RECOMMENDED FUELS
All fuels should be stored under cover and kept
as dry as possible prior to use.
This appliance has been tested using seasoned
wood logs and manufactured briquetted smokeless
fuel (Ancit) for closed appliances, sized between
20g and 140g. Other fuels are commercially avail-
able and may give similar results. Wood logs up to
330mm long are suitable. All fuels should be stored
under cover and kept as dry as possible prior to use.
Do not use fuels with a Petro-coke ingredient as this
may cause the grate to overheat, causing damage.
Reduced outputs will result when fuels of lower
calorific values are used. Never use gasoline or
gasoline type lantern fuel, kerosene, charcoal lighter
fluid or similar liquids to start or freshen up a fire in
This stove has obtained HETAS Ltd approval for
burning natural and manufactured smokeless fuels
only as detailed in recommended fuels below.
HETAS Approval does not cover the use of other
fuels either alone or mixed with the recommended
fuels listed, nor does it cover instructions for the use
of other fuels.
Fig.10
this heater. Keep all such liquid well away from the
heater at all times. Operate the stove only with the
fuelling door closed except for re-fuelling.
Secondary
Air Control
Primary Air
Control
TECHNICAL DATA
MANUFACTURED SMOKELESS
FUEL
WOOD
Max Output: (kW)
Nominal Output: (kW)
Room
Total
9.0
9.0
5.0
5.0
Room
Total
9.0
9.0
5.0
5.0
Typical refuelling intervals to obtain nominal out-
puts:
MSF
1 hr
WOOD
.75 hr
CO@ 13% oxygen:
0.08%
0.12%
Flue Gas Temperature at nominal output:
306°C
265°C
Gross Weight:
112 Kgs
Flue Outlet Diameter:
125mm
Flue Draught:
12 Pa
Efficiency:
79.5 %
77.6%
Log Size:
N/A
330mm
Flue Gas Mass Flow: (g/s)
3.9
5.1
Energy Efficiency Rating:
N/A
A
Mean C
n
H
m
(at 13 % O
2
) Nmg/m
3
11
117
Mean NOx (at 13 % O
2
) Nmg/m
3
100
91
DIN Plus dust (at 13 % O
2
)s Nmg/m
3
20
22
LIGHTING
Before lighting the stove check with the installer that the installation work and commissioning checks described
previously have been carried out correctly and that the chimney has been swept clean, is sound and free from
any obstructions. As part of the stoves commissioning and handover the installer should demonstrate how to
operate the stove correctly.
LEAVE THE DOOR SLIGHTLY AJAR DURING THE FIRST FIRING TO PREVENT THE ROPE FROM
STICKING TO THE PAINT DURING THE CURING PROCESS.