. This
will prevent algae growth in the wash tank.
If the processor is left in the standby mode
for a longer period of time, or if it is not in use,
all tanks must be either full or empty in order
to avoid deflections of the partitions between
the wet sections.
CAUTION:
When fresh chemical solutions are
filled in, make sure that all air has been
expelled from all circulation and re-
plenishment pumps and hoses before
the processor is started up. This is to
ensure the circulation of the chemicals
THE PUMPS MUST NOT RUN DRY
AT ANY TIME
Before cleaning procedure is started
switch off all power on the mains outlet
switch
DAILY CLEANING
1) Clean the insertion table.
2) Clean all upper rollers with a damp cloth
using a new cloth for each rack.
3) Clean all guides above the liquid level.
4) Clean the insertion rollers for any chemical
residues and run some cleaning films through
the processor.
WEEKLY CLEANING
1) Remove the dev., fix and wash racks and
clean it thoroughly with warm water (35-40
0
C).
2) Clean all guides.
3) Clean all rollers, gear wheels and bear-
ings.
4) Check that the transport system is working
properly.
CAUTION:
Be careful not to spill any fixer into the
developer when lifting the racks out or
by reinstalling them with a full tank.
Even the slightest amount of fixer will
contaminate the developer
Summary of Contents for Rapiline 135-3
Page 1: ...RAPILINE 51 RAPILINE 51 SP 1 N agfa ra51 SP chapter1 pm5 Introduction...
Page 79: ...Manual del usuario P gina 11 16 E 04 03 96...
Page 101: ...RAPILINE 51 3 RAPILINE 72 3 RAPILINE 95 3 RAPILINE 135 3 I agfa master chap2 gr pm6...
Page 102: ...30 07 96 2 16 GR 1 2 Agfa 3 4 5 Agfa T V Bauart gepr ft...
Page 103: ...3 16 GR 30 07 96 2 4 6 7 13 14 16...
Page 104: ...30 07 96 4 16 GR RC JOG MODE...
Page 105: ...5 16 GR 30 07 96 x MANUAL REPL 100 cc...
Page 111: ...11 16 GR 30 07 96 ON OFF OFF STANDBY SOUND PAN LIGHT Panlight OFF DEV TEMP MAN REPL 100cc...
Page 113: ...13 16 GR 30 07 96 Off line 1 2 3 15 cm 4 5 6 led led PTS PTS min 4 cm...
Page 114: ...30 07 96 14 16 GR 1 2 3 4 10 cm...
Page 115: ...15 16 GR 30 07 96 1 5 6 7 8 9...
Page 116: ...30 07 96 16 16 GR Agfa STANDBY 1 2 3 4 1 35 40 C 2 3 4...
Page 181: ...RAPILINE 3 Pre installation n agfa master chapter3 pm5...
Page 185: ...PRE INSTALLATION 3 05 00 RAPILINE 96 03 13...
Page 215: ...RAPILINE 51 RAPILINE 51 SP SPARE PARTS LIST 4 029 00 96 09 17...