CLEARANCE TO COMBUSTIBLES
The minimum clearance to combustibles required is
650mm to the back and sides, and 800mm to the
front. (See Fig.2)
B
B
A
B
Stove
Heater
Wall
Minimal Distances:
A > 80cm
B > 65cm
Fig 2
SAFE DISTANCE OF CHIMNEYS FROM
FLAMMABLE MATERIALS AND BUILDING
CONSTRUCTIONS
When installing a connecting flue pipe great care
must be taken to ensure that there is no risk of ignit-
ing combustible material, an uninsulated flue pipe
must be installed at least with a clearance of three
times the diameter of the flue pipe, i.e. 150mm flue
pipe requires 450mm clearance from combustibles,
for further information see Building Regulation Part
J.
Where a flue pipe is to be installed without connect-
ing to a chimney (passing through ceiling or
combustible wall) seek guidance on clearances from
combustibles from the manufacturer/supplier of the
flue pipe.